Cooling Capacity: 200, Thread Type: N [NPT (w/Rc-NPT Conversion Fitting)], Power Supply: 46 [3-phase 380 to 415 VAC (50/60 Hz); 3-phase 460 to 480 VAC (60 Hz)], Option 1: w/Caster Adjuster-foot, UL Certification: UL Certification, Option 2: -
Cooling Capacity: 200, Thread Type: N [NPT (w/Rc-NPT Conversion Fitting)], Power Supply: 46 [3-phase 380 to 415 VAC (50/60 Hz); 3-phase 460 to 480 VAC (60 Hz)], Option 1: w/Fluid Fill Port, UL Certification: UL Certification, Option 2: -
Cooling Capacity: 200, Thread Type: N [NPT (w/Rc-NPT Conversion Fitting)], Power Supply: 46 [3-phase 380 to 415 VAC (50/60 Hz); 3-phase 460 to 480 VAC (60 Hz)], Option 1: w/Caster Adjuster-foot, UL Certification: UL Certification, Option 2: SI Unit Only
Cooling Capacity: 100, Thread Type: N [NPT (w/Rc-NPT Conversion Fitting)], Power Supply: 46 [3-phase 380 to 415 VAC (50/60 Hz); 3-phase 460 to 480 VAC (60 Hz)], Option 1: w/Fluid Fill Port, UL Certification: -, Option 2: -
Cooling Capacity: 150, Thread Type: N [NPT (w/Rc-NPT Conversion Fitting)], Power Supply: 46 [3-phase 380 to 415 VAC (50/60 Hz); 3-phase 460 to 480 VAC (60 Hz)], Option 1: w/Fluid Fill Port, UL Certification: -, Option 2: -
Cooling Capacity: 200, Thread Type: N [NPT (w/Rc-NPT Conversion Fitting)], Power Supply: 46 [3-phase 380 to 415 VAC (50/60 Hz); 3-phase 460 to 480 VAC (60 Hz)], Option 1: w/Fluid Fill Port, UL Certification: -, Option 2: -
Cooling Capacity: 100, Thread Type: N [NPT (w/Rc-NPT Conversion Fitting)], Power Supply: 46 [3-phase 380 to 415 VAC (50/60 Hz); 3-phase 460 to 480 VAC (60 Hz)], Option 1: A + K, UL Certification: -, Option 2: -
Cooling Capacity: 100, Thread Type: N [NPT (w/Rc-NPT Conversion Fitting)], Power Supply: 46 [3-phase 380 to 415 VAC (50/60 Hz); 3-phase 460 to 480 VAC (60 Hz)], Option 1: w/Caster Adjuster-foot, UL Certification: -, Option 2: -
Cooling Capacity: 150, Thread Type: N [NPT (w/Rc-NPT Conversion Fitting)], Power Supply: 46 [3-phase 380 to 415 VAC (50/60 Hz); 3-phase 460 to 480 VAC (60 Hz)], Option 1: A + K, UL Certification: -, Option 2: -
Cooling Capacity: 100, Thread Type: N [NPT (w/Rc-NPT Conversion Fitting)], Power Supply: 46 [3-phase 380 to 415 VAC (50/60 Hz); 3-phase 460 to 480 VAC (60 Hz)], Option 1: A + K, UL Certification: None, Option 2: SI Unit Only
Cooling Method: Air-cooled Refrigeration, Pipe Thread: N [NPT (w/Rc-NPT Conversion Fitting)], Power Supply: 46 [3-phase 380 to 415 VAC (50/60 Hz); 3-phase 460 to 480 VAC (60 Hz)], Option: Applicable to Deionized Water Piping
Cooling Method: Air-cooled Refrigeration, Pipe Thread: N [NPT (w/Rc-NPT Conversion Fitting)], Power Supply: 46 [3-phase 380 to 415 VAC (50/60 Hz); 3-phase 460 to 480 VAC (60 Hz)], Option: w/Automatic Fluid Fill Function
Cooling Method: Air-cooled Refrigeration, Pipe Thread: N [NPT (w/Rc-NPT Conversion Fitting)], Power Supply: 46 [3-phase 380 to 415 VAC (50/60 Hz); 3-phase 460 to 480 VAC (60 Hz)], Option: SI Unit Only
Be careful to the supply pressure and kinetic energy when performing an intermediate stop. Fine end stroke adjustment is considered as an intermediate stop, so the considerations for an intermediate stop must be observed when making any fine adjustments. When stopping the external slider in an intermediate position with an external stopper.
(Except C kit) F, P, T and S kits are provided with an exhaust on one side, while C kits are with an exhaust on both sides. The number of max. stations differs from kit to kit. (Refer to the table below.)
How to Order Type 46 (5 Port/Base mounted) Applicable solenoid valve SYJ340SYJ343SS5YJ3 46 05 M5 Type 46 Type S46 ( ) Single solenoid coil is on same side as the A, B port. M5 x 0.8 R1 R2 port Applicable blanking plate assembly SYJ3000-21-2A Stations Valve mounting direction 02 2 stations Single solenoid coil is on opposite side as the A, B port.
(33) 42 (35) 48 (35) 44 (37) 47 (34) 43 (36) ZPY40 49 (35) 50 (37) 49 (35) 44 (38) 46 (38) ZPY50 ( ): Figures for female thread connections.
Spatter cover Spatter cover Plug Prevention of tube releasing unconformity due to an inside intrusion or adhesion of the spatter. Prevention of tube releasing unconformity due to an inside intrusion or adhesion of the spatter. P. 5 KR P. 5 KRC1 KRP P. 5 Use to plug unused One-touch fittings.
46 LB 27 31 36 46 46 LA 35.5 41 47 62 62 LA 35 41 46 62 62 L 52.5 59 67 81 84 L 52.5 59 67 81 84 ZZ 115.5 127 137 171 175 Model MU25 MU32 MU40 MU50 MU63 Model MU25 MU32 MU40 MU50 MU63 Applicable pin 8 10 10 14 14 9 11 13 16 16 8 10 10 14 14 9 11 13 16 16 +0.058 0 +0.058 0 +0.058 0 +0.070 0 +0.070 0 0.2 0.4 0.2 0.4 0.2 0.4 0.2 0.4 0.2 0.4 +0.058 0 +0.058 0 +0.058 0 +0.070 0 +0.070 0 +0.2
46 LB 27 31 36 46 46 LA 35.5 41 47 62 62 LA 35 41 46 62 62 L 52.5 59 67 81 84 L 52.5 59 67 81 84 ZZ 115.5 127 137 171 175 Model MU25 MU32 MU40 MU50 MU63 Model MU25 MU32 MU40 MU50 MU63 Applicable pin 8 10 10 14 14 9 11 13 16 16 8 10 10 14 14 9 11 13 16 16 +0.058 0 +0.058 0 +0.058 0 +0.070 0 +0.070 0 0.2 0.4 0.2 0.4 0.2 0.4 0.2 0.4 0.2 0.4 +0.058 0 +0.058 0 +0.058 0 +0.070 0 +0.070 0 +0.2