Made to order options (see Page 55) Low temperatureresistant (XB6) resistant Modification of rod end auto switch Page P 8 P 1 7 P32 fechnical Data Auto switch guide P 4 6 P 3 8 ?

Stainless Steel Body for Low Breakway Friction Double Roc/Double End Mounting 6 Available Mounting Options Non-Rotating Option Auto Switch Capable Air Cylinder: Standard Type Series:NCM Series NCM How Toordcr NC DMrB075-02 00 C S J 851 xB6 T r I Lo**" Auto-Switch Capable I xB6 -High Temp. I XB7 -Low Temp.

Made to order options (see Page 55) Low temperatureresistant (XB6) resistant Modification of rod end auto switch Page P 8 P 1 7 P32 fechnical Data Auto switch guide P 4 6 P 3 8 ?

Silrc" lrcyrinder -NCM seies Stainless Steel Cylinders Stainless Steel Body for Low Breakway Friction Double Rod/Double End Mounting 6 Available Mounting Options Non-Rotating Option Auto Switch Capable Air Cylinder: Standard Type Series:NCM Series NCM How Toordcr NC DMrB075-02 00 C S J 851 xB6 T r I Lo**" Auto-Switch Capable I xB6 -High Temp. I XB7 -Low Temp.

Magnet: None, Mounting: Both Ends Tapped, Bore Size: 63mm, Port Thread: NPT; 32 to 100 Bore, Stroke: 75mm, Body Option: Standard, Rod End Female Thread, Auto Switch Groove: ø12 to ø25, 2 Surfaces; ø32 to ø100, 4 Surfaces, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Environmental Options

Cylinder (Tube) Inner Diameter(φ): 63, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Without built-in magnet, Support

Cylinder (Tube) Inner Diameter(φ): 63, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Without built-in magnet, Support

Cylinder (Tube) Inner Diameter(φ): 63, Stroke(mm): 125, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Without built-in magnet, Support

Magnet: None, Mounting: A (Both Ends Tapped), Bore Size: 63mm, Port Thread Type: TN (NPT 32-100 Bore), Stroke: 15mm, Body Option: Standard (Rod End Female Thread), Auto Switch Groove: Z (Auto Switch Mounting Grooves)

Magnet: None, Mounting: A (Both Ends Tapped), Bore Size: 63mm, Port Thread: TN (NPT; 32 to 100 Bore), Stroke: 75mm, Body Option: Standard, Rod End Female Thread, Auto Switch Groove: Z (ø12 to ø25, 2 Surfaces; ø32 to ø100, 4 Surfaces), Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Environmental

Magnet: None, Mounting: A (Both Ends Tapped), Bore Size: 63mm, Port Thread: TN (NPT; 32 to 100 Bore), Stroke: 25mm, Body Option: Standard, Rod End Female Thread, Auto Switch Groove: Z (ø12 to ø25, 2 Surfaces; ø32 to ø100, 4 Surfaces), Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Environmental

Magnet: None, Mounting: A (Both Ends Tapped), Bore Size: 63mm, Port Thread: TN (NPT; 32 to 100 Bore), Stroke: 50mm, Body Option: Standard, Rod End Female Thread, Auto Switch Groove: Z (ø12 to ø25, 2 Surfaces; ø32 to ø100, 4 Surfaces), Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Environmental

Magnet: None, Mounting: Both Ends Tapped, Bore Size: 63mm, Port Thread Type: NPT 32-100 Bore, Stroke: 15mm, Body Option: Standard (Rod End Female Thread), Auto Switch Groove: Auto Switch Mounting Grooves, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -

Cylinder (Tube) Inner Diameter(φ): 63, Stroke(mm): 125, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Without built-in magnet, Support

Magnet: None, Mounting: Both Ends Tapped, Bore Size: 63mm, Port Thread: NPT; 32 to 100 Bore, Stroke: 25mm, Body Option: Standard, Rod End Female Thread, Auto Switch Groove: ø12 to ø25, 2 Surfaces; ø32 to ø100, 4 Surfaces, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Environmental Options

SMC has redesigned the CQ2 compact cylinder with a new body, making it possible to mount auto switches on any of the 4 surfaces, depending on the installation conditions. Auto switch mounting grooves have replaced the CQ2s mounting rails, preventing projection of auto switches and improving ease and safety of work.Double acting, single rod, compact cylinder, Bore sizes *: 12, 16, 20, 25,

SMC has redesigned the CQ2 compact cylinder with a new body, making it possible to mount auto switches on any of the 4 surfaces, depending on the installation conditions. Auto switch mounting grooves have replaced the CQ2s mounting rails, preventing projection of auto switches and improving ease and safety of work.Double acting, single rod, compact cylinder, Bore sizes *: 12, 16, 20, 25,

Direct mount type CY3R Series Basic type CY3B Series Series Variations Standard stroke (mm) Individual Made-to-Order products Bore size 1000 900 800 700 600 500 450 400 350 300 250 200 150 100 50 Series Heat resistant specifications (XB6) Low speed specifications (15 to 50 mm/s) (XB9) 6 10 Long stroke (XB11) 15 Low speed specifications (7 to 50 mm/s) (XB13) 20 CY3B Hydro specifications (X116

The length of lead between the switch body and the contact protective box should be within 1 m and they should be set as close together as possible. 6-10-45 46 Series C76 1 High Temperature XB6 2 Low Temperature XB7 C76 Mounting Bore size Stroke XB7 C76 Mounting Bore size Stroke XB6 E, F , Y 32, 40 mm E, F , Y 32, 40 mm Standard cylinder packing are replaced with special ones and other

A solid state magnetic field resistant auto switch is available. (40, 50, 63) DFull stroke -X Clamp stroke 20Data Made to Order Specifications Heat resistant: Max. 150C (-XB6) 10-7-1 2 Series MK/MK2 Precautions 1 Be sure to read before handling. For Safety Instructions and Actuator Precautions, refer to pages 10-24-3 to 10-24-6.