pilot port) 44 62 9 9 91 44 62 Station number 50.5 59 2-Rc 1/8 (External pilot port) R4.5 R4.5 50.5 9 9 U side entry (LU) U side D side D side U side n 15 X X n X 12 12 12 12 8 B 2 A 4 B 2 A 4 8 Manual override 7 B 2 A 4 SMC SMC SMC SMC SMC SMC SMC B 2 A 4 7 A B A B A B A B A B A A A B A B A B A B A B A A SMC SMC SMC SMC SMC SMC SMC B B B A A A A A A A B A B 2 A 4 6 B 2 A 4 6 B B A A A A

Optional specification Note 2) With barb fitting B With drain guide B Metal bowl B 85 123 166 166 200 200 276 292 293 Metal bowl with level gauge Model B AC10 AC20 AC25 AC30 AC40 AC40-06 AC50 AC55 AC60 161 161 195 195 272 287 288 160 160 194 194 271 286 287 186 186 220 220 296 312 313 4 F.R.L.

(B contact). Contact output signal 5selects Signal type and N.O. (A contact ) or N.C. (B contact). Contact output signal 6selects Signal type and N.O. (A contact) or N.C. (B contact).

AL40-06 AL50 AL60 25 40 53 70 75 90 95 Optional specifications With drain cock B 85 123 153 187 187 261 279 Metal bowl B 82 121 142 176 176 250 268 Drain cock with barb fitting B 161 195 195 269 287 Model Metal bowl with level gauge Metal bowl with drain cock & level gauge B 162 196 196 270 288 Metal bowl with drain cock B 85 124 166 200 200 274 292 S 38 45 45 S 38 45 45 B

Nil M5 x 0.8 Rc 1/8 Rc 1/8 Rc 1/8 Rc 1/4 TF G 1/8 G 1/8 G 1/8 G 1/4 TN NPT 1/8 NPT 1/8 NPT 1/8 NPT 1/4 CY3B15 CY3B20 CY3B25 CY3B32 CY3B40 b C H B d M10 x 1.0 M20 x 1.5 M26 x 1.5 M32 x 2.0 H 4 8 8 10 B 14 26 32 41 C 16.2 30 37 47.3 Part No.

Stations Scale: 37% Stations [With external pilot] 2n1-M5 x 0.8 (A, B ports) 24 13.3 (Pitch) P=10.5 13.3 24 16.2 16.2 34 17 36.7 34 B 2 B 2 B 2 B 2 B 2 B 2 B 2 B 2 B 2 B 2 PE R 3 R 3 P 1 P 1 X A 4 A 4 A 4 A 4 A 4 A 4 A 4 A 4 A 4 A 4 2-One-touch fitting 2-One-touch fitting 2n2-One-touch fitting (X, PE ports) Applicable tube O.D.: 6 (P, R ports) Applicable tube O.D.: 8 (A, B ports) Applicable

Side support B MY-SB Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 2-J C D A B (mm) A 61 70 87 B 75 84 105 C D E F G H J Part no.

Side support B MY-SB 2-J C D A B (mm) A 61 70 87 B 75 84 105 C D E F G H J Part no.

IC circuit Table 1 Manufacturability Check List by Mounting Type and Port Position Yes 100 V 100 V or less No Yes No Yes IC circuit Mounting bracket B LA CB TA FY FZ Grommet 12 V Relay PLC Port position 2-wire 100 V, 200 V 24 V A64 200 V or less Nil A B C D E A59W Diagnostic output (2-color indicator) Water resistant type auto switches can be mounted on the above models, but in such case

A B A B A B A B A B A B A B A B A B A B 40 10 8 6 4 4 1 5.5 3.5 3.5 0.5 0.5 0 1 0 7 4 2.5 0 4.5 1.5 12 9 50 10 8 6 4 3.5 1.5 5.5 3.5 3 1 0 0 0.5 0 6.5 4.5 2 0 4 2 11.5 9.5 63 12.5 11.5 8.5 7.5 6 5 8 7 5.5 4.5 2.5 1.5 3 2 9 8 4.5 3.5 6.5 5.5 14 13 80 16 14 12 10 9.5 7.5 11.5 9.5 9 7 6 4 6.5 4.5 12.5 10.5 8 6 10 8 17.5 15.5 100 17.5 16.5 13.5 12.5 11 10 13 12 10.5 9.5 7.5 6.5 8 7 14 13 9.5

Nil M5 x 0.8 Rc 1/8 Rc 1/8 Rc 1/8 Rc 1/4 TF G 1/8 G 1/8 G 1/8 G 1/4 TN NPT 1/8 NPT 1/8 NPT 1/8 NPT 1/4 CY3B15 CY3B20 CY3B25 CY3B32 CY3B40 b C H B d M10 x 1.0 M20 x 1.5 M26 x 1.5 M32 x 2.0 H 4 8 8 10 B 14 26 32 41 C 16.2 30 37 47.3 Part No.

PBT 2 B Port plug 2 Bonnet PBT, HNBR Refer to page 705.

250 0 50 100 150 200 250 Supply pressure (kPa) Supply pressure (kPa) Detection side piping: 6 x 4 tubing 5 m Detection nozzle: 1.5 Detection side piping: 6 x 4 tubing 5 m Detection nozzle: 1.5 0.6 0.4 0.5 mm 0.25 mm 0.5 Detection distance (mm) Detection distance (mm) 0.3 0.4 0.3 0.2 0.15 mm 0.2 0.15 mm 0.1 0.1 0.03 mm 0.01 mm 0 0 0 50 100 150 200 250 0 50 100 150 200 250 Supply pressure

top ported R 3 4 A 4 A 4 A 4 A 4 A 4 A 4 A 4 A 39.5 (58.1) 62.1 41.7 25.7 2 B 2 B 2 B 2 B 2 B 2 B 2 B 2 B 20.9 P 1 P=17.5 63.3 44.5 7.5 One-touch fitting [4(A), 2(B) port] Applicable tubing O.D.: 4 : 6 : 8 L n Formula: L1 = 17.5n + 52, L2 = 17.5n + 74.5 n: Stations (Max. 16 stations) Dimensions 16 332 354.5 375 385.5 15 314.5 337 362.5 373 14 297 319.5 350 360.5 13 279.5 302 325 335.5 12

When selecting a converter by its nominal diameter, the converters oil level speed should be 0.2 m/s or less. 25 600 500 400 100 CRA1H100-180 200 20 CRA1H100-90 300 300 100 CRA1H80-180 200 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 200 150 CRA1H80-90 50 CRA1H63

[mm] Model L A B n D E 11-LEFG40-S-150 354 157 328 4 150 11-LEFG40-S-200 404 207 378 6 2 300 11-LEFG40-S-250 454 257 428 11-LEFG40-S-300 504 307 478 11-LEFG40-S-350 554 357 528 8 3 450 11-LEFG40-S-400 604 407 578 11-LEFG40-S-450 654 457 628 11-LEFG40-S-500 704 507 678 10 4 600 11-LEFG40-S-550 754 557 728 11-LEFG40-S-600 804 607 778 Model L A B n D E 11-LEFG40-S-650 854 657 828 12 5 750

Motor mounting process M5 x 14 Tightening torque 4.4Nm0.2Nm M4 x 14 Tightening torque 2.1Nm0.1Nm Plate A M4 x 14 M4 x 12 B 22 22 B section detail A section detail 18 Electric Actuator/Maintenance Guide 3 Be sure to read before handling. Belt mounting procedure Belt mounting process Belt mounting process 1. Confirm that the belt to be used has the following part number.

Side support B MY-SB 2 x J MY1B MY1B MY1H E A B MY1B C D MY1M (mm) MY1C A 61 70 87 B C D E F G H J Part no.

Hs A 26 B A 29 B D-B54 D-K59 / G59 Auto switch Auto switch 12 approx. Hs 12 approx.

-A22 ZPT125 50-(B/N/T)01-A22 ZPT125 75-(B/N/T)01-A22 ZPT125 100-(B/N/T)01-A22 ZPB-T1 25-(B/N/T)01 ZPB-T1 50-(B/N/T)01 ZPB-T1 75-(B/N/T)01 ZPB-T1 25-(B/N/T)01 ZPB-T1 50-(B/N/T)01 ZPB-T1 75-(B/N/T)01 ZPB-T2 25-(B/N/T)01 ZPB-T2 50-(B/N/T)01 ZPB-T2 75-(B/N/T)01 ZPB-T2 25-(B/N/T)01 ZPB-T2 50-(B/N/T)01 ZPB-T2 75-(B/N/T)01 ZPB-T3 25-(B/N/T)01 ZPB-T3 50-(B/N/T)01 ZPB-T3 75-(B/N/T)01 ZPB-T3 100-(B