water 35oC 800 600 400 200 0 0 10 20 30 40 50 60 70 Recirculating fluid temp. oC Fig.9-11 Cooling capacity (HED007) 2) Heating capacity 3200 2800 2400 Heating capacity W Facility water 35oC 2000 1600 Facility water 10oC 1200 Facility water 25oC 800 400 0 0 10 20 30 40 50 60 70 Recirculating fluid temp. oC Fig.9-12 Heating capacity (HED007) 9.5 Performance Chart 9-16 A_HEC-OM-K001-1.7 Chapter
: 4-48 32 : 1-12 65 : M5 x 0.8 93 : M30 x 3.5 05 : 5-40 33 : 1 1/8-7 66 : M6 x 0.75 94 : M36 x 4.0 06 : 5-44 34 : 1 1/8-12 67 : M6 x 1.0 95 : M16 x 1.25 07 : 6-32 35 : 1 1/4-7 68 : M8 x 1.0 96 : M36 x 1.5 08 : 6-40 36 : 1 1/4-12 69 : M8 x 1.25 97 : M36 x 2.0 09 : 8-32 37 : 1 3/8-6 70 : M10 x 1.25 10 : 8-36 38 : 1 3/8-12 71 : M10 x 1.5 11 : 10-24 39 : 1-14 72 : M12 x 1.5 12 : 10-32 40 : 1
PBT Material 30 40 0.5 g Weight 30 6.5 (R) 2 4.5 1 16 4 11 745 ARM10F Series Made to Order Specifications: Please contact SMC for detailed dimensions, specifications and lead times.
Mixed Mounting of VK300 and Manifold Base of Series VK3000 Type VV5K3-20 Type VV5K3-40 1. In the case of VV5K3-20/40 When installing the 3 port valve on the manifold base, plug the R port at the corresponding mark side with the rubber plug (VK3000-8-1) as shown in the figures on the right. Plug Plug 2.
Mixed Mounting of VK300 and Manifold Base of VK3000 Series Type VV5K3-20 Type VV5K3-40 1. In the case of VV5K3-20/40 When installing the 3 port valve on the manifold base, plug the R port at the corresponding mark side with the rubber plug (VK3000-8-1) as shown in the figures on the right. Plug Plug 2. Other manifold 3 port valve can be mounted without any work.
: 4-48 32 : 1-12 65 : M5 x 0.8 93 : M30 x 3.5 05 : 5-40 33 : 1 1/8-7 66 : M6 x 0.75 94 : M36 x 4.0 06 : 5-44 34 : 1 1/8-12 67 : M6 x 1.0 95 : M16 x 1.25 07 : 6-32 35 : 1 1/4-7 68 : M8 x 1.0 96 : M36 x 1.5 08 : 6-40 36 : 1 1/4-12 69 : M8 x 1.25 97 : M36 x 2.0 09 : 8-32 37 : 1 3/8-6 70 : M10 x 1.25 10 : 8-36 38 : 1 3/8-12 71 : M10 x 1.5 11 : 10-24 39 : 1-14 72 : M12 x 1.5 12 : 10-32 40 : 1
HRX-OM-Y120-D Operation Manual Communication function Thermo-chiller Air-Cooled refrigerated type Water-Cooled refrigerated type HRL100-A-20/40 HRL100-W-40 HRL200-A-20/40 HRL200-W-40 HRL300-A-20/40 HRL400-A-40 Keep this manual available whenever necessary 2023 SMC CORPORATION All Rights Reserved To Users, Thank you for purchasing SMCs Thermo chiller (hereinafter referred to as the product
Valve model VCL2 VCW20-12-01A 1/8, 1/4 34 40 25 30 12.8 12.8 5 4.5 6 13 VCW30-12-02A 1/4, 3/8 42 52 30 40 19 19 6 5.5 7 19 VCL3 VCW30-12-04A Note 1) 1/2 48 56 36 44 23 23 6 5.5 7 23 VCW40-12-02A 1/4, 3/8 42 52 30 40 23 23 6 5.5 7 19 VCL4 VCW30-12-04A Note 1) 1/2 48 56 36 44 23 23 6 5.5 7 23 VCW40-12-06A 3/4 56 65 44 53 28.2 28.2 6 5.5 7 26 2 Mounting screws (for mounting bracket) are included
Valve model Port size VCS21 VCW20-12-01A 1/8, 1/4 34 40 25 30 12.8 12.8 5 4.5 6 13 VCW30-12-02A 1/4, 3/8 42 52 30 40 19 19 6 5.5 7 19 VCS31 VCW30-12-04A Note 1) 1/2 48 56 36 44 23 23 6 5.5 7 23 VCW40-12-02A 1/4, 3/8 42 52 30 40 23 23 6 5.5 7 19 VCW30-12-04A Note 1) 1/2 VCS41 48 56 36 44 23 23 6 5.5 7 23 VCW40-12-06A 3/4 56 65 44 53 28.2 28.2 6 5.5 7 26 2 mounting screws (for mounting bracket
Valve model VCW2 VCW20-12-01A 1/8, 1/4 34 40 25 30 12.8 12.8 5 4.5 6 13 VCW30-12-02A 1/4, 3/8 42 52 30 40 19 19 6 5.5 7 19 VCW3 VCW30-12-04A Note 1) 1/2 48 56 36 44 23 23 6 5.5 7 23 VCW40-12-02A 1/4, 3/8 42 52 30 40 23 23 6 5.5 7 19 VCW4 VCW30-12-04A Note 1) 1/2 48 56 36 44 23 23 6 5.5 7 23 VCW40-12-06A 3/4 56 65 44 53 28.2 28.2 6 5.5 7 26 2 mounting screws (for mounting bracket) are included
S0700 S0700 S0700 Body Ported Base Mounted Blanking plate assembly SS0700-10A-2/SS0700-10A-5 It is used by attaching on the manifold block for being prepared for removing a valve for maintenance reasons or planning to mount a spare valve etc. 40.5 40 2 B 4 A Applicable manifold Part no.
Dimensions Foot type: MQMLL 6 25 14 33 42 18.5 2.3 6 9 2-5.5 66 + Stroke 75 + Stroke 93.5 + Stroke 10, 16, 20, 25 LY LH X X Y Y LX LZ Z 4-LC S + Stroke LS + Stroke ZZ + Stroke LT (mm) Bore size (mm) LS LC LT LH LX LY S Z LZ ZZ Y X 10 5.5 83 2.3 14 33 25 65 19 42 108 9 6 16 5.5 92 2.3 18 42 30 74 21 54 119 9 6 20 6.8 137.5 3.2 25 40 40 97.5 20.5 55 166 20 8 25 6.8 142.5 3.2 28 40 47 102.5
(No.4-40 UNC) 4 Lock screw 5 Joint bracket Links units to one another. Transmits signals to the neighboring unit and supplies power. Connector for unit (Plug) 6 y t y t EX600-DXlB EX600-DYlB EX600-DXlCl q w q w e q w er e y t y t y t EX600-DXlD EX600-DXlE EX600-DYlE EX600-DMlE EX600-DXlF EX600-DYlF EX600-DMlF Analog Unit q w e q w e No.
For double solenoid For 3 position type: For 4 position type SX100-40-4DNegative common specifications Electric circuit diagram (With positive common and light/surge voltage suppressor) For single solenoid: SX100-41-4SFor double solenoid For 3 position type: For 4 position type SX100-41-4D[SOL.b] () Coil How to Order
Recommended cables are specified in the accessories section, on page 40. -39No.EX-OMP0013-E Accessories Fieldbus interface connector (1) Cable with communication connector (SPEEDCON) Part number: PCA-1446566 Item Specifications Pin No.
Valve model Port size VCL2 VCW20-12-01 1/8, 1/4 34 40 25 30 12.8 12.8 5 4.5 6 13 VCW30-12-02 1/4, 3/8 42 52 30 40 19 19 6 5.5 7 19 VCL3 VCW30-12-04 1/2 48 56 36 44 23 23 6 5.5 7 23 VCW40-12-02 1/4, 3/8 42 52 30 40 23 23 6 5.5 7 19 VCW30-12-04 VCL4 1/2 48 56 36 44 23 23 6 5.5 7 23 VCW40-12-06 3/4 56 65 44 53 28.2 28.2 6 5.5 7 26 Bracket material: Stainless steel 3 Series VCL Direct Operated
Valve model Port size VCW2 VCW20-12-01A 1/8, 1/4 34 40 25 30 12.8 12.8 5 4.5 6 13 VCW30-12-02A 1/4, 3/8 42 52 30 40 19 19 6 5.5 7 19 VCW3 VCW30-12-04A 1/2 48 56 36 44 23 23 6 5.5 7 23 VCW40-12-02A 1/4, 3/8 42 52 30 40 23 23 6 5.5 7 19 VCW4 VCW30-12-04A 1/2 48 56 36 44 23 23 6 5.5 7 23 VCW40-12-06A 3/4 56 65 44 53 28.2 28.2 6 5.5 7 26 Bracket material: Stainless steel 4.5-5 Series VCW Dimensions
Bore size (mm) D-A3/A4/K3/G3 D-A5/A6/F5/J5 D-Z/Y D-P5DWL 32 BMB2-032 40 BMB2-040 63 BMB1-063 50 BMB1-050 80 BMB1-080 100 BMB1-100 BT-03 BMB4-032 BMB3T-040 BT-05 BMB4-050 BMB3T-050 BT-06 BMB4-063 BMB3T-080 6-12-2 Series C95 Specifications Bore size (mm) 32 40 63 100 50 80 Action Double acting Fluid Air 1.5 MPa Proof pressure 1.0 MPa Max. operating pressure 0.05 MPa Min. operating pressure
Mounting bracket Minimum order quantity Bore size [mm] Contents 20 25 32 40 Mounting nut (M5, Rc1/8, NPT1/8) 1 1 JSN-020B JSN-032B JSN-040B 1 mounting nut Rod end nut 1 NT-02 NT-03 NT-04 1 rod end nut Refer to page 10 for dimensions. 1 Can be used for M and MZ only.
Outlet Air Temperature 50C 70C 100C Inlet air temperature (C) Correction factor Air flow (l/min (ANR)) Model 35.5 42.5 47.5 36 42.5 44 38.5 42.5 45 39 43 45 35 40 44 35.5 40 42 37 40 41.5 38 40 42 34.5 38 40 33 36.5 38 34 36 37 34 35 36 500 1000 1500 1000 2200 3000 2000 3300 4000 4000 5700 7000 HAA7 Air inlet Air outlet Air cooled style after cooler HAA15 HAA22 Auto-drain HAA37 Min.