W W D E d M a MA Q C A K F NA NB B H S + Stroke M ZZ + Stroke With rod boot e 10 l f h + l ZZ + l + Stroke (mm) Bore size (mm) A a B C D d F G GA GB J K M MA MM NA NB P Q R S T V W E 0 -0.018 0 -0.021 0 -0.021 0 -0.021 0 -0.025 0 -0.025 0 -0.025 0 -0.062 0 -0.062 0 -0.074 0 -0.074 0 -0.074 0 -0.074 0 -0.087 40 17 23 10 60 44 18 25 14 17.5 9.5 M8 x 1.25 18 13 20 M14 x 1.5 30 22 1/4 5 37 106
CM2 H L 40 F A J 150 Standard DM2 C H L 40 F A J C73 150 With auto switch Rod boot Without rod boot Nylon tarpaulin Heat resistant tarpaulin Bore size 20mm 25mm 32mm 40mm Air cylinder with auto switch 20 25 32 40 Number of auto switches S n J K 2 1 n Applicable Auto Switches/Refer to p.5.3-2 for further information on auto switches.
With bracket a Option w Note) Applicable to 90-AF40-06, 90-AFM40-06 and 90-AFD-40-06.
Option Note 1) Symbol Nil B H Applicable model AR20(K) to 60(K) AR20(K) to 40(K) Description With bracket With set nut (for panel mount) Note 1) Optional parts are not assembled and are supplied loose at the time of shipment. 42 Regulator: Modular Type with Back flow Mechanism AR20K to 60K How to Order Regulator with a built-in mechanism that ensures a quick release of the outlet air pressure
) Model D A 34 40 50 B 11 14.5 20.5 ZP3B-Y2B3-B5 ZP3B-Y2B6-B5 ZP3B-Y2B10-B5 16.5 19 23 8 Lateral 8 Note) The symbol "" indicates buffer type "J" or "K".
ASN AQ ASV AK ASS ASR ASF 15-15-5 1 Air Saving Valve Pressure Valve Flow Valve Series ASR/Series ASQ Air consumption reduction ratio (%) 40 Working stroke pressure (MPa) 40% reduction in air consumption 40% reduction in air consumption 30 0.9 0.7 20 0.5 10 0.3 Cuts air consumption by operating the return stroke at a reduced pressure.
19 10 17.5 (9) 17.5 M8 x 1.0 View A 6 7.5 68 8.5 7.5 21.5 85 + Stroke 40 Sine Rodless Cylinder Slider Type/Ball Bushing Series REAL Max.
Model selected 10-2-8 8 Series REA Model Selection 2 Caution on Design 1 Selection Method A): Distance from Cylinder Shaft Center Allowable Driving Capacity> RE A B 25 40 32 500 500 REC 200 300 400 300 200 300 200 Recommended driving force Fn (N) Recommended driving force Fn (N) CX Recommended driving force Fn (N) 100 100 100 CY 50 40 20 30 40 50 20 30 40 50 20 30 MQQ M Usable range
Model selected 10-2-8 8 Series REA Model Selection 2 Caution on Design 1 Selection Method A): Distance from Cylinder Shaft Center Allowable Driving Capacity> RE A B 25 40 32 500 500 REC 200 300 400 300 200 300 200 Recommended driving force Fn (N) Recommended driving force Fn (N) CX Recommended driving force Fn (N) 100 100 100 CY 50 40 20 30 40 50 20 30 40 50 20 30 MQQ M Courtesy of
B 10.5 10.5 5.1 5.1 9.5 24 1 A B NN x M6 x 1 thread depth 12 6 HA 5H9 ( ) depth 5 +0.030 0 5H9 ( ) depth 5 +0.030 0 GA A-A B-B (mm) Model F 38 38 48 58 40 46 44 44 N 4 4 4 4 6 6 8 10 G 18 18 19 19 21 36 17 H 39 39 48 58 52 44 44 NN 2 2 2 2 3 3 4 5 GA 18 18 19 19 48 73 80 105 HA 39 39 48 58 45 52 88 88 I 12 12 12 12 20 15 18 23 J 40 40 50 60 68 105 145 165 K 28 38 48 58 68 93 118 143 KA
HRS 100/150 HRS 100/150 Applicable model Dimension [mm] A B C HRS100/150-A-20/40-A 830 302 1552 HRS100/150-W-20/40-A 570 401 1353 C HRSH 090 HRSH 118 HRSE A B Option symbol With Earth Leakage Breaker B HRZ HRZD HRS 20 B With earth leakage breaker HRW A leakage breaker is built in to automatically stop the supply power when it has short-circuit, over current or electrical leakage.
Use a single knuckle joint or a double knuckle joint individually.
95.5 110.5 121.5 136.5 12 12 12 11.5 11.5 B A MY1C (Cam follower guide type) 63 50 40 32 25 Mounting position A 97.5 127.5 157.5 278.5 323.5 B Operating range l Note) 122.5 152.5 182.5 121.5 136.5 12 12 12 11.5 11.5 B A MY1H (High precision guide type) 40 32 25 Mounting position A 180 216 131.5 B 100 124 88.5 Operating range l Note) 11.5 11.5 8.5 B A MY1HT (High rigidity/High precision
1.0 Communication speed [bps] 156 k/625 k/2.5 M /5 M/10 M 125 k/250 k/500 k 9.6 k/19.2 k/45.45 k/ 93.75 k/187.5 k/500 k/ 1.5 M/3 M/6 M/12 M 10 M/100 M Configuration file Note 2) EDS file GSD file EDS file Communication specifications Input 896 points 108 words 4 stations occupied (8 times setting) Input 200 bytes Output 200 bytes Input 57 words Output 57 words Input 256 bytes Output 256
Applicable model Dimension in [mm] A B C HRS100/150-A-20/40-A 32.7 [830] 11.9 [302] 61.1 [1552] HRS100/150-W-20/40-A 22.4 [570] 15.8 [401] 53.5 [1353] C 118 A B Option symbol With Earth Leakage Breaker B HRS 20 B With earth leakage breaker A leakage breaker is built in to automatically stop the supply power when it has short-circuit, over current or electrical leakage.
Description Symbol A B C D E Description For piping 12 x 9 40 swivel elbow For piping 10 x 8 40 swivel elbow For piping 10 x 7.5 40 swivel elbow For piping 8 x 6 40 swivel elbow For piping 6 x 4 40 swivel elbow Part no. VCKK1209-02F VCKK1008-02F VCKK1075-02F VCKK0806-02F VCKK0604-02F Symbol F G H J K Part no.
Contents 30 Damper B 20 Urethane CG1N20-PS 40 is the same as damper A 31 Snap ring 25 Stainless steel CG1N25-PS 32 A set of above Nos. Wear ring 32 Resin CG1N32-PS 33 37, 39, 40 Rod end nut 40 Rolled steel CG1N40-PS Nickel plated 34 BC element Bronze 35 Since the lock section for Series CNG is normally replaced as a unit, replacement seal kits are for the cylinder section only.
R K05 Omron D2VW-5, 3 A 250 V AC, 0.4 A 125 V DC, 5 A 30 V DC. Temperature range: -40 to +85 C / -40 to +185 F. Not applicable to 6. sign "X", "X7", "Z", "U" and "E4". Omron D2VW-01, gold plated contacts, 100 mA 30 V DC / 125 V AC. Temperature range: -40 to +85 C / -40 to +185 F. Not applicable to 6. sign "X", "X7", "Z", "U" and "E4".
IDFA 100F 40 For use in Europe Nil C G K R V Size Size 100F 125F 150F Option Voltage Symbol Note) Description Symbol Voltage Nil C G K R V None Three-phase 400 VAC (50 Hz) 40 Anti-corrosive treatment for copper tube With Chinese labels and a Chinese operation manual Moderate pressure specification (1.6 MPa) With a circuit breaker With a timer controlled solenoid valve type auto drain Note
Contents 30 Damper B 20 Urethane CG1N20-PS 40 is the same as damper A 31 Snap ring 25 Stainless steel CG1N25-PS 32 A set of above Nos. Wear ring 32 Resin CG1N32-PS 33 37, 39, 40 Rod end nut 40 Rolled steel CG1N40-PS Nickel plated 34 BC element Bronze 35 Since the lock section for Series CNG is normally replaced as a unit, replacement seal kits are for the cylinder section only.