Pressure Range: 0 to 1.6 MPa, Piping: NPT 1/4, Output Specification: I/O Link: Switch Output 1 + Switch Output 2 [Switch Output: NPN or PNP Switching Type], Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: Lead Wire with M12 Connector; Right-angled, 5 m, Bracket: Bracket A, Interchangeable with ISE70, Operation Manual/Calibration
Pressure Range: 0 to 1.6 MPa, Piping: NPT 1/4, Output Specification: I/O Link: Switch Output 1 + Switch Output 2 [Switch Output: NPN or PNP Switching Type], Unit Specification: SI Unit Only, Lead Wire: Lead Wire with M12 Connector; Straight, 5 m, Bracket: Bracket A, Interchangeable with ISE70, Operation Manual/Calibration Certificate: Operation Manual + Calibration Certificate
Pressure Range: 0 to 1.6 MPa, Piping: NPT 1/4, Output Specification: I/O Link: Switch Output 1 + Switch Output 2 [Switch Output: NPN or PNP Switching Type], Unit Specification: SI Unit Only, Lead Wire: Lead Wire with M12 Connector; Right-angled, 5 m, Bracket: Bracket A, Interchangeable with ISE70, Operation Manual/Calibration Certificate: Operation Manual + Calibration Certificate
Pressure Range: 0 to 1.6 MPa, Piping: NPT 1/4, Output Specification: I/O Link: Switch Output 1 + Switch Output 2 [Switch Output: NPN or PNP Switching Type], Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: Lead Wire with M12 Connector; Straight, 5 m, Bracket: Bracket A, Interchangeable with ISE70, Operation Manual/Calibration
Pressure Range: 0 to 1.6 MPa, Piping: NPT 1/4, Output Specification: I/O Link: Switch Output 1 + Switch Output 2 [Switch Output: NPN or PNP Switching Type], Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: None, Bracket: Bracket A, Interchangeable with ISE70, Operation Manual/Calibration Certificate: -
Pressure Range: 0 to 1.6 MPa, Piping: NPT 1/4, Output Specification: I/O Link: Switch Output 1 + Switch Output 2 [Switch Output: NPN or PNP Switching Type], Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: Lead Wire with M12 Connector; Straight, 5 m, Bracket: Bracket A, Interchangeable with ISE70, Operation Manual/Calibration
Pressure Range: 0 to 1 MPa, Piping: NPT 1/4, Output Specification: Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type], Unit Specification: -, Lead Wire: -, Bracket: -, Operation Manual/Calibration Certificate: -
The maximum detectable piston speed is: Auto switch operating range (mm) _ Time load applied (ms) Operating current of load (OFF condition) > Leakage current V(mm/s) = x 1000 If the criteria given in the above formula are not met, it will not reset correctly (stays ON). Use a 3 wire switch if this specification will not be satisfied.
Time load applied (ms) 2) If the internal resistance of a light emitting diode causes a problem, select a switch without an indicator light (Model D-C80). 4. Wiring should be kept as short as possible.
The maximum detectable piston speed is: Auto switch operating range (mm) _ Load operating time (ms) Operating current of load (OFF condition) > Leakage current V (mm/s) = x 1000 If the criteria given in the above formula are not met, it will not reset correctly (stays ON). Use a 3 wire switch if this specification will not be satisfied.
Tube cover Cylinder tube gasket 31 SMC'S GLOBAL MANUFACTURING, DISTRIBUTION AND SERVICE NETWORK EUROPE SWEDEN SMC Pneumatics Sweden AB SWITZERLAND SMC Pneumatik AG. UK SMC Pneumatics (U.K.) Ltd. EUROPE AUSTRIA SMC Pneumatik GmbH. CZECH SMC Czech s.r.o. DENMARK SMC Pneumatik A/S FINLAND SMC Pneumatiikka OY FRANCE SMC Pneumatique SA GERMANY SMC Pneumatik GmbH HUNGARY SMC Hungary Kft.
The maximum detectable piston speed is: Operating current of load (OFF condition) > Leakage current Auto switch operating range (mm) _ Time load applied (ms) V (mm/s) = x 1000 If the criteria given in the above formula are not met, it will not reset correctly (stays ON). Use a 3 wire switch if this specification will not be satisfied.
Auto switch operating range (mm) _ Load operating time (ms) V(mm/s) = x 1000 4. Keep wiring as short as possible.
Auto switch operating range (mm) Load operating time (ms) x 1000 V (mm/s) = 4. Keep wiring as short as possible.
Auto switch operating range (mm) Load operating time (ms) V(mm/s) = x 1000 4. Keep wiring as short as possible.
Auto switch operating range (mm) Load operating time (ms) x 1000 V (mm/s) = Current to operate load (OFF condition) > Leakage current 4. Keep wiring as short as possible.
GERMANY SMC Pneumatik GmbH ITALY SMC ltalia SpA FRANCE SMC Pneumatique SA HOLLAND SMC Controls Bv SWEDEN SMC Pneumatics Sweden AB SWITZERLAND SMC Pneumatik AG AUSTRIA SMC Pneumatik GmbH SPAIN SMC Espafra, S.A. IRETAND SMC Pneumatics (lreland) Ltd. Asia JAPAN Oceania AUSTRALIA SMC Pneumatics (Australia) Pty. Ltd. NEW ZEALAND SMC Pneumatics (N.2.) Ltd.
The maximum detectable piston speed is: Operating current of load (OFF condition) > Leakage current Auto switch operating range (mm) _ Time load applied (ms) V(mm/s) = x 1000 If the criteria given in the above formula are not met, it will not reset correctly (stays ON). Use a 3 wire switch if this specification will not be satisfied.
The maximum detectable piston speed is: Operating current of load (OFF condition) > Leakage current Auto switch operating range (mm) _ Load operating time (ms) V(mm/s) = x 1000 If the criteria given in the above formula are not met, it will not reset correctly (stays ON). Use a 3-wire switch if this specification will not be satisfied.
Auto switch operating range (mm) Load operating time (ms) x 1000 V (mm/s) = Operating current of load (OFF condition) > Leakage current In case of a high piston speed, it is possible to extend the operating time of the load by using an auto switch (D-F5NT, DF7NT, and D-G5NT) with a built-in off delay timer (approx. 200ms). 4. Keep wiring as short as possible.