Size, Body, Valve Type: 15D (Size: 1; Body Mat'l: C37; Port Size: 1/4; Orifice Dia: 2, N.C.), Voltage and Electrical Entry: J (110VAC; DIN Terminal w/Surge Voltage Suppressor), Other Voltages and Electrical Options: None, Other Options: B (NPT Thread)
Size, Body, Valve Type: 15D (Size: 1; Body Mat'l: C37; Port Size: 1/4; Orifice Dia: 2, N.C.), Voltage and Electrical Entry: G (24VDC; DIN Terminal w/Surge Voltage Suppressor), Other Voltages and Electrical Options: None, Other Options: B (NPT Thread), Mounting: XC (Special Entry Direction), Electrical Entry Direction: B (180°)
Size, Body, Valve Type: 15D (Size: 1; Body Mat'l: C37; Port Size: 1/4; Orifice Dia: 2, N.C.), Voltage and Electrical Entry: G (24VDC; DIN Terminal w/Surge Voltage Suppressor), Other Voltages and Electrical Options: None, Other Options: Rc, Mounting: XB (w/Bracket)
This is a legacy product, and replaced byCDJP2B6-15D-A93
The latest version can be found hereCDJP2B10-15D-A90, CYL, PIN, DBL ACT, A-SW *LQA, ACTUATOR, CJP/CJP2 ROUND BODY CYLINDER, ED, 10MM CJP/CJP2 DOUBLE-ACTING, .18480 lb
This is a legacy product, and replaced byCDJP2B16-15D
This is a legacy product, and replaced byCDJP2B6-15D
ZSE2-0R-15 Air 0 to 101 kPa 3% or less 3% Full span (5 to 40C) 5% Full span (0 to 60C) 12 to 24 VDC (Ripple 10% or less) Open collector 30 V, 80 mA Lights up when ON 17 mA or less (when 24 VDC is ON) 0.2 MPa Fluid Setting pressure range Hysteresis Compact size: 39H x 20W x 15D (except the connecting portion) ZX Temperature characteristics Improved wiring: Connector style Operating voltage
Do not expose it to direct sunlight. 13-2-12 12 Vacuum Module: Ejector System Series ZX Vacuum Pressure Switch Unit/Vacuum Pressure Switch: ZSE2-0X Vacuum Pressure Switch Quick response: 10 ms Compact size: 39H x 20W x 15D (except the connecting portion) Improved wiring: connector type Uses a carrier diffusion semiconductor pressure sensor ZSE2-0X Air 0 to 101 kPa 3% Full span or less 3%
This is a legacy product, and replaced byCDJP2F6-15D-B-A93S
This is a legacy product, and replaced byCDJP2B10-15D
SMC has redesigned the CQ2 compact cylinder with a new body, making it possible to mount auto switches on any of the 4 surfaces, depending on the installation conditions. Auto switch mounting grooves have replaced the CQ2s mounting rails, preventing projection of auto switches and improving ease and safety of work.Double acting, single rod, compact cylinder, Bore sizes *: 12, 16, 20, 25,
Magnet: Built-in Magnet, Mounting: Through-hole, Standard, Bore Size: 16mm, Port Thread: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 30mm, Body Option: Standard, Rod End Female Thread, Auto Switch Groove: None (for 12-25 Bore w/o Magnet; 32-100 Bore w/o Magnet Z must be selected), Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number
Magnet: Built-in Magnet, Mounting: Through-hole, Standard, Bore Size: 16mm, Port Thread: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 20mm, Body Option: Standard, Rod End Female Thread, Auto Switch Groove: None (for 12-25 Bore w/o Magnet; 32-100 Bore w/o Magnet Z must be selected), Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number
Magnet: Built-in Magnet, Mounting: Through-hole, Standard, Bore Size: 16mm, Port Thread: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 25mm, Body Option: Standard, Rod End Female Thread, Auto Switch Groove: None (for 12-25 Bore w/o Magnet; 32-100 Bore w/o Magnet Z must be selected), Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number
Cylinder (Tube) Inner Diameter(φ): 16, Stroke(mm): 15, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.07~1, Cushion: None, Specification: Built-in magnet, Support bracket:
Cylinder (Tube) Inner Diameter(φ): 16, Stroke(mm): 20, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.07~1, Cushion: None, Specification: Built-in magnet, Support bracket:
Cylinder (Tube) Inner Diameter(φ): 16, Stroke(mm): 15, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.07~1, Cushion: None, Specification: Built-in magnet, Support bracket:
Cylinder (Tube) Inner Diameter(φ): 16, Stroke(mm): 20, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.07~1, Cushion: None, Specification: Built-in magnet, Support bracket:
(Or None in the Case of No Switch), Environmental Options: XB14 (w/Heat Resistant Auto Switch)