Do nol loosen the recessed head screw on the top of the sensitivity adiusting screw because ii is lor prelenting the screw trom slipping otf. @ World Wide QS\E Support... North American Branch Offices For a branch office near you call: 1-800-SMC-SMC1 (762-7621) SMC Pneumatics lnc. (Milwaukee) SMC Pneumatics lnc. (Richmond) SMC Pneumatics Inc.
Tightening Torque for Stroke Adjustment Unit Holding Bolts Unit: Nm Bore size (mm) 25 32 40 Tightening torque End lock 1.8 3.5 Operating direction 5.8 L R Caution R L R L R L R L Do not operate with the stroke adjustment unit fixed in an intermediate position.
Do not move the cover upward inadvertently during end plate installation.
Do not block the bleed hole. If the bleed hole is blocked, the product will not operate properly. VBA VBAT AP100 875
Please do not apply force to the coil and frame when installing the piping and valves. If they receive 10 N or more of force, a malfunction may occur. 3. Do not pull the lead wire with excessive force. Applying 10 N or more of load may result in broken wire or contact failure. Manual Override Caution 1.
During transport and installation, do not apply shock to the product, such as by dropping doing so will affect its precision. 2. Regarding the installation posture, place it perpendicular to the ground, with the zero point on the reading of a pressure gauge facing down. 3.
Do not use in locations having an explosive atmosphere. 2. Do not operate in locations where vibration or impact occurs. 3. In locations near heat sources, block off radiated heat. 1. Operate within the range of the maximum operating pressure. VC VDW Caution VQ 1. After a long period of non-use, perform inspections before beginning operation. 2.
Do not use tools on the pressure regulator knob as this may cause damage. It must be operated manually. Air Supply Caution 1. Install an air filter (the AF series) as a preliminary filter on the inlet side of the mist separator regulator to prevent premature clogging. 2.
Do not use tools on the pressure regulator knob as this may cause damage. It must be operated manually. Air Supply Caution 1. Install an air filter (the AF series) as a preliminary filter on the inlet side of the mist separator regulator to prevent premature clogging. 2.
Do not hurt the body seat during installation. Compression of the O-ring of the mating side of the body shall be 0.7 to 0.9mm.
If the product is bent to less than the minimum bending radius, the moisture control tube will be Do not use the product in conditions of compressed air or an environment containing solvents. Recommended equipment coupling after inserting the sleeve again before the fitting is installed when if it slips off. not come out.
Troubleshooting Do not operate the product outside of the specifications. Do not use for flammable or harmful fluids. Fire, malfunction, or damage to the product can result. Verify the specifications before use. Manifolds SJ2000/3000, S0700 series : Refer to the catalogues and operation manuals for details on the solenoid valves and manifolds. How to mount the manifold 1.
No.6 No.5 No.8 No.7 No.10 No.9 Red flashing Wrong switch setting, Parameter writing error Green On Bus-off state, Duplicate MAC ID 16 32 4 8 1 2 Red flashing Off Green On I/O Connection is in the Timed-Out state Do not operate the product outside of the specifications. Do not use for flammable or harmful fluids. Fire, malfunction, or damage to the product can result.
Bit: 7 0 Do not operate the product outside of the specifications. Do not use for flammable or harmful fluids. Fire, malfunction, or damage to the product can result. Verify the specifications before use. Bit No. 6 4 6 4 2 0 0 0 Solenoid on side A 0 2 4 6 8 16 28 30 Output No.
Do not connect multiple NFC readers / writers to a PC. Connection details using the I/O Configurator for NFC and wireless unit To use a wireless system, it is necessary to "pair" a Wireless Base and Remote. Configure this using the I/O Configurator (NFC version).
Non-locking push type Unrestricted 150/50 m/s2 Make sure that dust and/or other foreign materials do not enter the valve from the unused port (e.g. exhaust port).
Do nol loosen the recessed head screw on the top of the sensitivity adiusting screw because ii is lor prelenting the screw trom slipping otf. @
DO Without air cushion (mm) B Bore size (mm) No.
If operating pressure is over the range then cylinder will be damaged and injury by broken pieces. (4) Do not put your hand into the slit of the body without confirming safety. Injury and Bodily harm will occur with the valve operated when valve is operated valve. (5) Do not remove the Cover Fig.1 29 on the actuating part.
Do not apply pressure to this hole. Attach tubing to the vent hole and place the end of the tubing so it is not exposed to dust or water. For the rod end male thread, refer to page 247.