SMC Corporation of America
Elite Part Number Search
Search Results "CY1L20H-150-A73"

Note 2) These figures show the dimensions when equipped with D-A73 or D-A80 auto switches.

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, RODLESS, ACTUATOR, CY1H/CY1L GUIDED CYLINDER, HE, 20MM CY1H/CY1L DBL-ACT A/S, 3.30693 lb, Bore size (mm)ModelAllowable load mass (Wv)(kg)Maximum operating pressure (Pv)(MPa)20CY1L20H11.00.65

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, RODLESS, ACTUATOR, CY1H/CY1L GUIDED CYLINDER, HE, 20MM CY1H/CY1L DBL-ACT A/S, 7.30673 lb, Bore size (mm)ModelAllowable load mass (Wv)(kg)Maximum operating pressure (Pv)(MPa)20CY1L20H11.00.65

With no external leakage, the CY series can be used in many diverse environments. Magnetically coupled cylinders have a wide range of applications, and save mounting space. Loads and moments are possible through the use of integrated guides. A variety of guides can be used to achieve the necessary accuracy or allowable moment needed for your application. CY is available in 9 bore sizes,

U B A Auto Switch Proper Mounting Positions (mm) Solid state auto switch Reed auto switch D-F7/J79 D-F7V/J79C D-F7W/F7WV D-F7BA/F7BAV D-F79F/J79W D-F7NT D-A9/A9V D-A73/A80 D-A7H/A80H D-A73C/A80C D-A72 D-A79W D-M9/M9V D-M9W/M9WV D-M9A/M9AV Bore size (mm) B 10.5 23 26 27.5 31.5 33 35.5 B 9.5 20.5 23.5 25 29 30.5 33 B 14.5 25.5 28.5 30 34 35.5 38 B 6.5 19 22 23.5 27.5 29 31.5 B 9 20 23 24.5

Applicable models: D-A93, A93V, D-A73, D-A73H, D-A73C 1) Even if connections are reversed on a 2-wire type switch, the switch will not be damaged because it is protected by a protection circuit, but it will remain in a normally ON state.

With no external leakage, the CY series can be used in many diverse environments. Magnetically coupled cylinders have a wide range of applications, and save mounting space. Loads and moments are possible through the use of integrated guides. A variety of guides can be used to achieve the necessary accuracy or allowable moment needed for your application. CY is available in 9 bore sizes,

With no external leakage, the CY series can be used in many diverse environments. Magnetically coupled cylinders have a wide range of applications, and save mounting space. Loads and moments are possible through the use of integrated guides. A variety of guides can be used to achieve the necessary accuracy or allowable moment needed for your application. CY is available in 9 bore sizes,

Bore Size: 20mm, Port Thread: Rc (or M Thread for 6 to 15 Bore), Magnetic Holding Force: H (Large Holding Force), Stroke: 200mm, Adjuster: Adjuster Bolt, Auto Switch: A73--Reed, DC Volt.>5,<24, AC Volt.<100, LED, Lead Wire, Vertical, Lead Wire or Prewired Connector: L (3m)

Bore Size: 20mm, Port Thread: Rc (or M Thread for 6 to 15 Bore), Magnetic Holding Force: H (Large Holding Force), Stroke: 250mm, Adjuster: B (Shock Absorbers (2 pcs)), Auto Switch: A73--Reed, DC Volt.>5,<24, AC Volt.<100, LED, Lead Wire, Vertical, Lead Wire or Prewired Connector: L (3m)

Bore Size: 20mm, Port Thread: Rc (or M Thread for 6 to 15 Bore), Magnetic Holding Force: H (Large Holding Force), Stroke: 300mm, Adjuster: B (Shock Absorbers (2 pcs)), Auto Switch: A72--Reed, AC Volt.<200, LED, Lead Wire, Vertical

Bore Size: 20mm, Port Thread: Rc (or M Thread for 6 to 15 Bore), Magnetic Holding Force: H (Large Holding Force), Stroke: 400mm, Adjuster: Adjuster Bolt, Auto Switch: A73C--Reed, DC Volt.>5,<24, LED, Connector, Vertical, Lead Wire or Prewired Connector: L (3m)

Bore Size: 20mm, Port Thread: Rc (or M Thread for 6 to 15 Bore), Magnetic Holding Force: H (Large Holding Force), Stroke: 400mm, Adjuster: B (Shock Absorbers (2 pcs)), Auto Switch: F79--Solid State, Gen. Purpose, 3 Wire NPN, Lead Wire, Horizontal, Lead Wire or Prewired Connector: L (3m)

Bore Size: 20mm, Port Thread: Rc (or M Thread for 6 to 15 Bore), Magnetic Holding Force: H (Large Holding Force), Stroke: 100mm, Adjuster: B (Shock Absorbers (2 pcs)), Auto Switch: F7P--Solid State, Gen. Purpose, 3 Wire PNP, Lead Wire, Horizontal, Lead Wire or Prewired Connector: L (3m)

Bore Size: 20mm, Port Thread: Rc (or M Thread for 6 to 15 Bore), Magnetic Holding Force: H (Large Holding Force), Stroke: 600mm, Adjuster: B (Shock Absorbers (2 pcs)), Auto Switch: A73--Reed, DC Volt.>5,<24, AC Volt.<100, LED, Lead Wire, Vertical, Lead Wire or Prewired Connector: L (3m)

Bore Size: 20mm, Port Thread: Rc (or M Thread for 6 to 15 Bore), Magnetic Holding Force: H (Large Holding Force), Stroke: 800mm, Adjuster: B (Shock Absorbers (2 pcs)), Auto Switch: A73H--Reed, DC Volt.>5,<24, AC Volt.<100, LED, Lead Wire, Horizontal, Lead Wire or Prewired Connector: L (3m)

Bore Size: 20mm, Port Thread: Rc (or M Thread for 6 to 15 Bore), Magnetic Holding Force: H (Large Holding Force), Stroke: 300mm, Adjuster: B (Shock Absorbers (2 pcs)), Auto Switch: F7P--Solid State, Gen. Purpose, 3 Wire PNP, Lead Wire, Horizontal, Lead Wire or Prewired Connector: L (3m)

Bore Size: 20mm, Port Thread: Rc (or M Thread for 6 to 15 Bore), Magnetic Holding Force: H (Large Holding Force), Stroke: 700mm, Adjuster: B (Shock Absorbers (2 pcs)), Auto Switch: A73H--Reed, DC Volt.>5,<24, AC Volt.<100, LED, Lead Wire, Horizontal, Lead Wire or Prewired Connector: L (3m)

Bore Size: 20mm, Port Thread: Rc (or M Thread for 6 to 15 Bore), Magnetic Holding Force: H (Large Holding Force), Stroke: 700mm, Adjuster: B (Shock Absorbers (2 pcs)), Auto Switch: A73C--Reed, DC Volt.>5,<24, LED, Connector, Vertical