Cooling Capacity: 012 (Cooling Capacity: 1100/1300W, 50/60 Hz), Cooling Method: A (Air-cooled Refrigeration), Thread: N (NPT w/PT-NPT Conversion Fitting Set), Option: BW (B + W)
Cooling Capacity: 012 (Cooling Capacity: 1100/1300W, 50/60 Hz), Cooling Method: W (Water-cooled Refrigeration), Thread: Rc, Option: MT (M + T)
Cooling Capacity: 012 (Cooling Capacity: 1100/1300W, 50/60 Hz), Cooling Method: W (Water-cooled Refrigeration), Thread: N (NPT w/PT-NPT Conversion Fitting Set), Option: MT (M + T)
Cooling Capacity: 012 (Cooling Capacity: 1100/1300W, 50/60 Hz), Cooling Method: W (Water-cooled Refrigeration), Thread: Rc, Option: B (Earth Leakage Breaker)
Cooling Capacity: 012 (Cooling Capacity: 1100/1300W, 50/60 Hz), Cooling Method: W (Water-cooled Refrigeration), Thread: F (G w/PT-G Conversion Fitting Set), Option: BJ (B + J)
Cooling Capacity: 012 (Cooling Capacity: 1100/1300W, 50/60 Hz), Cooling Method: A (Air-cooled Refrigeration), Thread: Rc, Option: B (Earth Leakage Breaker)
Cooling Capacity: 012 (Cooling Capacity: 1100/1300W, 50/60 Hz), Cooling Method: W (Water-cooled Refrigeration), Thread: N (NPT w/PT-NPT Conversion Fitting Set), Option: BJM (B + J + M)
Cooling Capacity: 012 (Cooling Capacity: 1100/1300W, 50/60 Hz), Cooling Method: A (Air-cooled Refrigeration), Thread: N (NPT w/PT-NPT Conversion Fitting Set), Option: BMT (B + M + T)
L 100mm, or stroke 1 2 1 7 5 4 6 2 6 5 7 3 L L Fig. 9 Position for application of grease Table 10 Amount of grease units: g Stroke 40 50 63 80 100 P o s i t i o n f o r Bore g r e a s e At 100st 3 to 4 3 to 5 4 to 5 6 to 8 8 to 10 50st added 1 1 1.5 2 3 20 3-2-4. Mounting of seals 1) Rod seal, Cushion seal (Fig.9, ) Pay attention to the mounting direction of the seal.
Cylinder component Apply grease to the individual component, shown in the table 10. The following amount is needed per one 100 stroke cylinder. STROKE or 100mm and more Table 10. Grease apply amount 2 125 140 160 Portion to apply 100st 1517 2022 2426 50st Up 3 3 3 For grease, use lithium soap group grease JIS #2 3. Mounting seal 21 - .
f. g. h. i.() j. k. l. m. n. (IDF )(AF/AFF )(AFM/AM , -9- 4 4 4 4-2. 2. 2. 2. 4-2-1. D D 4-2-2.
Maximum operating pressure 1.0 MPa AV Regulating pressure range 0.05 to 0.7 MPa 5 to 60C (No freezing) Ambient and fluid temperature AU Filtration 5 m Compact design Recommended lubricant Turbine oil Class 1 (ISO VG32) AF Case Bowl guard provided as standard equipment AU100 has no bowl guard.
Maximum operating pressure 1.0 MPa AV Regulating pressure range 0.05 to 0.7 MPa 5 to 60C (No freezing) Ambient and fluid temperature AU Filtration 5 m Compact design Recommended lubricant Turbine oil Class 1 (ISO VG32) AF Case Bowl guard provided as standard equipment AU100 has no bowl guard.
-X465 0.1 to 1 Set pressure range (MPa) Desolution of setting and display (MPa) Power supply voltage Specifications AU 0.001 Class 10 With M5 fitting (Applicable tubing O.D. 6) Pressure switch Cleanliness Breather port 12 to 24 VDC 10%, Ripple (p-p) 10% or less (With reverse connection protection) 45 mA or less (but 70 mA or less at current output) AF IR1000/2000: With M5 fitting (Applicable
10 12 14 20 Note) M5 1 8 1 4 1 4 3 8 1 2 1 2 3 4 1 Note) Note) 3 Body ported 5 1 1 11 4 7 1 4 11 2 1 2 2 9 Note) Only bracket or foot may be mounted. 14-10-2 3 E-P HYREG Series VY1 Standard Specifications 02 03 04 04 06 10 02 03 04 VY1A0 0 1-M5 VY1B0 0 1M 0 5 1 VY110 0 10 0 1 2 VY120 0 10 0 1 2 VY130 0 1VY140 0 1VY150 0 1VY170 0 11 1 0 2 VY190 0 11 2 4 0 Model VY1D00-M5 10 M5 01 M5 Port
Thermo-chiller HRS offers convenient functions, self diagnosis and check display for easy maintenance.? An angled supply port facilitates the supply of circulating fluid, even when units are?stacked.? A?large digital display provides a clear view of the current and set values.? The dustproof filter is integrated with the grill of the front panel allowing mounting and removal of the HRS?filter
32A VEX9-32A VEX1-18-2A VEX1-18-2A F Foot (With bolt and washer) G27-10-R1-X207 G27-10-01 G36-10-01 G46-10-01 G Pressure gauge AN120-M5 N Silencer for breed port (PE) The optional parts are shipped in the same package.
Thermo-chiller HRS offers convenient functions, self diagnosis and check display for easy maintenance. An angled supply port facilitates the supply of circulating fluid, even when units are stacked. A large digital display provides a clear view of the current and set values. The dustproof filter is integrated with the grill of the front panel allowing mounting and removal of the HRS filter
Thermo-chiller HRS offers convenient functions, self diagnosis and check display for easy maintenance. An angled supply port facilitates the supply of circulating fluid, even when units are stacked. A large digital display provides a clear view of the current and set values. The dustproof filter is integrated with the grill of the front panel allowing mounting and removal of the HRS filter
0.8 0.7 0.7 0.7 0.6 0.6 0.6 0.5 0.5 0.5 0.4 0.4 0.4 0.3 0.3 0.3 0.2 0.2 0.2 0.1 0.1 0.1 VY130-5 VY140-5 VY150-5 0 1 2 3 4 5 0 1 2 3 4 5 0 1 2 3 4 5 V V V VY130-6 VY140-6 VY150-6 1 1 1 0 2.5 5 7.5 10 0 2.5 5 7.5 10 0 2.5 5 7.5 10 V V V VY130-7 VY140-7 VY150-7 mA mA mA 4 0 8 12 16 20 4 0 8 12 16 20 4 0 8 12 16 20 2 2 2 VY130-8 0 5 10 15 20 VY140-8 0 5 10 15 20 VY150-8 0 5 10 15 20 3 3 3 mA