A B A B A B A A A B For the I/O Unit part number mounted, refer to the following pages.
A B B A A B A B A 32.5 25 24.5 35 8.5 32 32 4.5 9.5 12 8 5.5 0 1.5 2 13 36.5 27.5 27.5 38.5 8.5 40 40 4.5 9.5 12 8 5.5 0 1.5 2 13 41 34 34.5 43.5 9 50 50 5 10 14 10 7.5 0 3.5 2.5 15 46 39 39.5 48.5 9 63 63 5 10 14 10 7.5 0 3.5 2.5 15 52.5 46.5 46.5 55 13 80 80 9 14 15.5 11.5 9 2.5 5 6.5 16.5 59.5 55 55 62 13 100 100 9 14 15.5 11.5 9 2.5 5 6.5 16.5 12 Series MDNB Auto Switch Internal Circuits
E AKM3000-A 1/8, 1/4 53 34 14 48 13 AC25-B AC30-B, AC30A-B AKM4000-A 1/4, 3/8 70 42 18 54 15 AC40-B, AC40A-B1 IN OUT B 1 Cannot be mounted on the AC40l-06-B.
B B B AC20-D 1/8 1/8 M5 x 0.8 Width across flats 14 Width across flats 14 N.O.: Black N.C.: Gray B AC30-D to AC60-D B B B B B B Thread type/Rc, G: 10 One-touch fitting Thread type/NPT: 3/8" One-touch fitting Barb fitting applicable tubing: T0604 1/4 1/4 1/4 Width across flats 17 Width across flats 17 Width across flats 17 Standard specifications Bracket mount P1 P2 A B C E F G J K M N Q1
with square flats Nh9 Release point RA (Dual arm) XA RR RB (Right arm) RC (Left arm) XB R XC RW LB PB0.02 PD0.05 PC0.05 PA0.02 GC LA0.1 GB L C 2 x 2 x PH7 Depth D 2 x 2 x MM Depth J Hexagon socket head plug 2 x 2 x NPT 1/4 G Rc GA E B RD (mm) Bore size (mm) B C D E GA GC J L LA LB MM N P GB 50 63 92 48 12 13.7 95 166 95.5 12 376.6 155.5 78.4 M8 x 1.25 19 8 110 54 15 16.6 99 171.5 100.5 12
Ambient temperature (C) Recommended circulating fluids 10 to 45 Tap water, ethylene glycol aqueous solution 15(wt)% -5 to 10 Ethylene glycol aqueous solution 15(wt)% -20 to -5 Ethylene glycol aqueous solution 40(wt)% Circulating fluid temperature(C) Recommended circulating fluids 10 to 35 Tap water, ethylene glycol aqueous solution 15(wt)% 5 to 10 Ethylene glycol aqueous solution 15(wt)%
A C D-F9 D-F9W D-M9 D-A93 D-A90 D-A96 D-F9V D-F9WV Bore size (mm) CXSJ15 to 32 B D A 15.5 25.5 31.5 39 40 49 D 9.5 7 0 3 5 5.5 C 9.5 19.5 25.5 33 34 43 B 6 9 11 11.5 B 0.5 3 10 13 15 15.5 D 7.5 5 2 5 7 7.5 A 15.5 25.5 31.5 39 40 49 A 19.5 29.5 35.5 43 44 53 C 11.5 21.5 27.5 35 36 45 D 5.5 3 4 7 9 9.5 D 8 5.5 1.5 4.5 6.5 7 B 6 9 11 11.5 B 0.5 3 10 13 15 15.5 C 13.5 23.5 29.5 37 38
For details, refer to page 9-15-68. Normally closed (NC = b contact), solid state switch (D-Y7G/Y7H type) are also available. For details, refer to page 9-15-42. 9-8-22
26 214 162 188 15 90 120 25 MX Pivot Bracket for Double Clevis MXU MXS MXQ MXF MXW MXP MG MGP Rotation Angle MGQ Bore size (mm) A B A+B+90 40 to 100 MGG 12 60 162 Note) The dimensions above are for reference.
For specifications, refer to page 9-15-66. Normally closed (NC = b contact), solid state switch (D-Y7G/Y7H type) are also available.
Refer to page 4-18-4.) 15 or less Applicable for vacuum use 100 kPa Max. operating frequency (Hz) 15 Flow Characteristics Refer to the table below. Non-locking push type Manual override Lubrication Mounting orientation Shock/Vibration resistance (m/s2) (2) Not required Unrestricted 300/50 Dustproof Note 1) Based on dynamic performance test, JIS B 8374-1981.
thread Uni thread size Wrench tightening angle after hand-tightening [deg] Tightening torque [Nm] 1/8 30 to 45 3 to 4 1/4 15 to 30 4 to 5 3/8 15 to 30 8 to 9 1/2 15 to 30 14 to 15 By chamfering as shown in the table below, machining of threads is easier and effective for burr prevention.
Gear transmission Number of teeth = a 1.Find the moment of inertia IB for the rotation of shaft (B). 2.Next, IB is entered to find IA the moment of inertia for the rotation of shaft (A) as I = m 12 a + b b a IA = ( )IB Number of teeth = b 15 Technical Data/Moment of Inertia C Moment of Inertia Calculation Examples Rotational Axis at Random Point in Load 1 Example) When load is a rectangular
(Except RSQ) 10-8-2 3 Stopper Cylinder: Fixed Mounting Height Series RSQ 12, 16, 20, 32, 40, 50 How to Order RE A B Without auto switch B RSQ 20 15 D REC CX J79W 20 15 RSDQ With auto switch B D CY Number of auto swiches Auto switch Built-in magnet MQQ M Nil Without auto switch Nil S 2 pcs. 1 pc.
Optional specifications (2) With barb fitting B 161 161 195 195 272 287 288 With drain guide B 160 160 194 194 271 286 287 Metal bowl B 85 123 166 166 200 200 276 292 293 Metal bowl with level gauge Model B 186 186 220 220 296 312 313 AC10 AC20 AC25 AC30 AC40 AC40-06 AC50 AC55 AC60 14-2-15 16 F.R.L.
For details, refer to page 9-15-66. Normally closed (NC = b contact), solid state switch (D-F9G/F9H type) are also available. For details, refer to page 9-15-39. 9-10-28
C A B C A B C Work load [kg] 2.5 5 10 4.5 9 18 1.2 2.5 5 Pushing force 65% 85% 95% Set value of pushing force [%] Ambient temperature Set value of pushing force* [%] Duty ratio [%] Continuous pushing time [minute] 25C or less 85 or less 100 40C 65 or less 100 85 50 15 * Set values for the controller. 230 AC Servo Motor Electric Actuator/Rod Type LEY/LEY-X5 Series Dust-tight/Water-jet-proof
-M3 X 0.5 thread depth 6 (A, B, C common view) 3-3 depth 6 +0.02 0 34 (A, B, C common view) 12h9 0 -0.043 1.5 5 19.5 12 41.5 (45) 0 8 17 2 0 8 -0.05 2 3.5 0 -0.03 3.5 0 -0.03 Open: 22 Closed: 14 2-M3 X 0.5 thread depth 6 (Thread for mounting attachment) 15 15 6 5 5 6 SMH3, #6 2.3-11 2 Finger Air Gripper Series MHR2/MDHR2 With Auto Switch (Built-in magnet): MDHR2-15R P.C.D29 (Mounting thread
L 15 16 L+ L+ 16 17 L L+ 18 Notes 1.