Installation 6 4-1 Air Supply 6 4-2 Piping 6 4-3 Shaft Load Limit 6 4-4 Coupling 7 4-5 Operating Environment 8 4-6 Using Body As Flange 8 5. Setting of Rotation Time 9 5-1 Moment of Inertia 9 11 5-2 Kinetic Energy 12 5-3 External Stopper 1314 6. Maintenance and Inspection 1516 7.
Travel to intermediate position 1 Press within 3s after pressing . Travel to intermediate position 2 Press within 3s after pressing . Travel to intermediate position 3 30 6.Setting of speed and acceleration General 3 positions 5 positions General 6-1 Setting of speed By adjustment of switch and , the speed of actuator is set.
1 u !5 !6 !3 !4 o i Without switch !2 @1 @2 w r Description Replaceable kits list Component parts No.
1: The air quality class is according to JIS B 8392-1:2012 [3:6:-] and ISO8573-1:2010 [3:6:-]. 2: When using the accumulated value hold function, calculate the product life from the operating conditions, and use the product within its life.
1 .30 1.42 1.54 250 1 . 1 2 1 . 1 6 '1.18 1 . 2 1 1.24 1 . 2 7 1.30 1 .33 '1.40 1.46 1.53 1 .59 '1.72 1.84 2.O9 2.22 300 1 .58 1.63 1 .66 1 . 7 0 1 . 7 4 1 .78 1.82 1.86 r.95 2.03 2 . 1 2 2.2\ 2.38 2.55 2.84 3.01 400 3.10 3.16 3.20 3.26 3.32 3.44 3.50 \r.o I 3.73 3.97 4.20 4.44 4.67 5 . 1 9 Weight sw Dtype {rbs) 056 0.099 0.104 0 . 1 1 0 0.1 17 0.1230.1300.1340.141 0.154 0 . 1 6 3o.172 0.185
3(R) y t r y t r y t r w q e w q e w q e 3(R) 3(R) 3(R) 1(P) 1(P) 1(P) X X 6 VP500/700-X536 Dimensions Residual Pressure Release Valve (-X536) VP542(R)-5 D YZ1-03 -X536 VP542(R)-5 D YZ1-03 -M -X536 3/8" [2(A) port] Port size: 1/8" (Without check valve) Applicable tube O.D.: 6, 1/4" (With check valve) (External pilot port) 31 2 x 4.2 (For mounting) Safety limit switch Made by OMRON 3.5 7
1 .30 1.42 1.54 250 1 . 1 2 1 . 1 6 '1.18 1 . 2 1 1.24 1 . 2 7 1.30 1 .33 '1.40 1.46 1.53 1 .59 '1.72 1.84 2.O9 2.22 300 1 .58 1.63 1 .66 1 . 7 0 1 . 7 4 1 .78 1.82 1.86 r.95 2.03 2 . 1 2 2.2\ 2.38 2.55 2.84 3.01 400 3.10 3.16 3.20 3.26 3.32 3.44 3.50 \r.o I 3.73 3.97 4.20 4.44 4.67 5 . 1 9 Weight sw Dtype {rbs) 056 0.099 0.104 0 . 1 1 0 0.1 17 0.1230.1300.1340.141 0.154 0 . 1 6 3o.172 0.185
3(R) y t r y t r y t r w q e w q e w q e 3(R) 3(R) 3(R) 1(P) 1(P) 1(P) X X 6 VP500/700-X536 Dimensions Residual Pressure Release Valve (-X536) VP542(R)-5 D YZ1-03l-l-X536 VP542(R)-5 D YZ1-03l-Ml-X536 3/8" [2(A) port] Port size: 1/8" (Without check valve) Applicable tube O.D.: 6, 1/4" (With check valve) (External pilot port) 31 2 x 4.2 (For mounting) Safety limit switch Made by OMRON 3.5
24. 1) 2) 3) 1) 2) 1.5~2 2 2. 2-5. ,AS 8 2-6. 2-6-1.
Fluoropolymer Needle Valve Series LVN Specifications LVN20 LVN30 LVN40 Model Orifice diameter 4.4 4, 6 1/8", 3/16", 1/4" Metric Inch 10 10, 12 3/8", 1/2" 8 6, 8, 10 1/4", 3/8" Tube size Refer to Best Pneumatics No. 7 for further details.
4 $7 $6 y %0 %1 CLS CLQ #3 #2 !8 @0 @2 @1 @7 RLQ @3 r MLU o #5 !6 $3 $4 MLGP Component Parts Component Parts Material No.
D D t D t t c e c c e e u u s u s s d i d i d i g g g o o o n n n r r r P P P A A A 1 1 9 9 9 9 9 9 w w 9 w 9 9 m I m I n n 9 9 9 u d u d a a a r u r u o s o F s tr F i e tr i e 9 9 9 D r r D r r r e e e e v v s 1 d d s 1 1 d o o i i n g n g n n n n a a H H n P n P g g r r o o i i s s d d e e u u D D c c t t d A d A r r w w a a 12-11-1 2 Courtesy of Steven Engineering, Inc.-230 Ryan Way,
10 11 12 16 14 16.5 19.5 24 B 4.5 4 7.5 9.5 9 11.5 14.5 17.5 22 27 W 5.5 6 2.5 0.5 1 1.5 4.5 7.5 12 17 A 5.5 6 10 11 12 16 14 16.5 19.5 24 B 4.5 4 7.5 9.5 9 11.5 14.5 17.5 22 27 W 7.5 8 4.5 2.5 3 0.5 2.5 5.5 10 15 A 12 16 20 25 32 40 50 63 80 100 12 16 20 25 32 40 50 63 80 100 (4) (4.5) (1) (1) (0.5) (3) (6) (9) (13.5) (18.5) 1.5 2 6 7 8 12 10 12.5 15.5 20 Note 1) ( ): For D-A93 type Note
s/2 s/5 s -52No.PF-OMX0007-A 1: The air quality class is according to JIS B 8392-1:2012 [4:6:-] and ISO8573-1:2010 [4:6:-]. 2: When using the accumulated value hold function, calculate the product life from the operating conditions, and use the product within its life.
Default: Gain 9 Bit Bit 3, 2, 1, 0 Value Bit 3 2 1 0 Setting 0 0 0 0 Gain 0 0 0 0 1 Gain 1 0 0 1 0 Gain 2 0 0 1 1 Gain 3 0 1 0 0 Gain 4 0 1 0 1 Gain 5 0 1 1 0 Gain 6 0 1 1 1 Gain 7 1 0 0 0 Gain 8 1 0 0 1 Gain 9 * 1 0 1 0 Gain A 1 0 1 1 Gain B 1 1 0 0 Gain C 1 1 0 1 Gain D 1 1 1 0 Gain E 1 1 1 1 Gain F * indicates the initial shipping value. 16 - Parameter index 0x43 Parameter name Sensitivity
Piping specification: -C4H, -C6H, -N7H, -C4L, -C6L, -N7L First, tighten by hand, then use a wrench appropriate for the hexagon flats of the body to tighten an additional 1/6 to 1/4 turn.
Value 7 6 5 4 3 2 1 0 Value 7 6 5 4 3 2 1 0 Output No. 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0 1 0-7 All clear output Setting value 00 0 0 0 0 0 0 0 0 00 0 0 0 0 0 0 0 0 Output No. 15 14 13 12 11 10 9 8 15 14 13 12 11 10 9 8 2 8-15 All hold last state Setting value FF 1 1 1 1 1 1 1 1 00 0 0 0 0 0 0 0 0 Output No. 23 22 21 20 19 18 17 16 23 22 21 20 19 18 17 16 3 16-23 All force output Setting value
6 !7 !8 !9 Seal kit NBR MHK12-PS MHK16-PS MHK20-PS MHK25-PS CR(2) P3318113 P3318113-1 P3318113-2 P3318205 P3318205-1 P3318205-2 P3318213 P3318213-1 P3318213-2 P3318305 P3318305-1 P3318305-2 P3318313 P3318313-1 P3318313-2 P3318405 P3318405-1 P3318405-2 P3318413 P3318413-1 P3318413-2 P3318105 P3318105-1 P3318105-2 FKM(2) @0 Dust cover Si(2) Note 1) No. !6 to !
Connection thread Proper tightening sizeR,NPT,G torque Nm 1/8 35 1/4 812 3/8 1520 (6) Installation of Connection thread (6)-1 For M5,10-32UNF Tightening method 1/2 2025 First, tighten it by hand, then give it an additional 1/6 turn to 1/4 turn with an appropriate wrench.. Refer to Table below for reference.
1.5 0 40 12 11 7 4.5 0 0.5 3.5 4 0.5 9.5 8.5 4.5 2 1 1.5 0 50 12.5 11.5 7.5 5 0 1 4 4.5 1 10 9 5 2.5 1.5 2 0 63 12.5 11.5 7.5 5 0 1 4 4.5 1 10 9 5 2.5 1.5 2 0 80 15.5 14.5 10.5 8 2.5 4 7 7.5 4 14 13 9 6.5 5.5 6 2.5 100 15.5 14.5 10.5 8 2.5 4 7 7.5 4 14 13 9 6.5 5.5 6 2.5 125 17.5 16.5 12.5 10 6 6 9 9.5 6 17.5 16.5 12.5 10 9 9.5 6 Types without air cushion have different values for auto switch