Description Replacement parts Tubing outside diameter Metric sizes Inch sizes Body class Type LQ-GP J 3 03 03 4 04 04 04 04 6 06 06 06 8 08 10 10 10 12 12 12 19 19 19 25 25 1/8" 03 03 03 03 3/16" 05 05 1/4" 07 07 07 3/8" 11 11 1/2" 13 13 3/4" 19 19 1" 25 Insert pin holder assembly (with the parts case) Type Insert pin/ Holder type 1 2 1 2 3 4 5 6 J Insert pin material (J/K type
Contact P/A if an application under such conditions cannot be avoided. 10 One-touch fitting 10 One-touch fitting Parts list Material AFM20 Zinc die-cast AFM30, AFM40, AFM40-06 Aluminum die-cast Note Description No. Body 1 Platinum silver Replacement parts Part no. No.
Note 6) Product other than the option R is not equipped with an earth leakage breaker. Please purchase an appropriate earth leakage breaker separately.
Grinding fluid (Grinding machines) Fiber element Polypropylene 10 Grinding fluid (Oilstone) Fiber element Polypropylene 10 Lubricating oil Fiber element Polypropylene 50 Cooling water Fiber element Polypropylene 10 Cleaning water Fiber element Polypropylene 10 Developing fluid Fiber element Cotton 50 Lacquer Fiber element Cotton 10 Nitrogen gas Fiber element Cotton 10 Carbon dioxide Fiber
C D E F H RB I J K L M N OB Q RA W Y M4 x 0.7 4 14.5 7 5 M3 x 0.5 10 to 40 39.5 31.5 6 6 29 5.5 10 38 5 8 20 3.5 6.5 M6 x 1.0 7 18 10 5 M4 x 0.7 10 to 60 44 34 8 8 36 5.5 16 47 7 10 25.5 5.4 9 M6 x 1.0 7 19.5 10 6 M5 x 0.8 10 to 60 47.5 37.5 10 10 40 5.5 20 52 8 10 28 5.4 9 M6 x 1.0 7 23 10 49.5 7 M6 x 1.0 10 to 50, 75, 100 54 42 12 12 45 8.5 25 60 4.5 10 12 34 5.5 9 M6 x 1.0 7 26 10
, 3.2 kW, 4.2 kW, 5.1 kW, 5.9 kW (at 60Hz); Temperature range setting: 5 to 40°C; Temperature stability: ±0.1°C; Power supply requirement: single phase 200 to 230 VAC, 50/60Hz; Standards: CE, UL, RoHS; Circulating fluid: Tap water or 15% ethylene glycol, 30% Dowcal™100, ControXic 1642, Hexid A4, Coolflow IGE, NALCO®CCL105; SMC recommends Bypass Piping Set HRS-BP001 for Models HRS-012, HRS018
capacities: 1.3 kW, 1.7 kW (at 60Hz); Temperature range setting: 5 to 40°C; Temperature stability: ±0.1°C; Power supply requirement: single phase 100 VAC, 50/60Hz or 115 VAC, 60Hz; Standards: CE, UL, RoHS; Circulating fluid: Tap water or 15% ethylene glycol, 30% Dowcal™100, ControXic 1642, Hexid A4, Coolflow IGE, NALCO®CCL105; SMC recommends Bypass Piping Set HRS-BP001 for Models HRS-012, HRS018
, 3.2 kW, 4.2 kW, 5.1 kW, 5.9 kW (at 60Hz); Temperature range setting: 5 to 40°C; Temperature stability: ±0.1°C; Power supply requirement: single phase 200 to 230 VAC, 50/60Hz; Standards: CE, UL, RoHS; Circulating fluid: Tap water or 15% ethylene glycol, 30% Dowcal™100, ControXic 1642, Hexid A4, Coolflow IGE, NALCO®CCL105; SMC recommends Bypass Piping Set HRS-BP001 for Models HRS-012, HRS018
capacities: 1.3 kW, 1.7 kW (at 60Hz); Temperature range setting: 5 to 40°C; Temperature stability: ±0.1°C; Power supply requirement: single phase 100 VAC, 50/60Hz or 115 VAC, 60Hz; Standards: CE, UL, RoHS; Circulating fluid: Tap water or 15% ethylene glycol, 30% Dowcal™100, ControXic 1642, Hexid A4, Coolflow IGE, NALCO®CCL105; SMC recommends Bypass Piping Set HRS-BP001 for Models HRS-012, HRS018
Please contact us for the latest version.sales@ocaire.com, MAIN PC BOARD / HRS018-A-20, OTHERS, HRS THERMO-CHILLERS, 21, HRS - NO SIZE RATING, .00000 lb
Please contact us for the latest version.sales@ocaire.com, MAIN PC BOARD / HRS018-W-20-T, OTHERS, HRS THERMO-CHILLERS, 21, HRS - NO SIZE RATING, .00000 lb
Please contact us for the latest version.sales@ocaire.com, MAIN PC BOARD / HRS018-W-20-MT, OTHERS, HRS THERMO-CHILLERS, 21, HRS - NO SIZE RATING, .00000 lb
(mm) Stroke (mm) 20 40 50 30 +10.5 +12.5 +22.5 +24 10 to 16 +37.5 +40 +66.5 20 to 50 13-11-114 19 Series ZPR Vacuum Pad: Ball Joint Type Lateral Vacuum Entry with Buffer 20 25 32 ZPR F 10-0-A10 (With buffer) 10 13 16 J K J K ZPR F 10-0-A14 (With buffer) S S M10 x 1 M14 x 1 Hexagon width across flats 14 3 I Hexagon width across flats 19 3 5 Hexagon width across flats 10 J ZX Applicable tubing
i Conduit terminal j DIN connector a Model b d e f VEX5500 VEX5501 19 130 110 9 12 2.3 187 187.5 205.5 205 32 VEX5700 VEX5701 136 9 20 2.3 204 204.5 222.5 120 222 VEX VEX5900/5901 AN AMC 5.1-34 VEX5 Dimensions Select style VEX5510/E5511 VEX5710/E5711 Port size E F G H I J L M P A Model R T U B C K N O Q S D A,P port Rc(PT) , ,1 R port Rc(PT) VEX5510 VEX5511 1 2 3 4 , ,1 1 2 3 4 50 25 10
8 x L counter bore J J A + Stroke M M Rod end male thread CHKDB20, 25 CHKDB32 to 100 Water resistant type S N g C B + Stroke h + Stroke A + Stroke Rod end male thread (mm) B C D E F G H J K L M P Q R A Bore size (mm) 20 51 43 8 12 10 M8 x 1.25 10 6 30 5.5 9.5 depth 5.4 43 1/8 16.5 6 25 53 45 8 14 12 M10 x 1.5 12 6 36 5.5 9.5 depth 5.4 49 1/8 17 8 32 61 51 10 18 14 M12 x 1.75 15 7 47 6.6
Please check the specifications before use. 10. Do not use the product in an area where dust, powder dust, water, chemicals or oil is in the air. It will cause failure or malfunction. 11. Do not use the product in an area where a magnetic field is generated.
rt...i.i.1,.j,.: j..i riir',: .,,, I . .:t::;il..: li:aj;Ir:'ri.iii:r:l..::.::..l:lai,l.''.'''
Minimum lead wire bending radius 10 H thread effective depth C 4 x N through F Q I E M Z A + Stroke B + Stroke L W G M K J Standard [mm] Bore size Stroke range Without magnet for auto switch With magnet for auto switch C D E F G H I J K L M N P Q W Z A B A B 50 10 to 50 37 29 42.5 34.5 15 18 57 9 M10 x 1.5 74 6.5 16 8 46 5.5 1/8 13 63.5 15 63 10 to 50 41.5 33.5 46.5 38.5 15 18 70 10 M10
If it is forcefully disassembled, it could lead to damage. 1156 Floating Joint: Stainless Steel Type JS Series Construction 10, 16 20 to 63 J J Component Parts Component Parts No. Description Material Note No.
DA IB VA VB R H T ID U X PW IG DB 2-Rc 3/8 (plug) IF unlocking port Unlocks when pressurized 6H7 depth 10 2-Rc 3/8 PB GA GC 10 GB Q G IE J JA JB K PA + Stroke 6H7 depth 10 S FA FB C + Stroke B + Stroke A + Stroke E Note 1) Intermediate strokes other than standard strokes are manufactured by installing spacers.