Body Brass Body Hydrolic Oil Non-Flammable NR NR NR NR Standard R R R R Hydrochloric Acid NR NR NR NR Hydrogen R R R R # Inert Gases R R R R JP4 JET Fuel V V V V JP5 JET Fuel V V V V Kerosene R R R R Ketones PP NR PP NR Lacquer PP PP PP PP Linseed Oil R R R R Lubrication R R R R Mercury R*** NR R*** NR Natural Gas R R R R Nitric Acid PP NR PP NR Nitrogen R R R R Oxalic Acid NR NR NR NR Oxygen
Description IR1000 IR1010 IR1020 IR2000 IR2010 IR2020 / 2120 IR3000 IR3010 IR3020 / 3120 Bracket P36201023 P36202028 P36203018 Pressure gauge G33-2-01 G33-4-01 G43-4-01 G43-4-01 G33-10-01 G43-2-01 G43-10-01 G43-2-01 G43-10-01 Accuracy 3% (full span) 2 Series IR1000/2000/3000 Construction IR1000 IR2000 IR3000 Fixed throttle SUP side passage OUT side passage SUP side passage SUP side passage
(A) 2 1 (P) 3 (R) Rubber seal type VQZ200 300 / Metal seal type 3 2 1 3 2 1 N.C. N.C. (A) 2 (A) 2 3 (R) 1 (P) 3 (R) 1 (P) 3 2 1 3 2 1 N.O. (A) 2 N.O. (A) 2 3 (R) 1 (P) 3 (R) 1 (P) Parts list No.
R P R R P R L (10) 8 End plate side End plate side (24) (35) 5.5 Silencer with One-touch fitting This is a silencer which can be attached to the R (exhaust) port of a manifold using a One-touch fitting. Rail mounting hole pitch 12.5 C 9 8 7 6 5 4 3 2 1 0 No.
Note 2) Assembly includes a bracket and 2 mounting screws. Note 3) Please consult with SMC regarding the set nuts for the 10-/21-AR50(K)-B and AR60(K)-B. Note 4) in part numbers for a round pressure gauge indicates a type of connection thread. No indication is necessary for R; however, indicate N for NPT.
VQ1000-FPG-C4M5-D: 6 sets Double check block 757 S0700 Series Construction Body Ported Construction 2(B) (A)4 S0716 2-Position Single r u e w q 3(R2) (R1)5 1 (P) t y i 2-Position Double S0726 2(B) (A)4 r u e w q 3(R2) (R1)5 1 (P) t y i 3-Position Closed Center S0736 r u e w q 2(B) (A)4 (R1)5 1 (P) 3(R2) t y i 4-Position Dual 3-Port Valve S07A6 r u e w q 2(B) 4(A) 5(R1) 3(R2) 1(P) N.C. + N.C
Caution indicates a hazard with a low level of risk which, if not avoided, could result in minor or moderate injury. Caution: Warning indicates a hazard with a medium level of risk which, if not avoided, could result in death or serious injury. Warning: Danger : Danger indicates a hazard with a high level of risk which, if not avoided, will result in death or serious injury.
X M ISE40A 2 K ISE40A -0.11.000 MPa ZSE40A 0.0-101.3 kPa ZSE40AF -100.0100 kPa 1 01 R1/8 (M5) A A N01 NPT1/8 (M5) W1 Rc1/8 B B WF1 G1/81 D D M5 M5X0.8 () E C4 4 C6 6 F + 1IS0228-1 P10/1 X NPN2() Y PNP2() 1 R NPN2 +/ T PNP2 +/ M SI2 P (psi)1 S NPN2 +/ 1 2kPaMPa V PNP2 +/ -9No.PS-OMM0006CN-E /1 1 01 N01 W1 WF1 M5 C4 C6 A A ZS-24-A X X X B B ZS-24-B X X X X X D D ZS-24-D X X X
M5 01 02 03 04 M5 x 0.8 R R R R 1 8 1 4 3 8 1 2 Symbol Specifications -X12 Lubricant: Vaseline -X21 Grease-free (Seal: Fluorine-coated) + Throttle valve (Without check valve) -X214 Throttle valve (Without check valve) Note) M5 size: S (with seal) is not necessary. 611 A AS Series Construction AS1201-M5 AS2201/3201/4201 AS3201-02 o !1 w r u y e t !5 !2 !4 q !0 !3 i Component Parts No.
If these items need to be supported, provide an additional support. r A Class 2 Pressure Vessel Pressure Resistance Certificate is provided with those below, which are considered to be Class 2 pressure vessels. Make sure to store the certificate in a safe location.
Drain guide 1/4 Note 4) AFM30, 40 Rc NPT G Nil C AFM20 to 40 1/8 1/4 3/8 1/2 3/4 01 02 03 04 06 R Flow direction: Right to left AFM20 to 40 N Note 1) Float type auto drain (N.O.)
Selected for contact output 1 AL.01 Contact output 2 function RMT Contact output 2 operation A Selected for contact output 2.
Selected for contact output 1 AL.01 Contact output 2 function RMT Contact output 2 operation A Selected for contact output 2.
Selected for contact output 1 AL.01 Contact output 2 function RMT Contact output 2 operation A Selected for contact output 2.
Applicable cylinder bore size (mm) AS121-M5 Model Port size 4 6 8 10 12 M5 x 0.8 6, 10, 16, 20 Construction 1 8 AS221-01 R 20, 25, 32 1 4 AS221-02 R 20, 25, 32, 40 3 8 AS321-03 R 40, 50, 63 1 2 AS421-04 R 63, 80, 100 Note) marking is electroless nickel plated, provided as standard.
[Check valve] A check valve is a safety device intended to prevent reverse flow. The AP 64 is a unique design with only one moving part in the gas stream, an O-ring. It is a springless design, free of springs and poppets. [Vacuum generator] A venturi device that creates vacuum by flowing gas through a nozzle.
Grommet: G Conduit: C Approx. 300 Approx. 280 D D Q F Q F C C G (PF) 1/2 R R E E A H 2-P Port size 2-M B B A H 2-P Port size 2-M L L K K DIN connector: D Conduit terminal: T Cable 6.8 to 10 27.5 F F Q (Q) S 34 25 U R C R C (44) G (PF) 1/2 E B A H D 2-P Port size (S) E G (PF) 1/2 B A H D 2-M 2-P Port size 2-M L L K K N.C.
1/4 R 1/4 R 1/4 R 1/4 14 14 14 14 20 20 20 20 14 14 14 14 D 2 A Connection thread H1 L1 Copper extension nozzle: KNL (mm) Model Nozzle size D Outside diameter L1 Outside diameter KNL3-06-150 KNL3-06-200 KNL6-06-150 KNL6-06-200 1.5 2 1.5 2 6 6 6 6 300 300 600 600 D L1 Note) When a copper extension nozzle is ordered separately, a self-align fitting will also be required for connection with