When a surge generating load such as a relay or solenoid is directly driven, use a type of switch with a built-in surge absorbing element. 4. Since the type of applicable fluid varies depending on the product, be sure to verify the specifications. The switches do not have an explosion proof rating. To prevent a possible fire hazard, do not use with flammable gases or fluids. 5.
Never mount a switch in a place that will be used as a scaffold during piping work. Damage may occur if subjected to an excessive load. Especially when the switch supports piping, do not apply a load of 15Nm or more to the metal part of the switch. 11. Provide a section of straight pipe of at least 8 times the pipe diameter in the piping before and after a switch.
Blanking block assembly (VCA30, 40) VVCA 3 0 2A 00 3 4 Series VCA30 Series VCA40 This is used when a blanking block is mounted on a manifold as preparation for a planned valve installation.
Block off the heat with a cover, etc. 5. Do not use in locations where static electric charges will be a problem. Consult SMC regarding use in this kind of environment. 6. Do not use in locations where spatter occurs. There is a danger of spatter causing a fire.
Block off the heat with a cover, etc. 5. Do not use in locations where static electric charges will be a problem. Consult SMC regarding use in this kind of environment. 6. Do not use in locations where spatter occurs. There is a danger of spatter causing a fire.
A A B (mm) D-A9V D-A9 D-M9 D-M9W D-M9V D-M9WV A B A B Bore size (mm) W Hs A B W A B Hs 32 40 50 63 12 [17] 9 1 12 [17] 9 29 8 [13] 5 3 (0.5) 8 [13] 5 27 16 11.5 1.5 16 11.5 32.5 12 7.5 5.5 (3) 12 7.5 30.5 14 <19> 14.5 4.5 14 <19> 14.5 42 10 <15> 10.5 8.5 (6) 10 <15> 10.5 36.5 16.5 17.5 7.5 16.5 17.5 42 12.5 13.5 11.5 (9) 12.5 13.5 40 [ ]: Values for 5 mm stroke with 32 < >: Values for 10
Use caution, as there is a danger of being burned if a valve is touched directly. 2. Valves may reach high temperatures when continuously energized. Use caution, as there is a danger of being burned if a valve is touched directly. SOL. AC AC SOL. Without light AC SOL.
Block off the heat with a cover, etc. 5. Do not use in locations where static electric charges will be a problem. Consult SMC regarding use in this kind of environment. 6. Do not use in locations where spatter occurs. There is a danger of spatter causing a fire.
Leakage voltage Particularly when using a resistor in parallel with a switching element and using a C-R element (surge voltage suppressor) to protect the switching element, take note that leakage current will flow through the resistor and C-R element, etc., creating a danger that the valve may not shut OFF.
Normally open Normally closed Polycarbonate AD52 -A AD51 -A Nylon AD52 -6-A AD51 -6-A Metal AD52 -2-A AD51 -2-A 1 Enter the piping thread type to of the bowl assembly part number. Nil: Rc thread, N: NPT thread, F: G thread Please consult with SMC separately for psi and F unit display spccifications.
Caution indicates a hazard with a low level of risk which, if not avoided, could result in minor or moderate injury. Caution: Warning indicates a hazard with a medium level of risk which, if not avoided, could result in death or serious injury. Warning: Danger : Danger indicates a hazard with a high level of risk which, if not avoided, will result in death or serious injury.
Bracket mount Panel mount Barb fitting 4/2.5 One-touch fitting 2 Bracket Panel mount example Lead wire length In case of 8 stations 1(P) 3(R) 2(A) 2(A) Connector cable Length: 300 mm 600 mm 1000 mm No.7 No.8 2(A) 2(A) No.5 No.6 2(A) 2(A) No.3 No.4 2(A) 2(A) No.1 No.2 Reduced environmental impact substance RoHS compliant Features 1 Unit Manifold Valve Compact Direct Operated 3 Port Solenoid
Install a suitable filter (strainer) immediately upstream from the valve. As a general rule, use 80 to 100 mesh. Caution 1.
Temperature Data A or B = Series IDUS: Data A Series IDFS: Data B Air pressure Data C = 2 Calculate corrected air flow by using A or B and C. Corrected air flow = (Air flow) (Data A x Data C) Corrected air flow = (Air flow) (Data B x Data C) 3 Select a model having an air flow capacity that is higher than the corrected air flow.
lubricant that has a shielding effect from ozone.
IP8000-011-AG) Note 3) A is applied to approx 90cm3-capacity actuator. B is applied to approx 180cm3-capacity actuator. Note 4) Standard lever is not attached. Note 5) It is to be used together with A or B when tending to overshoot by the use of A or B. It is mounted to the body as a replacement of the standard compensation spring. Note 6) With terminal box, Non-explosion proof.
Using a regulator on the secondary side When mounting a regulator on the secondary side (A port side), use a residual pressure relief regulator (AR2550 to 4050) or a check type regulator (AR2560 to 6060). With a standard regulator (AR1000 to 6000), the secondary side pressure may not be released when this valve is exhausted. 5.
Leakage voltage Particularly when using a resistor in parallel with a switching element and using a C-R element (surge voltage suppressor) to protect the switching element, take note that leakage current will flow through the resistor and C-R element, etc., creating a danger that the valve may not shut OFF.
A counter clockwise until it stops (approx. 45). 4) Install a new element on cover A and insert it into the case.