Magnet: Built-in, Mounting: Double Clevis, Style: Aluminum Tube, Bore Size: 100mm, Thread: Rc, Stroke: 600mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: Spring/Air Pressure Lock, Auto Switch: -, Lead Wire or Prewied Connector: -, Number: -
Magnet: Built-in, Mounting: Double Clevis, Style: Aluminum Tube, Bore Size: 100mm, Thread: Rc, Stroke: 700mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: Spring/Air Pressure Lock, Auto Switch: -, Lead Wire or Prewied Connector: -, Number: -
Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 150, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Cushion: None, Operating Pressure(MPa): -, Specification: -, Port thread type:
Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 200, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Cushion: With cushions on both sides, Operating Pressure(MPa): 0.08 to 1.0, Specification
Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 305, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Cushion: With cushions on both sides, Operating Pressure(MPa): 0.08 to 1.0, Specification
Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 550, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Cushion: With cushions on both sides, Operating Pressure(MPa): 0.08 to 1.0, Specification
Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 800, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Cushion: None, Operating Pressure(MPa): -, Specification: -, Port thread type:
C D 15 (mm) Auto switch model A D-F9 B C D D-A9 D-F9 D-A9 D-F9 D-A9 D-F9 Bore size (mm) 17.5 15 D-A9 21.5 76.5 72.5 56.5 60.5 Note) Auto switches cannot be installed in Area C in the case of 15. 25, 32 (mm) A D-Y5 D-Y7 D-Y7W B C D Auto switch model D-Y5 D-Y7 D-Y7W D-Y5 D-Y7 D-Y7W D-Y5 D-Y7 D-Y7W D-Z7 D-Z8 D-Z7 D-Z8 D-Z7 D-Z8 D-Z7 D-Z8 Bore size (mm) 25 22 101 103 47 47 78 78 22 32 30.5
lines indicate DIN rail mount type [-D] and connector top entry [-JU].
They can be ordered in lots of 10 pieces. d D Series SY3000 SY5000 SY7000 Part No.
Series Variations Applicable auto switch models Standard variations Lock system Standard stroke (mm) Bore size (mm) Solid state switch Reed switch Type Model Action Series Built-in auto switch magnet With rod boot Spring lock Grommet Grommet Mounting 3 wire 3 wire 2 wire D-F59 D-F59W D-J59W D-F5P D-F5PW D-F5BAL (2 color indicator) (2 color indicator) 2 wire 4 wire 3 wire D-J59 D-F59F D-F5NTL
P1 Control Circuit Power Supply Connector: CNP2 Accessory P2 Terminal name Function Function details P P C D L11 L21 Connect between P and D. (Connected at time of shipping.) If regeneration option is required for Model Selection, connect to this terminal.
SMC Pneumatics, Inc. 8 Series ASIII1F-T Dimensions (mm) 1in=25.4mm L4 D3 Applicable tubing O.D. d L3 D1 L2 M1 M1 D2 L1 Metric sizes Inch sizes Model d D1 D2 D3 L1 L2 L3 L4 M1 M1 Model d D1 D2 D3 L1 L2 L3 L4 AS1001F-01T 1/8" 8.4 38 4.5 26 AS1001F-23T 3.2 8.4 38 4.5 26 12.7 12.7 AS1001F-03T 5/32" 9.3 39.2 5.2 26.6 AS1001F-04T 4 10 4.5 0.7 9.3 39.2 5.2 26.6 10 4.5 0.7 AS1001F-05T 3/16" AS1001F
MY CY Proper Auto Switch Mounting Position MG Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com A B Auto switch model CX D-Y5 D-Y6 D-Y7P D-Y7PV D-Y5 D-Y6 D-Y7P D-Y7PV D-Z7 D-Z80 D-Y7W D-Y7WV D-Y7W D-Y7WV D-Z7 D-Z80 DCylinder model CYP15 93.5 24.5 -X CYP32 122 33 20Data
NUZ322GOHOO-lt5 DIN connctor (D)/ NIf4|220-ODOO5 ftft E g !
NUZ322GOHOO-lt5 DIN connctor (D)/ NIf4|220-ODOO5 ftft E g !
Applicable fluids TL D DIN connector DIN connector with indicator light DL 6, 7, 9.
(Make sure that there is no rotation backlash in the table.) 3 Tighten both adjustment bolts c and d to approx. 45. Note 1) Tighten both adjustment bolts c and d to approx. 45. Note 1) 4 Lock adjustment bolts c and d with fixing nuts. Note 2) Lock adjustment bolts c and d with fixing nuts.