Valve; w/Stop Valve), Supply/Return Port Size: 03 (3/8), Return Unit Flow Switch Output Specifications: ET (Out 1: PNP; Out 2: Flow Rate: Analog 1 to 5 V ⇔ Analog 1 to 5 V; Temperature Sensor: Yes), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Return Unit Flow Switch Unit Specifications: M (Integrated Display: L/min; Accumulated Flow: L; Temp.: °C; Integrated Display IO-Link: L/min; Accumulated

Valve; w/Stop Valve), Supply/Return Port Size: 04 (1/2), Return Unit Flow Switch Output Specifications: C (Out 1: NPN; Out 2: Flow Rate: Analog 1 to 5 V; Temp.: None; Temperature Sensor: None), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Return Unit Flow Switch Unit Specifications: M (Integrated Display: L/min; Accumulated Flow: L; Temp.: °C; Integrated Display IO-Link: L/min; Accumulated

Valve; w/Stop Valve), Supply/Return Port Size: 03 (3/8), Return Unit Flow Switch Output Specifications: 1 (Out 1: Analog 1 to 5 V; Out 2: Flow Rate: None; Temp.: None; Temperature Sensor: None), Lead Wire: N (w/o Lead Wire and M8 Connector)

Valve; w/Stop Valve), Return Port Size: 04 (1/2), Flow Switch Output Specifications: E (Out 1: PNP; Out 2: Flow Rate: Analog 1 to 5 V; Temp.: None; Temperature Sensor: None), Lead Wire: N (w/o Lead Wire and M8 Connector), Flow Switch Unit Specifications: J (Integrated Display: L/min; Accumulated Flow: L; Temp.: °F)

Valve; w/Stop Valve), Return Port Size: 04 (1/2), Flow Switch Output Specifications: E (Out 1: PNP; Out 2: Flow Rate: Analog 1 to 5 V; Temp.: None; Temperature Sensor: None), Lead Wire: N (w/o Lead Wire and M8 Connector), Flow Switch Unit Specifications: J (Integrated Display: L/min; Accumulated Flow: L; Temp.: °F)

Valve; w/Stop Valve), Return Port Size: 03 (3/8), Flow Switch Output Specifications: CT (Out 1: NPN; Out 2: Flow Rate: Analog 1 to 5 V ⇔ Analog 1 to 5 V; Temperature Sensor: Yes), Lead Wire: N (w/o Lead Wire and M8 Connector), Flow Switch Unit Specifications: M (Integrated Display: L/min; Accumulated Flow: L; Temp.: °C; Integrated Display IO-Link: L/min; Accumulated Flow: L; Temp.: °C

Valve; w/Stop Valve), Return Port Size: 04 (1/2), Flow Switch Output Specifications: E (Out 1: PNP; Out 2: Flow Rate: Analog 1 to 5 V; Temp.: None; Temperature Sensor: None), Lead Wire: N (w/o Lead Wire and M8 Connector), Flow Switch Unit Specifications: J (Integrated Display: L/min; Accumulated Flow: L; Temp.: °F)

Valve; w/Stop Valve), Return Port Size: 04 (1/2), Flow Switch Output Specifications: E (Out 1: PNP; Out 2: Flow Rate: Analog 1 to 5 V; Temp.: None; Temperature Sensor: None), Lead Wire: N (w/o Lead Wire and M8 Connector), Flow Switch Unit Specifications: J (Integrated Display: L/min; Accumulated Flow: L; Temp.: °F)

Valve; w/Stop Valve), Return Port Size: 04 (1/2), Flow Switch Output Specifications: E (Out 1: PNP; Out 2: Flow Rate: Analog 1 to 5 V; Temp.: None; Temperature Sensor: None), Lead Wire: N (w/o Lead Wire and M8 Connector), Flow Switch Unit Specifications: J (Integrated Display: L/min; Accumulated Flow: L; Temp.: °F)

Valve; w/Stop Valve), Return Port Size: 04 (1/2), Flow Switch Output Specifications: E (Out 1: PNP; Out 2: Flow Rate: Analog 1 to 5 V; Temp.: None; Temperature Sensor: None), Lead Wire: N (w/o Lead Wire and M8 Connector), Flow Switch Unit Specifications: J (Integrated Display: L/min; Accumulated Flow: L; Temp.: °F)

Valve; w/Stop Valve), Return Port Size: 04 (1/2), Flow Switch Output Specifications: E (Out 1: PNP; Out 2: Flow Rate: Analog 1 to 5 V; Temp.: None; Temperature Sensor: None), Lead Wire: N (w/o Lead Wire and M8 Connector), Flow Switch Unit Specifications: J (Integrated Display: L/min; Accumulated Flow: L; Temp.: °F)

Valve: None; Stop Valve: None, Return Port Size: 03 (3/8), Flow Switch Output Specifications: 1 (Out 1: Analog 1 to 5 V; Out 2: Flow Rate: None; Temp.: None; Temperature Sensor: None), Lead Wire: N (w/o Lead Wire and M8 Connector)

Valve: None; Stop Valve: None, Return Port Size: 03 (3/8), Flow Switch Output Specifications: CT (Out 1: NPN; Out 2: Flow Rate: Analog 1 to 5 V ⇔ Analog 1 to 5 V; Temperature Sensor: Yes), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Flow Switch Unit Specifications: J (Integrated Display: L/min; Accumulated Flow: L; Temp.: °F)

Valve; w/Stop Valve), Return Port Size: 03 (3/8), Flow Switch Output Specifications: 1 (Out 1: Analog 1 to 5 V; Out 2: Flow Rate: None; Temp.: None; Temperature Sensor: None), Lead Wire: N (w/o Lead Wire and M8 Connector)

Rated Flow Range: 40 (5 to 40 L/min), Flow Adjustment Valve: S (w/Flow Adjustment), Port Size: 04 (TSJ1/2, Compression Fitting), Output Specification/Temperature Sensor: CT (Out 1: NPN; Out 2: Flow Rate Analog 1-5 V; Temperature: Analog 1-5 V; w/Temperature Sensor), Lead Wire: with Lead Wire with M8 Connector, 3 m, Unit Specification: G (Instantaneous Flow: gal/min; Accumulated Flow: gal;

Rated Flow Range: 04 (0.5 to 4 L/min), Flow Adjustment Valve: S (w/Flow Adjustment), Port Size: 03 (TSJ3/8, Compression Fitting), Output Specification/Temperature Sensor: CT (Out 1: NPN; Out 2: Flow Rate Analog 1-5 V; Temperature: Analog 1-5 V; w/Temperature Sensor), Lead Wire: with Lead Wire with M8 Connector, 3 m, Unit Specification: J (Instantaneous Flow: L/min; Accumulated Flow: L; Temperature

Body Size: 4 (1/2), Type: 2 (Elbow), Control Type: 0 (Meter-out), Indicator Direction: 1 (180°), Thread: R, Port Size: 04 (1/2), Width Across Flats: 9mm, Tubing: 12 (ø12)

Body Size: 4 (1/2), Type: 2 (Elbow), Control Type: 1 (Meter-in), Indicator Direction: None (0°), Thread: R, Port Size: 04 (1/2), Width Across Flats: 9mm, Tubing: 12 (ø12)

Body Size: 4 (1/2), Type: 2 (Elbow), Control Type: 1 (Meter-in), Indicator Direction: None (0°), Thread: R, Port Size: 04 (1/2), Width Across Flats: 9mm, Tubing: 16 (ø16)

Body Size: 4 (1/2), Type: 2 (Elbow), Control Type: 1 (Meter-in), Indicator Direction: 3 (270°), Thread: N (NPT), Port Size: 04 (1/2), Width Across Flats: 9mm, Tubing: 11 (ø3/8"), Seal: S (w/Sealant)