Press the button again to confirm the values of the first 6 digits and move on to input of the next 6 digits. After the input of the next 6 digits is complete, press the button for 1 second or longer to confirm. : As the unit for setting of the first 6 digits, [x 106] and [L] will be displayed. When the button is pressed for 1 second or longer, [0] will start flashing.
Rc1 Flow direction Barrel nipple 25A Y-strainer (Accessory) Y-strainer (40 mesh) 25A Barrel nipple (25A) (Accessory) 141 HRSH090 Series Inverter Type Recommended External Piping Flow External piping circuit is recommended as shown below. 6 Thermo-chiller 1 Facility water outlet (Water-cooled refrigeration) 6 1 Facility water equipment Facility water inlet (Water-cooled refrigeration) 1 7
L 100mm, or stroke 1 2 1 7 5 4 6 2 6 5 7 3 L L 8 Fig 6. Position for application of grease Table 7. Amount of grease units: g Stroke 40 50 63 80 100 P o s i t i o n f o r Bore g r e a s e At 100st 3 to 4 3 to 5 4 to 5 6 to 8 8 to 10 50st added 1 1 1.5 2 3 16 3-2-4. Mounting of seals 1) Rod seal, Cushion seal (Fig 6, ) Pay attention to the mounting direction of the seal.
If a lubricant is used in the system after the replacement of the valve, use turbine oil Class 1 (with no (6) additive) ISO VG32.
Legs (with bolt, nut, flat washer) Element 4 Polyester FGF-OP01 (Set) FGF5-60 5 FGF1 6 Carbon steel 1 5 Hinge bolt Carbon steel Eyenut 6 Carbon steel FGFS1 NBR FGF-KT01 1 O-ring 7 Washer 7 Carbon steel FGFL1 FKM FGF-KT02 1 8 Parallel pin Carbon steel FGF-KT03 (Set) Polypropylene/ NBR FGFS1 1 9 Lifter Carbon steel Holder (with O-ring) 8 Handle 10 Carbon steel FGF-KT04 (Set) Polypropylene
IN MaterialO Model Body Seal Brass, Stainless steel NBR, FPM, EPR Orifice size (mm) Model Port size Rc(PT) VXA212 , 1 8 1 4 , 1 8 1 4 , 1 4 3 8 , 1 4 3 8 , 1 4 3 8 , 1 4 , 3 8 1 2 0 2 3 4.5 VXA213 0 2 VXA223 0 2 4.5 6 8 VXA224 0 2 VXA225 0 2 10 VXA226 0 2 4.1-57 VXA21/22 Normally Closed (N.C.)/Normally Open (N.O.)
Note 1) Tighten within the tightening torque of 0.5 Nm +/-15%. Note 2) Cable (7) external: 6 to 8 mm (1) (2) (6) (5) (4) (3) (7) (8) (11) (9) (10) Figure-1 9 VG300-OMH0002-B TROUBLE SHOOTING Should any trouble be found during operation, trace the source of the trouble in the following or der and take correcitve action.
Perform wiring referring to the wiring diagram below. 38 - NPN type PNP type Input power Input power supply supply IO connecter IO connecter 24VDC 24VDC IN0 1 IN0 1 IN1 2 IN1 2 RESET 3 RESET 3 (Unused) Not connected. 4 (Unused) Not connected. 4 Load Load OUT0 5 OUT0 5 Load Load OUT1 6 OUT1 6 Load Load OUT2 7 OUT2 7 Load Load ALARM 8 ALARM 8 Caution The parallel input/output of this electric
VAC ERR ERR ERR ERR Note) Stations are counted starting from the D side. 50 56 D side U side 1 2 . stations 50 9 3 (8) 6.5 6.5 Dimensions in inch are noted in parentheses. 1 1 82 89.5 SUP, VAC z port 3 3 (6, 1/4") 40 40 EXH, ATM c port 25 25 (6, 1/4") 2 2 2 5 5 OUT x port (4, 5/32") Breathing hole Note) 3.7 (M3 x 0.5) Note) For dimensions of the cable connector, refer to single unit on page
1 ft 3/pulse 0.1 ft -0.918.6 cfm -1.837.1 cfm -3.674.2 cfm (-0.20.2 [ 0]) (-0.40.4 [ 0]) (-0.80.8 [ 0]) 3 0999,999,999 ft 0.1 cfm 3 1 ft -28No.PF-OMS0001CN-A [F 1] OUT1 OUT1 ( )OUT2 H_1(H_2) H_1(H_2) H1(H2) H1(H2) H1(H2) H1(H2) 0 ON 0 OFF () 0 ON 0 OFF () -29No.PF-OMS0001CN-A ( )OUT2 3 3 3 3 6 6 6 6 zhi chi ON OFF ON OFF OU2 -30No.PF-OMS0001CN-A <>OUT1 [F 1
6 e !5 o y i q t u !0 !1 e w r !3 !8 !7 @3 @0 !9 @4 @1 @2 @6 @5 @7 @8 LVM No.
(mm) TIL19 3/4" 3/4" x 5/8" 19.05 TIL25 1" 1" x 7/8" 25.4 TL0403 4 x 3 4 TL0604 6 x 4 6 TL0806 8 x 6 8 TL1008 10 x 8 10 TL1210 12 x 10 12 TL1916 19 x 16 19 TIL01 1/8" TILB01 1/8" 1/8" x 1/16" 3.18 TIL05 3/16" 3/16" x 1/8" 4.75 TIL07 1/4" 1/4" x 5/32" 6.35 TIL11 3/8" 3/8" x 1/4" 9.53 TIL13 1/2" 1/2" x 3/8" 12.7 1/8" x 0.086" Basic diameter 3.18 +0.2 0.1 +0.2 0.1 1.6 0.15 1 0.1 Tolerance
For detailed specifications, refer to page 7-9-1.
2.5 0.5 1 1.5 4.5 4 7.5 9.5 9 11.5 5.5 6 10 11 12 16 14.5 15 11.5 9.5 10 7.5 0 0 3.5 5.5 5 7.5 3.5 3 6.5 8.5 8 10.5 1.5 2 6 7 8 12 1.5(4) 4.5 5 9 10 11 15 2(4.5) Bore size (mm) 1.5(1) 3.5(1) 3(0.5) 5.5(3) Long stroke 12 16 20 25 32 40 1 0.5 6 8 10.5 16.5 11 10.5 16 18 20.5 26.5 9 9.5 13 14 12.5 16 5 5.5 9 10 8.5 12 7 6 11.5 13.5 16.5 22.5 5(2.5) 8 8.5 12 13 11.5 15 10 9.5 15 17 19.5 25.5
Modify the detecting position while the auto switch is secured at the position of (3) in the figure. a Auto switch mounting screw M3 x 0.5 x 8 L (For BQ-1) Auto switch Set screw (Unused) r u t c e y Auto switch mounting bracket d Auto switch mounting screw M2.5 x 0.45 x 6 L b Square nut (For BQ-1) w Cylinder q BQ-1 and BMU1-025 are a set of a and b shown above.
Note 19 - CRJU05~1 11 8 6 12 4 10 3 10 18 11 14 7 9 1 13 15 17 16 2 17 15 14 18 18 Hexagon socket head set screw 2 17 Wear ring 2 16 Magnet 2 15 Piston seal 2 14 O-ring 2 13 Hexagon nut 2 12 Round head no. 0 Philips screw 3 11 Hexagon socket head cap screw 4 10 Bearing 2 9 Hexagon socket head set screw 2 8 Stopper retainer 1 7 Holder 1 6 Stopper 1 5 Cover 2 4 Bearing retainer 1 3 Shaft
Brown Brown Load Load Switch 1 Switch 1 Blue Blue Brown Brown Switch 2 Switch 2 Blue Blue Load voltage at ON = Power supply voltage Residual voltage x 2 pcs. = 24 V 4 V x 2 pcs. = 16 V Load voltage at OFF = Leakage current x 2 pcs. x Load impedance = 1 mA x 2 pcs. x 3 k = 6 V Example: Power supply is 24 VDC Internal voltage drop in switch is 4 V. Example: Load impedance is 3 k.