Piping Specifications: NPT1/8 Piping Adapter, Side Ported, Output Specifications: PNP Open Collector 2 Outputs, Unit Specifications: Unit Switching Function, Initial Value psi, Not Allowed for Use in Japan, Lead Wire: G [Lead Wire w/Connector (2m Lead Wire Length)+Connector Cover], Adapter: None, Calibration Certification: w/Certificate
Piping Specifications: NPT1/8 Piping Adapter, Side Ported, Output Specifications: PNP Open Collector 1 Output+Analog Voltage, Unit Specifications: Unit Switching Function, Initial Value psi, Not Allowed for Use in Japan, Lead Wire: G [Lead Wire w/Connector (2m Lead Wire Length)+Connector Cover], Adapter: None, Calibration Certification: w/Certificate
Piping Specifications: NPT1/8 Piping Adapter, Side Ported, Output Specifications: PNP Open Collector 2 Outputs, Unit Specifications: Fixed SI Unit, kPa, Lead Wire: -, Adapter: -, Calibration Certification: -
Piping Specifications: NPT1/8 Piping Adapter, Side Ported, Output Specifications: NPN Open Collector 2 Outputs, Unit Specifications: Fixed SI Unit, kPa, Lead Wire: G [Lead Wire w/Connector (2m Lead Wire Length)+Connector Cover], Adapter: None, Calibration Certification: w/Certificate
C I R C U I T ZSM1-115 H O W T O O R D E R V A C U U M S W I T C H S E R I E S ZSM1 ZSM1-121 ZSM1 ACCESSORIES CONTACT PROTECTION BOX ACCESSORIES V A C U U M S W I T C H S E R I E S ZSE1 C O N N E C T I O N Diaphragm type switches have no built-in contact protection circuit.
E S W I T C H: S E R I E S IS1000 S W I T C H CHARACTERISTICS E L E C T R I C A L C I R C U I T Up to 100V AC/DC Max Contact Capacity IS1000 01 2V (AC), 2W (DC) Voltage 24V AC, DC or less 48V AC, DC 100V AC, DC P O R T T H R E A D Max Operating Current 50mA 40mA 20mA 01 1/8 PT N01 NPT1/8 Shock Resistance 30G Response Time 1.2ms Set Pressure Range Lead Wire Length *Note.
ZP Flow characteristics C (dm3/(sbar)) Effective area (mm2) (Cv) Port size Rc Model Orifice dia.
All data given in a technical specification sheet is based on 25[C]. The temperature range is dependent on the product series. Normally SMC products are rated from 0 to 50[C] or 0 to 60[C]. The failure predict function allows the user to anticipate possible maintenance requirements. How does it work?
C Drain cock Drain guide (A) (B) Rc , NPT, G Mounting bracket Port size Model C B A Drain piping F G H J K L B' D E 6 6 1/4 female thread M3 x 0.5 1 4 2.3 15 12 20 50 73 AMC220 40 56 88 100 22 Depth 8 Body size A B C M3 x 0.5 71 88 101 101 121 55 63 83 96 96 116 1 4 3 8 , 56 75 102 118 135 153 AMC320 75 120.5 140.5 2.3 15 20 30 50 123.5 24 55 2 3 5 6 8 9 Depth 8 M4 x 0.7 1 2 3 4 AMC520
Piping Specifications: M5 (M5 Female Thread/Side Piping Port), Output Specifications: C (NPN Open Collector 1 Output+Analog Voltage), Unit Specifications: Unit Switching Function (Not Allowed for Use in Japan), Lead Wire: G [Lead Wire w/Connector (2m Lead Wire Length)+Connector Cover]
Piping Specifications: M5 (M5 Female Thread/Side Piping Port), Output Specifications: C (NPN Open Collector 1 Output+Analog Voltage), Unit Specifications: Unit Switching Function (Not Allowed for Use in Japan), Lead Wire: G [Lead Wire w/Connector (2m Lead Wire Length)+Connector Cover], Adapter: D (Panel Mount Adapter+Front Protective Cover)
Piping Specifications: M5 (M5 Female Thread/Side Piping Port), Output Specifications: C (NPN Open Collector 1 Output+Analog Voltage), Unit Specifications: Unit Switching Function (Not Allowed for Use in Japan), Lead Wire: G [Lead Wire w/Connector (2m Lead Wire Length)+Connector Cover], Adapter: R [DIN Rail Adapter (DIN Rail to be Prepared by Customer)]
Piping Specifications: M5 (M5 Female Thread/Side Piping Port), Output Specifications: C (NPN Open Collector 1 Output+Analog Voltage), Unit Specifications: Unit Switching Function (Not Allowed for Use in Japan), Lead Wire: No Lead Wire, Adapter: R [DIN Rail Adapter (DIN Rail to be Prepared by Customer)]
Piping Specifications: M5R (M5 Female Thread/Rear Piping Port), Output Specifications: C (NPN Open Collector 1 Output+Analog Voltage), Unit Specifications: Unit Switching Function (Not Allowed for Use in Japan), Lead Wire: G [Lead Wire w/Connector (2m Lead Wire Length)+Connector Cover], Adapter: D (Panel Mount Adapter+Front Protective Cover)
Piping Specifications: M5 (M5 Female Thread/Side Piping Port), Output Specifications: C (NPN Open Collector 1 Output+Analog Voltage), Unit Specifications: Unit Switching Function (Not Allowed for Use in Japan), Lead Wire: G [Lead Wire w/Connector (2m Lead Wire Length)+Connector Cover], Adapter: R [DIN Rail Adapter (DIN Rail to be Prepared by Customer)], Calibration Certification: K (w/Certificate
Piping Specifications: M5R (M5 Female Thread/Rear Piping Port), Output Specifications: C (NPN Open Collector 1 Output+Analog Voltage), Unit Specifications: P (Unit Switching Function, Initial Value psi, Not Allowed for Use in Japan), Lead Wire: G [Lead Wire w/Connector (2m Lead Wire Length)+Connector Cover], Adapter: D (Panel Mount Adapter+Front Protective Cover)
Piping Specifications: M5 (M5 Female Thread/Side Piping Port), Output Specifications: C (NPN Open Collector 1 Output+Analog Voltage), Unit Specifications: P (Unit Switching Function, Initial Value psi, Not Allowed for Use in Japan), Lead Wire: G [Lead Wire w/Connector (2m Lead Wire Length)+Connector Cover], Adapter: R [DIN Rail Adapter (DIN Rail to be Prepared by Customer)]