Akihabara UDX 15F, 4-14-1, Sotokanda, Chiyoda-ku, Tokyo 101-0021, JAPAN Phone: 03-5207-8249 Fax: 03-5298-5362 https://www.smcworld.com 2024 SMC Corporation All Rights Reserved Specifcations are subject to change without prior notice and any obligation on the part of the manufacturer. D-G
53 23 25.5 25.5 35 40 40 12 14 14 41.5 44.5 44.5 ( ): N.O. 17-3-41
Ltd. 1-16-4 Shimbashi, Minato-ku, Tokyo 105 JAPAN Tel: 03-3502-2740 Fax: 03-3508-2480 Specifications are subject to change without prior notice and any obligation on the part of the manufacturer. Printed in Japan. 1st printing April, 1998 D-SMC.L.A. P-67.5 (YG)
Ltd. 1-16-4 Shimbashi, Minato-ku, Tokyo 105-0004, JAPAN Tel: 03-3502-2740 Fax: 03-3508-2480 URL http://www.smcworld.com 2000 SMC CORPORATION All Rights Reserved Specifications are subject to change without prior notice and any obligation on the part of the manufacturer. Printed in Japan. 1st printing August, 2000 D-SMC.L.A. P-80 (JT)
Ltd. 1-16-4 Shimbashi, Minato-ku, Tokyo 105-0004, JAPAN Tel: 03-3502-2740 Fax: 03-3508-2480 URL http://www.smcworld.com 2000 SMC CORPORATION All Rights Reserved Specifications are subject to change without prior notice and any obligation on the part of the manufacturer. Printed in Japan. 1st printing August, 2000 D-SMC.L.A. P-80 (JT)
Ltd. 1-16-4 Shimbashi, Minato-ku, Tokyo 105-0004, JAPAN Tel: 03-3502-2740 Fax: 03-3508-2480 URL http://www.smcworld.com 1999 SMC CORPORATION All Rights Reserved Specifications are subject to change without prior notice and any obligation on the part of the manufacturer. Printed in Japan. 1st printing December, 1999 D-SMC.L.A. P-80 (D)
B H C D d NT-02 NT-03 NT-04 M8 X 1.25 13 5 15.0 12.5 CJP M10 X 1.25 17 6 19.6 16.5 M14 X 1.5 22 8 25.4 21.0 CJ2 Mounting Nut (mm) CM2 Material: Carbon steel C85 Applicable pin part No. Part No.
Filtration rating has to be 5m or smaller. 3(R) Model VHS2500 VHS3500 VHS4500 VHS5500 A 60 78 85 136 B 20 29 32 56 C 12.8 12.8 12.6 32 D 40 53 70 90 E 44 53 64 80 F 33 42 49 65 G 28 29 36 54 H 7.5 7.5 10 10 3.6-18
Rod boot MB W R K F MB1 CP95 Stroke (mm) Refer to standard stroke table on p.1.11-4 C95 Applicable Auto Switches/ Tie rod mounting C92 Load voltage Lead wire (m) Indicator Mounting bracket Applicable load Auto switch model Special function Style Electrical entry Wiring (Output) 0.5 () 3 (L) 5 (Z) AC DC CA1 3 wire (Equiv. to NPN) 5V A56 IC CS1 Yes Reed switch Solid state switch 32,40 BT-03
25 5, 10 Rear Flange L1 Without auto switch A 26 26 32 35.5 With auto switch A 31 31 42 45.5 Bore (mm) Stroke range (mm) FD FT FV FX FZ L Inch Metric 14 15.5 18.5 22.5 B 17 17 19.5 22.5 B 22 22 29.5 32.5 11.5 11.5 12.5 14.5 12 16 20 25 4.5 4.5 6.6 6.6 5.5 5.5 8 8 25 30 39 42 45 45 48 52 55 55 60 64 3.5 3.5 4.5 5 5, 10 Double Clevis Without auto switch With auto switch A 40.5 41.5 51 57.5
End plate ass'y 1 pc. 2500 3000 A B 146 Return to Menu Specialty Regulators NARM Series Regulator for Manifold NARM2500, 3000 P Dimensions Symbol A B C D E F G H I J K L M N O P Model NARM2500 .24 .67 1.73 2.20 1.65 4.98 2.28 1.77 .67 .83 1.50 1.65 1.14 1.89 2.68 1.32 (6) (17) (44) (56) (42) (126.5) (58) (45) (17) (21) (38) (42) (29) (48) (68) (33.5) NARM3000 .28 .83 2.13 2.68 2.17 6.04
VF KQ2P-04 KQ2P-06 KQ2P-08 KQ2P-10 KQ2P-03 KQ2P-07 KQ2P-09 KQ2P-11 4 6 8 10 5/32" 1/4" 5/16" 3/8" 16 18 20.5 22 16 18 20.5 22 32 35 39 43 32 35 39 43 6 8 10 12 6 8.5 10 11.5 VP4 VQ 1/2 VQ 4/5 Port plug VVQ1000-58A VQC 1/2 VQC 1/2 The plug is used to block the cylinder port.
Ltd. 1-16-4 Shimbashi, Minato-ku, Tokyo 105-8659, JAPAN Tel: 03-3502-2740 Fax: 03-3508-2480 URL http://www.smcworld.com 2002 SMC Corporation All Rights Reserved Specifications are subject to change without prior notice and any obligation on the part of the manufacturer.
D d H Part no B C 30 M22 X 1.5 26 8 26 SOR-20 20 15.0 12.5 M8 X 1.25 5 13 NT-02 20 36.9 M24 X 1.5 32 8 32 SOR-25 25 19.6 16.5 M10 X 1.25 6 17 NT-03 25/32 43.9 M30 X 1.5 38 9 38 SOR-32 32 25.4 21.0 M14 X 1.5 8 22 NT-04 40 47.3 M33 X 2.0 41 11 41 SOR-40 40 4.10-6 High Power Cylinder Series RHC How to Rotate the Relief Valve Body The relief adjustment screw can be placed in any direction by
1/8 R port: Rc 1/8 01 Nil None 1 station Port size Nil Rc G NPT NPTF CE-compliant F With bracket (Not mounted) F N T 01 Rc 1 8 20 20 stations Q CE-compliant Nil A port: Rc 1/8 Note) Applicable only for DIN terminal type Type 42: Base mounted (A port side ported) Applicable solenoid valve VK334-(-Q) How to Order VV3K3 05 01 42 Applicable blanking plate assembly VK300-42-1A Thread type
VK300-82-2-01 VK300-82-2-03 110 VAC 110V VK300-82-2-02 200 VAC 200V VK300-82-2-04 220 VAC 220V DIN terminal type VK300-82-2-07 VK300-82-4-51 VK300-82-4-06 VK300-82-3-05 VK300-82-3-53 240 VAC 240V 6 VDC 6V 12 VDC 12V 24 VDC 24VD 48 VDC 48VD Indicator light (Built-in connector) Marking Circuit with indicator light AC circuit diagram 12 VDC or less circuit diagram 24 VDC or more circuit diagram
How to Order Integrated Display Type PF2A7 H M Flow rate range Unit specification High flow rate type 03 06 12 150 to 3000 l/min 300 to 6000 l/min 600 to 12000 l/min Lead wire (Refer to page 35.)
30 to 90 CKZT80-A015B 30 to 90 80 CKZ80-42 3680N-R A B C 30 to 105 CKZ80-42 3680N-R D E F 30 to 105 For mounting bolt, a hexagon socket head cap screw and a spring washer No. 2 are recommended.
Ltd. 1-16-4 Shimbashi, Minato-ku, Tokyo 105-0004 JAPAN Tel: 03-3502-2740 Fax: 03-3508-2480 Specifications are subject to change without prior notice and any obligation on the part of the manufacturer. Printed in Japan. 1st printing June, 1999 D-SMC.L.A. P-77 (YG)
VK300-82-2-01 100 VAC V100 VK300-82-2-03 110V 110 VAC 200 VAC 220 VAC VK300-82-2-02 200V VK300-82-2-04 220V S070 240V 6V 12V 24VD 48VD 240 VAC 6 VDC 12 VDC 24 VDC 48 VDC VK300-82-2-07 VK300-82-4-51 VK300-82-4-06 VK300-82-3-05 VK300-82-3-53 DIN terminal VQD VQD-V Light (Built-in connector) Marking Circuit with light AC Circuit diagram 12 VDC or less Circuit diagram 24 VDC or more Circuit