Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.07~1, Cushion: None, Specification: Built-in magnet, Support bracket: Both ends tapped, Port thread type: Metric, Body Options: -, Auto Switches: M9NW
Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in magnet, Support bracket: Both ends tapped, Port thread type: Metric, Body Options: -, Auto Switches: M9NW
(It goes for replacing retainer assembly for Series CS1.) 6-17-41 35 Made to Order Common Specifications: With Heavy Duty Scraper Made to Order Common Specifications: -XC4: With Heavy Duty Scraper Symbol -XC4 With Heavy Duty Scraper 12 Dimensions Construction (Dimensions are the same as standard.)
SMC has redesigned the CQ2 compact cylinder with a new body, making it possible to mount auto switches on any of the 4 surfaces, depending on the installation conditions. Auto switch mounting grooves have replaced the CQ2s mounting rails, preventing projection of auto switches and improving ease and safety of work.Double acting, single rod, compact cylinder, Bore sizes *: 12, 16, 20, 25
Made to Order Symbol Combination Symbol Description Applicable shaft type Applicable size W, J, K, S, T, Y XC1* Add connecting ports 10, 15, 20, 30, 40 XC2* Change threaded holes to through-holes 15, 20, 30, 40 XC3* Change the screw position Symbol Combination XC1 XC1 XC2 XC2 XC3 XC3 XC4 XC4 XC5 XC5 XC6 XC6 XC7 XC7 XC30 X5 XC4 Change the rotation range XC5* Change rotation range between
-XC4 6 With Heavy Duty Scraper Stroke M L MGP XC4 Bore size Specifications Applicable series MGPM, MGPL With heavy duty scraper Scraper specification Bearing type Slide bearing, Ball bushing Cylinder bore size (mm) 20, 25, 32, 40, 50, 63, 80, 100 Nil W Single side scraper Double side scrapers Single side 0.12MPa (17 psi) Minimum operating pressure Double side With a heavy duty scraper used
(Or None in the Case of No Switch), Environmental Options: XC4 (Heavy Duty Scraper)
Magnet: Built-in Magnet, Mounting: Through-hole, Standard, Bore Size: 20mm, Port Thread: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 25mm, Body Option: Standard, Rod End Female Thread, Auto Switch Groove: None (for 12-25 Bore w/o Magnet; 32-100 Bore w/o Magnet Z must be selected), Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number
Magnet: Built-in Magnet, Mounting: Through-hole, Standard, Bore Size: 20mm, Port Thread: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 40mm, Body Option: Standard, Rod End Female Thread, Auto Switch Groove: None (for 12-25 Bore w/o Magnet; 32-100 Bore w/o Magnet Z must be selected), Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number
Magnet: Built-in Magnet, Mounting: Through-hole, Standard, Bore Size: 20mm, Port Thread: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 40mm, Body Option: Rod End Male Thread, Auto Switch Groove: None (for 12-25 Bore w/o Magnet; 32-100 Bore w/o Magnet Z must be selected), Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or
Magnet: Built-in Magnet, Mounting: Through-hole, Standard, Bore Size: 20mm, Port Thread: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 50mm, Body Option: Standard, Rod End Female Thread, Auto Switch Groove: None (for 12-25 Bore w/o Magnet; 32-100 Bore w/o Magnet Z must be selected), Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number
Magnet: Built-in Magnet, Mounting: Through-hole, Standard, Bore Size: 20mm, Port Thread: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 45mm, Body Option: Rod End Male Thread, Auto Switch Groove: None (for 12-25 Bore w/o Magnet; 32-100 Bore w/o Magnet Z must be selected), Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or
Magnet: Built-in Magnet, Mounting: Through-hole, Standard, Bore Size: 20mm, Port Thread: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 10mm, Body Option: Standard, Rod End Female Thread, Auto Switch Groove: None (for 12-25 Bore w/o Magnet; 32-100 Bore w/o Magnet Z must be selected), Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number
Magnet: Built-in Magnet, Mounting: Through-hole, Standard, Bore Size: 20mm, Port Thread: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 10mm, Body Option: Rod End Male Thread, Auto Switch Groove: None (for 12-25 Bore w/o Magnet; 32-100 Bore w/o Magnet Z must be selected), Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or
Magnet: Built-in Magnet, Mounting: Through-hole, Standard, Bore Size: 20mm, Port Thread: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 20mm, Body Option: Rod End Male Thread, Auto Switch Groove: None (for 12-25 Bore w/o Magnet; 32-100 Bore w/o Magnet Z must be selected), Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or
Magnet: Built-in Magnet, Mounting: Through-hole, Standard, Bore Size: 20mm, Port Thread: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 15mm, Body Option: with Rubber Bumper, Auto Switch Groove: None (for 12-25 Bore w/o Magnet; 32-100 Bore w/o Magnet Z must be selected), Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or
Magnet: Built-in Magnet, Mounting: Through-hole, Standard, Bore Size: 20mm, Port Thread: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 35mm, Body Option: Standard, Rod End Female Thread, Auto Switch Groove: None (for 12-25 Bore w/o Magnet; 32-100 Bore w/o Magnet Z must be selected), Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number
Magnet: Built-in Magnet, Mounting: Through-hole, Standard, Bore Size: 20mm, Port Thread: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 30mm, Body Option: Standard, Rod End Female Thread, Auto Switch Groove: None (for 12-25 Bore w/o Magnet; 32-100 Bore w/o Magnet Z must be selected), Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number
Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 10, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in magnet, Support bracket:
Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 10, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in magnet, Support bracket: