Moreover, leakage current flow to the load will be n times larger when n auto switches are connected in parallel. 7. Do not use a load that generates surge voltage.
95 100 80 15 CA2 D-M9AL (n 2) 2 80 + 40 (n 4) 2 (n = 4, 8, 12, 16) 85 + 40 (n 4) 2 (n = 4, 8, 12, 16) 95 + 40 (n 4) 2 100 + 40 (n 4) 2 (n = 4, 8, 12, 16) 15 + 40 n (n = 2, 4, 6, 8) (n = 4, 8, 12, 16) CS1 2 (Different surfaces and same surface) 1 65 70 75 10 60 CS2 D-M9AVL (n 2) 2 60 + 30 (n 4) 2 (n = 4, 8, 12, 16) 65 + 30 (n 4) 2 (n = 4, 8, 12, 16) 70 + 30 (n 4) 2 75 + 30 (n 4) 2 (n = 4,
+ 30 (n 4) 2 80 + 30 (n 4) 2 n = 4, 8, 12, 16 10 + 30 (n 2) 2 n = 2, 4, 6, 8 65 + 30 (n 4) 2 n = 4, 8, 12, 16 75 + 30 (n 4) 2 n = 4, 8, 12, 16 n = 4, 8, 12, 16 2 (Different sides and same side) With 1 20 95 100 105 110 D-Y7BAL n 110 + 45 (n 4) 2 105 + 45 (n 4) 2 n = 4, 8, 12, 16 20 + 45 (n 2) 2 n = 2, 4, 6, 8 95 + 45 (n 4) 2 n = 4, 8, 12, 16 100 + 45 (n 4) 2 n = 4, 8, 12, 16 n
Square nut insertion TW NL CY3B CY3R CY1S (mm) Model A 97 102.5 125 EB 21 22 24 H 46 54 63 HA 33.5 42.5 46 HB 33.5 41.5 46 HC 45 53 61.5 HG 17 16 25 HP 42 50 58.5 HT 19 23.5 28 J M5 x 0.8 M5 x 0.8 M6 x 1.0 L 106 108 138 LL 44 48.5 56 LW 71.5 75.5 86 M M5 x 0.8 M5 x 0.8 M6 x 1.0 MM 8 8 10 N 16.5 18 20.5 NL 15 15 18 NT 8 8 9 EA 26.5 26.5 29 CY1L CY1H15 CY1H20 CY1H25 CY1H CY1H Model P M5 x
Slider type (Slide bearing type) Number of auto switches Piping Nil S n 2 pcs. Bilateral piping type 1 pc. n pcs. Nil P2 P1 Auto switch Nil Without auto switch Centralized piping type Plate Refer to the table below for the applicable auto switch model. Note) Auto switch rail and magnet for auto switch included as standard.
"n" pcs. Nil S n Mounting Standard Axial foot type Front flange type Rear flange type Single clevis Double clevis B L F G C D Auto switch Nil Without auto switch (built-in magnet cylinder) Select auto switch, models from the table below. The auto switch is packed together when shipped (unmounted).
3.5 3.5 3.5 6 6 9 9 76 87 87 102.5 26 28 36 42 M5 x 0.8 90 100 104 124.5 126 140 149 177.5 104 114 119 142.5 8 6.5 9 12 M8 x 1.25 depth 13 Rc, NPT, 1/8 M8 x 1.25 depth 13 Rc, NPT, 1/8 M10 x 1.5 depth 15 Rc, NPT, 1/4 9-13-12 12 Series MLU Plate Cylinder with Lock Dimensions Axial foot style LY CL (mm) LH LS LH ZZ LT 114 132 140 166.5 LX 3.2 4.5 4.5 5 LY 11 12 15 18 LZ X 6 8 10 11 Y LD Model
(For AC) (Light/Surge voltage suppressor) (Station 1) (Station n) (Station 1) (Station n) A A A A 13 13 8.7 7.7 (Pitch) n-M3 x 0.5 (A port) 12.6 P = 10.5 n-M5 x 0.8 (A port) 12.6 P = 10.5 (Pitch) M3 M5 L plug connector (L) M plug connector (M) 31.7 (For AC) 30.4 (For DC) 15.6 39.1 (For DC) 45.6 (For AC) 40 (Light/Surge voltage suppressor) (Light/Surge voltage suppressor) 26.4 Other dimensions
M8 X 1.25 10 8 28 25.5 Q R T* V Y N O P Bore (mm) 12 20 5.5 47 7 53.5 22 7 M4 X 0.7 M5 X 0.8 50 15 62.5 36 5 M6 X 1 M5 X 0.8 * Refer to p.4.4-8 regarding the rod end nut which is included. * Dimensions for auto switch model D-F79W. 4.4-10 Stroke Reading Cylinder Series CE1 Foot CE1L Bore size Stroke MK/MK2 RSQ/RSG RSH CE1 Front flange CE2 CE1F Bore size Stroke ML2B ML1C REA REC RHC MTS Rear
No. of auto switches mounted 2 Different sides C85 Auto switch model Same side n Different sides 1 Same side C95 D-C7 D-C80 D-H7 D-H7W D-H7BAL D-H7NF D-C73C D-C80C D-H7C 10 50 15 50 + 45 (n 2) n 2 2 15 + 45 ( ) (n = 2, 4, 6) CP95 10 60 15 60 + 45 (n 2) NCM NCA n 2 2 15 + 50 ( ) (n = 2, 4, 6) 10 65 15 65 + 50 (n 2) Dn 2 2 D-B5/B6 D-G5NTL 15 + 50 ( ) (n = 2, 4, 6) 75 10 15 -X 75 + 55
1 5 Port Air Operated Valve Series SYA3000/5000/7000 How to Order SA One-touch fitting (Inch size) A, B port size Thread type VA Thread piping Nil Rc Symbol Port size Applicable series M5 01 02 Symbol Port size Applicable series N3 N7 N3 N7 N9 N7 N9 G F SA 5 32" SYA3000 SYA5000 SYA7000 One-touch fitting for M5 x 0.8 N NPT SYA3000 1 4" 1 8 1 4 One-touch fitting for NPTF T VA 5 32" One-touch
(a) Direct Mounting with four M5 screws Mounting screw (M5) 4pcs. (prepared by customer) (b) DIN rail mounting The figure on the right shows how to mount the DIN rail mounting brackets. Secure the DIN rail mounting bracket using the mounting screws (M5 x 8) 2 places on one side (4 places on both Mounting screw M5X8 sides).
(a) Direct Mounting with four M5 screws Mounting screw (M5) 4pcs. (prepared by customer) (b) DIN rail mounting The figure on the right shows how to mount the DIN rail mounting brackets. Secure the DIN rail mounting bracket using the mounting screws (M5 x 8) 2 places on one side (4 places on both Mounting screw M5X8 sides).
M5 x 0.8 Body side VZA222-P-M5 M5 x 0.8 0.13 0.35 0.52 0.15 0.43 0.60 N.O. M5 x 0.8 Body side VZA214-1P-01 M5 x 0.8 0.22 0.35 0.85 0.25 0.30 1.0 N.C. Rc 1/8 Sub-plate side VZA214-2P-01 M5 x 0.8 0.22 0.35 0.85 0.25 0.30 1.0 N.C. Rc 1/8 Body side VZA224-1P-01 M5 x 0.8 0.22 0.35 0.85 0.21 0.25 0.90 N.O. Rc 1/8 Sub-plate side VZA224-2P-01 M5 x 0.8 0.22 0.35 0.85 0.21 0.25 0.90 N.O.
1 2 3 4 5 6 7 Stations D-side 8 U-side M12 Female thread 2-C8 3(R) port 0 DIN rail clamp screw 1 62.5 60 (12) 40.5 25 9.5 7.5 18.5 M12 Male thread 20.5 (7.5) 2n-C3, C4, C6, M5 C3: 3.2 One-touch fitting C4: 4 One-touch fitting C6: 6 One-touch fitting M5: M5 thread 2-C8 1(P) port 34 P = 10.5 (mm) Formulas: L1 = 10.5n + 45, L2 = 10.5n + 93.5 n: Stations (maximum 16 stations) n L L1 L2 L3 L4
VP300-224-1 (M3 x 36) VP500-224-1 (M4 x 46) VP700-224-1 (M5 x 66) Thread type Series For valve mounting 3 5 7 VPA344 VPA544 VPA744 Nil F N T Rc G NPT NPTF Caution Tightening Torque of Mounting Screw Port size Symbol 1 2 VPA344 1/8 1/4 VPA544 1/4 3/8 VPA744 3/8 1/2 M3: 0.8 Nm M4: 1.4 Nm M5: 2.9 Nm 31 Series VPA300/500/700 Air Operated Valve Base Mounted/Single Unit Series VPA300/Base Mounted
Contents Bore size (mm) Set of left nos. @7, @8, @9, #0 Set of left nos. @7, @8, @9, #0, #1 @6 @7 @8 @9 #0 #1 Wear ring A Special resin 6, 10: Not available 6 CY1S6-PS-N Wear ring B Special resin 10 CY1S10-PS-N Cylinder tube gasket NBR Guide shaft gasket NBR 15 20 25 32 40 CY1S15-PS-N CY1S20-PS-N CY1S25-PS-N CY1S32-PS-N CY1S40-PS-N Piston seal NBR Set of left nos. @6, @7, @8, @9, #0, #1 Scraper
plug L plug connector (L) M plug connector (M) Sub-plate M5 x 0.8 (P2) Silencer (P2) AN120-M5 (Option: N) (Except VEX3420) Plug (1/8) Refer to Table (1).
Nil S N 2 pcs. 1 pc. n pcs. N Non-locking type C95 Manual release CP95 NCM Applicable Auto Switch/Refer to page 6-16-1 for further information on auto switches.