D-A73, D-A80 D-A72H, O.A73H, O.A76H, D-A8OH, D-F7NTL, D-F7P, D-F79, D.F79W, O-J79, D..t79W D-Fltr WV, D-F7tr V t,.A73C, D-A80C, D-J79C op6drirE ElE6 (* lid be*rw) I, Dimensiltn / Operating Range Series NCDQT Solid.
D-A6 o D-A73 & D-A53 0or 24VDC) have a lighr emitting diode as an indicator light, and thsrefore, have poladty. lf using 24VDC, the black lead Wire is (-) side, and the red lead is (+) side. lf connection is revrsed, the light will not go on ahhough the switch wi operate.
Order with the part number “CDQ2B50-30DCZ-BQ,” which includes the current cylinder as well as 2 D-A73 auto switch mounting brackets. If you have already purchased a CDQ2B50-30DCZ, please order the 2 D-A73 mounting brackets using the part number “BQ5-032.”
32 to 50 Hs A Hs A B Hs A B B Hs D-P3DWA B B Hs B B Hs B Hs A 572 A A A Auto Switch Mounting RSQ Series Auto Switch Proper Mounting Position (Detection at Stroke End) and Its Mounting Height Auto Switch Proper Mounting Position (mm) Auto switch model D-A72/A7H/A80H D-A73C/A80C D-F7/J79 D-F7V/J79C D-F7BAV/F7BA D-F7W/J79W D-F7WV/F79F D-M9 D-M9V D-M9W D-M9WV D-M9A D-M9AV D-A9 D-A9V D-A73
D-A73, D-A80 D-A72H, O.A73H, O.A76H, D-A8OH, D-F7NTL, D-F7P, D-F79, D.F79W, O-J79, D..t79W D-Fltr WV, D-F7tr V t,.A73C, D-A80C, D-J79C op6drirE ElE6 (* lid be*rw) I, Dimensiltn / Operating Range Series NCDQT Solid.
D-A6 o D-A73 & D-A53 0or 24VDC) have a lighr emitting diode as an indicator light, and thsrefore, have poladty. lf using 24VDC, the black lead Wire is (-) side, and the red lead is (+) side. lf connection is revrsed, the light will not go on ahhough the switch wi operate.
With no external leakage, the CY series can be used in many diverse environments. Magnetically coupled cylinders have a wide range of applications, and save mounting space. Loads and moments are possible through the use of integrated guides. A variety of guides can be used to achieve the necessary accuracy or allowable moment needed for your application. CY is available in 9 bore sizes,
With no external leakage, the CY series can be used in many diverse environments. Magnetically coupled cylinders have a wide range of applications, and save mounting space. Loads and moments are possible through the use of integrated guides. A variety of guides can be used to achieve the necessary accuracy or allowable moment needed for your application. CY is available in 9 bore sizes,
Bore Size: 15mm, Port Thread: Rc (or M Thread for 6 to 15 Bore), Magnetic Holding Force: H (Large Holding Force), Stroke: 100mm, Adjuster: Adjuster Bolt, Auto Switch: J79C--Solid State, Gen. Purpose, 2 Wire, Connector, Vertical, Lead Wire or Prewired Connector: L (3m)
Bore Size: 15mm, Port Thread: Rc (or M Thread for 6 to 15 Bore), Magnetic Holding Force: H (Large Holding Force), Stroke: 250mm, Adjuster: Adjuster Bolt, Auto Switch: A73--Reed, DC Volt.>5,<24, AC Volt.<100, LED, Lead Wire, Vertical, Lead Wire or Prewired Connector: L (3m)
Bore Size: 15mm, Port Thread: Rc (or M Thread for 6 to 15 Bore), Magnetic Holding Force: H (Large Holding Force), Stroke: 300mm, Adjuster: B (Shock Absorbers (2 pcs)), Auto Switch: A73H--Reed, DC Volt.>5,<24, AC Volt.<100, LED, Lead Wire, Horizontal, Lead Wire or Prewired Connector: Z (5m), Number: S (1 pc.)
Bore Size: 15mm, Port Thread: Rc (or M Thread for 6 to 15 Bore), Magnetic Holding Force: H (Large Holding Force), Stroke: 400mm, Adjuster: B (Shock Absorbers (2 pcs)), Auto Switch: A73--Reed, DC Volt.>5,<24, AC Volt.<100, LED, Lead Wire, Vertical, Lead Wire or Prewired Connector: L (3m)
Bore Size: 15mm, Port Thread: Rc (or M Thread for 6 to 15 Bore), Magnetic Holding Force: H (Large Holding Force), Stroke: 50mm, Adjuster: Adjuster Bolt, Auto Switch: F7P--Solid State, Gen. Purpose, 3 Wire PNP, Lead Wire, Horizontal, Lead Wire or Prewired Connector: L (3m)
Bore Size: 15mm, Port Thread: Rc (or M Thread for 6 to 15 Bore), Magnetic Holding Force: H (Large Holding Force), Stroke: 50mm, Adjuster: B (Shock Absorbers (2 pcs)), Auto Switch: F7P--Solid State, Gen. Purpose, 3 Wire PNP, Lead Wire, Horizontal, Lead Wire or Prewired Connector: L (3m)
Bore Size: 15mm, Port Thread: Rc (or M Thread for 6 to 15 Bore), Magnetic Holding Force: H (Large Holding Force), Stroke: 750mm, Adjuster: B (Shock Absorbers (2 pcs)), Auto Switch: F7BV--Solid State, Gen. Purpose, 2 Wire, Lead Wire, Vertical, Lead Wire or Prewired Connector: L (3m)
Bore Size: 15mm, Port Thread: Rc (or M Thread for 6 to 15 Bore), Magnetic Holding Force: H (Large Holding Force), Stroke: 350mm, Adjuster: B (Shock Absorbers (2 pcs)), Auto Switch: A73--Reed, DC Volt.>5,<24, AC Volt.<100, LED, Lead Wire, Vertical, Lead Wire or Prewired Connector: L (3m)
Bore Size: 15mm, Port Thread: Rc (or M Thread for 6 to 15 Bore), Magnetic Holding Force: H (Large Holding Force), Stroke: 250mm, Adjuster: B (Shock Absorbers (2 pcs)), Auto Switch: A73--Reed, DC Volt.>5,<24, AC Volt.<100, LED, Lead Wire, Vertical, Lead Wire or Prewired Connector: L (3m)
Bore Size: 15mm, Port Thread: Rc (or M Thread for 6 to 15 Bore), Magnetic Holding Force: H (Large Holding Force), Stroke: 300mm, Adjuster: B (Shock Absorbers (2 pcs)), Auto Switch: A73--Reed, DC Volt.>5,<24, AC Volt.<100, LED, Lead Wire, Vertical, Lead Wire or Prewired Connector: Z (5m)
Bore Size: 15mm, Port Thread: Rc (or M Thread for 6 to 15 Bore), Magnetic Holding Force: H (Large Holding Force), Stroke: 300mm, Adjuster: B (Shock Absorbers (2 pcs)), Auto Switch: J79--Solid State, Gen. Purpose, 2 Wire, Lead Wire, Horizontal, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 3 pcs.
Bore Size: 15mm, Port Thread: Rc (or M Thread for 6 to 15 Bore), Magnetic Holding Force: H (Large Holding Force), Stroke: 150mm, Adjuster: B (Shock Absorbers (2 pcs)), Auto Switch: A73C--Reed, DC Volt.>5,<24, LED, Connector, Vertical, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 4 pcs.