SMC Corporation of America
Elite Part Number Search
Search Results "AFF80D-14-B"

and port. * The figures below indicate the CKU32-lRAL-X2321. 14.50.1 14.50.1 (29) 27 70 D d Q Q 0 0.05 120 K C SR 87.5 45 15.5 14.5 26 (4) MK 8 to 10 Diamond cut shape (Guide pin dia.: 9.5 or more) 30 MK2T 490.1 5 (6.4) CK1 14 14 590.05 CLK2 (188.5) 2 x 6H7 through +0.012 0 CLKG 5.5 59 4 x 6.6 through 18 CKQ CLKQ Clamp arm position CK CLK CK CLK A Same as the port side B Opposite side of

L1=(14 x n)+36 10 16 14 10 14 Y W Pressure gauge (Accessory) V X 2 x 4.3 L3=50+R+V L4=50+T+X H H L L S S O O M4 thread hole U U C C P P K K 50 SMC 25 S T R L2=(14 x n)+29 29 55 (Max. 58) Note) U IN IN IN 33 15 14 Note) Max. dimension is the size when the knob is unlocked.

CD D E V MA Air release Cushion valve NB NA K F A B C W W CX RR L S + Stroke ZZ + Stroke H CB Stroke range Bore size (mm) B CD F A D CB G C E GA J NB S CX GB L NA P PJ RR MM MA K H 40 52 14 64 8 25 to 800 M6 x 1 M16 x 1.5 46 29 12 22 22 19 40 34 33 107 20 16 19 3/8 58 17 19 47 50 25 to 800 65 64 M8 x 1 M20 x 1.5 46.5 28.5 14 15 28 28 24 50 42 34 108 20 16 19 3/8 58 17 25 11 59 +0.043 0 63

MU-D02 MU-D03 MU-D04 MU-D05 +0.058 0 +0.058 0 +0.058 0 +0.058 0 +0.058 0 +0.058 0 +0.058 0 +0.070 0 8 10 10 14 8 10 10 14 Applicable pin no. CD-MU02 CD-MU03 CD-MU04 CD-MU05 DZ 8 10 10 14 CZ 8 10 10 14 DY 9 11 13 16 CX 9 11 13 16 DX 18 22 26 32 CT 9.5 11 14 17 DT 9.5 11 14 17 CR 5.3 6.4 8.4 10.5 DR 5.3 6.4 8.4 10.5 CL 26 42 54 64 DL 26 42 54 64 Part no.

(B contact). Contact output signal 5selects Signal type and N.O. (A contact ) or N.C. (B contact). Contact output signal 6selects Signal type and N.O. (A contact) or N.C. (B contact).

A specified earth leakage breaker is installed for option B [Earth leakage breaker], option B [Earth leakage breaker with handle] of each model.

6 6.5 10.5 13.5 16.5 19.5 B 12.5 15.5 18.5 21.5 A 29 29.5 33 24 28.5 29 B 6.5 7 11 14 17 20 A 26 26.5 30 21 25.5 26 B 3.5 4 8 11 14 17 A 19.5 24 24.5 B 9.5 12.5 15.5 A 31.5 22.5 27 27.5 B 9.5 12.5 15.5 18.5 A 35.5 26.5 31 31.5 B 13.5 16.5 19.5 22.5 MK220 MK225 MK232 MK240 MK250 MK263 Auto Switch Mounting Bracket Part No.

Series CLK1P/CLK1G Auto Switches/Proper Mounting Position and Height for Stroke End Detection D-C7, D-C8 A 8.5 D-H7, D-H7W, D-H7F 8.5 A Hs B Hs B 16 14 14 26 29 (36) D-C73C 8.5 A D-H7C 8.5 A Hs B B Hs 14 36.7 38.2 D-G5NT D-B5, B6 B A Hs Hs B A 24.5 24.5 13 33 13 33 Hs D-A3 D-G3, D-K3 B A 49 B Hs A 49 34 56 18 36 18 36 B D-A4 Hs A 34.5 56 18 36 Minimum Strokes for Auto Switch Mounting Minimum

3.2 3.2 6.5 7 7 14 1 3H9 ( ) depth 3 +0.025 0 A B 4 3H9 ( ) depth 3 +0.025 0 NN x M4 x 0.7 thread depth 8 HA GA A-A B-B (mm) Model F 25 25 26 32 46 50 N 4 4 6 6 6 6 G 7 14 8 8 31 H 25 28 31 29 30 NN 2 2 3 3 4 4 GA 13 14 29 39 37 61 HA 19 28 27 31 58 60 I 11 10 12 14 13 12 J 17 28 40 52 78 105 K 23.5 33.5 43.5 53.5 63.5 88.5 KA 82.5 112.5 NA 4 4 4 4 8 8 M 46 56 70 84 109 135 Z 45.5 55.5

Metal bowl with level gauge Metal bowl Metal bowl Optional specifications B B B B B N.C.: Gray N.O.: Black B B O S O S M5 x 0.8 Width across flats 17 1/4 10 One-touch fitting Barb fitting Applicable tubing: T0604 Standard specification Bracket mounting size Accessory specification With pressure gauge With auto drain Model Port size B C D A K J H G F E Q T N P K L M B AC10B AC20B AC25B AC30B

Option Bracket J: With drain guide (Option) female thread T: With element service indicatior Maintenance space Drain Element service indicator Dimensions with mounting bracket Model Port size (Nominal size B) A B C D E F G H 10 10 10 10 10 10 10 10 10 I 56 66 66 80 80 90 90 100 150 J 15 20 17 22 19 25 21 30 40 K 5 8 8 8 8 10 10 10 15 L 9 12 12 14 14 14 14 16 20 M 5.5 6 6 7 7 9 9 9 11 N 35

Hs A B A B Proper Auto Switch Mounting Position (mm) D-A7H, A80H, A73C, A80C D-F7, F7V, F79F, J79 D-J79C, F7W, F7WV D-J79W, F7BAL, F7BAVL D-A7 D-A80 D-F7NTL D-A79W Bore size (mm) B B A A B A B A 32 3 11 51 43 6 46 5.5 45.5 40 5.5 13.5 49.5 57.5 8.5 52.5 8 52 50 19 11 53.5 61.5 14 56.5 13.5 56 63 22 14 59 67 17 62 16.5 61.5 Auto Switch Mounting Height (mm) D-A7H, A80H D-F7, J79, F7W D-J79W

Description Material Note 1 Body A PBT 2 Body B Brass Electroless nickel plating 3 Knob POM 4 Needle PBT 5 Needle guide Brass Electroless nickel plating 6 U-seal HNBR 7 O-ring NBR 8 O-ring NBR 9 Cassette 10 Seal NBR 11 Bonnet A POM 12 Bonnet B POM 13 Gear POM 14 Indicator gear POM 15 Clip Stainless steel 16 Gasket NBR/Stainless steel q t r u i !6 !

B Contact output signal 3 selected alarm Sets the alarm selected for the contact output signal 3. ---(AL.01)6 1: Default when CO02 is set to PRO1 or PRO2. 4: Default when CO23 is set to A.SEL. 2: Default when CO15 is set to SW-A or SW-B. 5: Default when CO26 is set to A.SEL. 3: Default when CO19 is set to SW-A or SW-B. 6: Default when CO29 is set to A.SEL.

(c) (a) (b) (c) (b) (c) (a) (b) (c) (a) (b) (c) (b) (c) (a) (b) (c) (b) (c) (a) (b) (c) Note 1) The above (a), (b), (c) indicate heater mounting positions.

P Q R S 4 4 20.6 15.6 10.4 6 6 21.6 16.6 12.8 F L AT T Y P E F L AT W I T H R I B Y Model A B C D E F G H I Flat Flat with Rib ZPR20 20 23 14 29 39.8 57.6 68.6 91.5 102.6 4 1.7 ZPR25 25 28 14 29 39.8 57.6 68.6 91.5 102.6 4 1.8 ZPR32 32 35 14.5 29.5 40.3 58.1 69.1 92 103.1 4.5 23 D E E P T Y P E Model A B C D E F G H I Y ZPR25D 25 28 20 35 45.8 63.6 74.6 97.6 108.6 10 A P P L I C A B L E T

SOL. location A B A B A B A B () A B () () 0 1 2 3 4 5 6 Double Double Single SI unit A side B side 3 position A B A B B A B A B A VQC Double Double Single SI unit A side B side 3 position Stations 1 2 3 4 5 SQ The places of asterisk are not used. 3 position uses two stations for wiring.

SOL A SOL B SOL A SOL B CYL CYL EXH IN EXH IN SOLENOID B ENERGIZED SOLENOID A ENERGIZED SOLENOID A DE-ENERGIZED SOLENOID B DE-ENERGIZED NOTE: ALL PORTS OPEN WHEN BOTH SOLENOIDS ENERGIZED ALL PORTS CLOSED WHEN BOTH SOLENOIDS DE-ENERGIZED OPTIONS AVAILABLE: 3 WAY HI-PRESSURE VALVE HOUSING OPTIONS see page 78 COIL OPTIONS see page 79 MISCELLANEOUS OPTIONS see page 76 *STRAIN RELIEF CONNECTOR

P . 14-20-57 14-20-42 2 Odor Removal Filter Series AMF How to Order AMF150 to AMF850 AMF 250 03 R B Option R IN-OUT reversal direction Body size Bracket Accessory (Option) 150 Standard 1 8 250 Standard 1 4 350 Standard 3 8 450 Standard 1 2 550 Standard 3 4 650 850 B 1 4 B 3 8 04 B 1 2 06 B Nil Nil B Piping port (B dimension) 1 Standard 11 2 Standard 01 B 1 8 02 03 Thread type Nil Rc F G N

Insert the holding block (A) (8) into the groove of the cover (A) (9), place the cover (B) (10) on top, and fasten the cross recessed round head screw (11). 4. Insert the auto switches (2) into the switch blocks (A) (12) and (B) (13) and mount them to the holding block (B) (14) using the cross recessed round head screws (16).