Types 10, 20 Types 10, 20 VVDW 0 2 C 1 01 2 VVDW 2 0 4A Series Series 1 2 10 20 1 2 10 20 Thread type VC Rc G NPT Nil F N Material VDW C S C37 SUS Type 30 VQ VVCW20-4A OUT port size Stations Symbol M5 01 Port size M5 1/8 (6A) For 2 stations For 3 stations 1 2 VX2 VX Type 10 is M5 only.

(C ) Temp. conditions Power source 1.0 High temp. water (X, E, N, P) 60 40 5 0.82 0.20 0.20 Water (Std.) Oil (D. N) Steam (S,Q) Oil (Std.) VX3235-00 VX3335-00 3 1.1 0.25 0.27 AC DC 60 40 1 99 60 120 183 Maximun VX3245-00 40 1.6 0.20 0.38 4 20 VX3345-00 Minimum AC, DC Ambient temperature (C ) 40 10 Operating fluid temp.

Series VXF Dimensions VXF216 5 0: Solenoid type Grommet: G Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com VXF2280: Solenoid type Grommet: G M Port size Rc Model A B C D E F H J K L N P 3 4 VXF2150 VXF2160 VXF2280 40 48 77 25 33.5 48.5 66 74 110 36 45 63 35.5 40 57

GB 4.1 TECHNICAL FEATURES OF DRYERS SERIES PDE 3 20 -S MODEL PDE3-S PDE5-S PDE8-S PDE10-S PDE15-S PDE20-S Flow rate at 35C 7 bar [l/min] 350 550 850 1100 1800 2300 [m/h] 21 33 51 66 108 138 [Scfm] 12 19 30 39 64 81 Dew point* +37.8F (+3C) equal to 0.73 gr/Nm di H2O Ambient temperature nom (max) [F/C] +100 (+115) / +37.8 (+45) Min. ambient temperature [F/C] +34 / +1 Nom (max) inlet air temperature

Do not use a cable longer than 10 m. Wire the DC (-) line (blue) as close as possible to the power supply.

Not mounted Sensor Part name Type D Sensor 1 Rotary sector type Cable Part name Type C Cable S For sensor 3m P For power supply 3m Bracket Type Part name E For body end B Bracket M For body middle part S For sensor Electrode needle cartridge Type Part name N Electrode Needle cart. T Tungsten 3. Specifications 3-1.

Leakage voltage Take note that the leakage voltage will increase when a resistor is used in parallel with switching element or a C-R circuit (surge voltage suppressor) is used for protecting a switching device because of the passing leakage voltage through the C-R circuit. The suppressor residual leakage voltage should be as follows.

Under certain circumstances, the use of an electronic type pressure gauge is recommended. 22 0 0 43.5 58 72.5 87 101.5 Supply pressure (psig) 142 Return to Menu Specialty Regulators NARM Series Regulator for Manifold NARM1000, 2000 Dimensions Dimensions Symbol A B C D E F G H J K M P Q R Model NARM1000 .18 .98 1.34 .83 .71 2.20 .63 .35 .71 .75 2.05 .35 .45 .19 (4.5) (25) (34) (21) (18) (

CM PE FM1 PRS P FM2 PE CM FM 12 OLR PTC PTC ILS PRS TB PE GFCI EDV 6 3 6 6 4 2 6 4 7 A A 7 1 7 2 A m 3/h(ANR) 1) (50/60Hz) 0.32/0.375 10 1ANR 65% 2 7 3 7 1 8 C 8 C 8-1 8-2 1) 2) 8-3 8 1 9 G G 9-1 9 1 10 H 10 H 10-1 ( ) 10-2 () AD48-2-A 10 IDFA6E-20-H N.O. () 0.151.0MPa 10 1 10 H IDF-S1941 () 1 AD48-2-A 1 1) 2019 3 2019 2 SERIAL No.XP IDF-S1940

3 Ejector assembly ZK2 EJ A W 10 Nozzle nominal size 07 0.7 10 1.0 12 1.2 15 1.5 Bellows type with groove Flat type with groove 257 ZHP Series Dimensions 30 N 70 Silencer In the case of Flat type P 16.6 EXH. 24.7 P F E D C A PD port 3 6.2 K M Female thread mounting M Male thread mounting Unlocked: 32.2 PD port 2 Locked Unlocked J PD port 1 G H P port L E F 6.2 10 7.8 6.2 Lock screw 14.4 1.4

C C C D D D D Body (material: A6063) K C C C C E E E E E E E E KF flange F F F Fn n n n (KF) () Heater (option) Auto switch H H H H J J J J G G G G B B B B A A A A A A A A Model A B C D E Fn G H J K XLC-25 50 120 48 1 12 40 26 39 27.5 8 XLC-40 65 171 66 2 11 55 41 63 36 9 8 XL-OMO0001-A 5 Guaranteed period and range The warranty period is 2 million cycles (under SMC endurance test conditions

Specified grease pack part number: GR-S-010(10g) When the O-ring for single acting normal open type or end boss type cap is replaced, it is necessary to remove the Type C retaining ring. 16 - 32, 40 1. Remove the retaining ring using the special tool and remove the cap. 2. Loosen the guide bolts and remove the guide. 3.

20 2.5 0.95 25 3 2.25 0.2mm 0.2mm 14 - 3-4. 1025 (1)Assy (2) (3) (4) (5)Assy O Assy :GR-S-010(10g) O C 15 - 32,40 1C 2 3 4.Assy :GR-S-010(10g) C 32 3 40 4 32 2 40 2.5 Assy 16 - 3-5./ 1025 / / / / 1 12 13 2 10,16; 20;25; 14 20,25; 3 15 C 4 5 16 A 6 17 A 18 NO 7 19 NC 8 20 NBR 9 21 NBR 10 22 NBR 11 MHZ2-10 MHZ2-16 MHZ2-20 MHZ2-25 MHZ2-D MHZ2-C MHZ10-PS MHZ16-PS MHZ20

Then, insert the cleaning arm by pressing the part C of the cleaning arm and the part F of the automatic cleaning unit. If the cleaning arm is inserted forcibly while the arrow part is not fit into D-shaped part, it may break.

300mm (lead wire length) I With indicator light/ surge voltage suppressor G G Manual override (locking lever type) Pressure gauge mounting bore 1/8 Port size Indicator light ON OFF OFF ON B B H H N P A P A 37 37 Q Q C C Pressure gauge mounting bore 1/8 4-R R 4-R 36.8 E 36.8 E R P P D D + + MADE IN JAPAN MADE IN JAPAN Model Port size A B C D E G H I K L M N P Q R AV2000-02-G AV2000-02-GS AV2000

glycol aqueous solution, Deionized water Set temperature range Note 1) C 5 to 40 Cooling capacity Note 3), 9) kW 9.5 Heating capacity Note 4) kW 2.5 Temperature stability Note 5) C 0.1 Circulating uid system Rated ow (Outlet) L/min 45 (0.5 MPa) Maximum ow rate L/min 60 Maximum pump head m 50 Settable pressure range Note 6) MPa 0.1 to 0.5 Minimum operating ow rate Note 7) L/min 20 Tank capacity

Plug Connector How to Use L/M Plug Connector How to Order 2. Crimping connection of lead wire and socket Caution L/M Plug Connector For JSY1000 Strip 3.2 to 3.7 mm at the end of lead wires, insert the end of the core wires evenly into the sockets, and then crimp it by a crimping tool.

Dimensions/40 to 100 Basic/CA2YB 4-J 2-P (Rc, NPT, G) MM Width across flats KA G G D E H1 AL B1 K A N F N B C M S + Stroke H ZZ + Stroke (mm) Bore size (mm) 40 50 63 80 100 Stroke range Up to 500 Up to 600 Up to 600 Up to 700 Up to 700 B C A AL B1 D E F G H H1 J K KA M MM N P S ZZ 30 35 35 40 40 27 32 32 37 37 60 70 85 102 116 22 27 27 32 41 44 52 64 78 92 16 20 20 25 30 32 40 40 52 52 10

Lateral 0.2 0.1 200 300 500 100 Load point distance mm LJ1H20 LJ1H30 20 10 Lateral load 100% 10 5000 Lateral load 50% 5000 2000 Horizontal load 100% 2000 Horizontal load 50% 1000 Horizontal load 100% 1000 Horizontal load 50% 500 500 Amount of deflection m Amount of deflection m 200 200 100 100 50 50 20 20 10 Lateral load 100% 10 5 Lateral load 50% 5 Horizontal empty weight deflection 2 2