A cabtire cable with an O.D. 6 to 12 mm is applicable. Tighten each part with an appropriate tightening torque shown below.
PD Mounting 20 12 12 13 24.2 6 25 12 10 (12) 13 26.7 6 32 12 10 (12) 13 30.2 6 40 12 10 (12) 16 34.6 8 50 13 13 20 40.6 10 63 13 13 20 47.1 10 HH Applicable Tubing O.D./I.D. Note) ( ): Long stroke Bore size (mm) 20 25 32 40 50 63 Applicable tubing O.D. (mm) 6/4 6/4 6/4 8/6 10/7.5 10/7.5 Applicable tubing material Can be used for either nylon, soft nylon or polyurethane tubing.
6 !5 12-2 12-1 7-2 7-1 1-2 1-1 1-1 Width across flats Rod view 32 (2:1) Component Parts No.
X Port size) Speed controller System figure System Solenoid valve SYJ7l40-01 Rc(PT)1/8 (S = 12.6mm2) AN110-01 (S = 35mm2) 4 X 1/8 AS2301F-01-04 A 02 03 AS3301F-06 6 X 1/4 B q 02 03 AS3301F-08 SYJ7l40-02 Rc(PT)1/4 (S = 12.6mm2) 8 X 1/4 C AN200-02 (S = 35mm2) 02 03 AS3301F-10 10 X 1/4 D 12 X 1/4 12 X 1/2 AS4001F-12 w E 1.2-53 Series SYJ7000 How to Order Light and surge voltage suppressor
VMG1-06-150-300 VMG1-06-200-300 VMG1-06-150-600 VMG1-06-200-600 VMG1-06-150-100 VMG1-06-200-100 VMG1-06-150-150 VMG1-06-200-150 VMG1-08-250-100 VMG1-08-300-100 VMG1-08-350-100 VMG1-08-250-150 VMG1-08-300-150 VMG1-08-350-150 VMG1-08-250-300 VMG1-08-300-300 VMG1-08-350-300 VMG1-08-250-600 VMG1-08-300-600 VMG1-08-350-600 Nozzle size Nozzle length 1.5 2 1.5 2 1.5 2 1.5 2 2.5 3 3.5 2.5 3 3.5 2.5
6 6 FB 4 Shield ground SHIELD 9 Optical fiber (reserve) RTS 12 PS Pin no. 3, 5, 7, 8, 10 and 11 marked with "" are open.
{.000 3,200,000 7,S00 l 6 JO 1,500 lr.6 0tltllyrx5 l.t3 6 tz-t4a 36,000 3,730,000 7,800 20 64 1,500 r4.5 All d mensions in inches. ({t.log llo. (llodel) (rtolog llo. tltlodcll A AI B t) lt t t( l(l wt wt (tR)0IlS%xl 5.68 6.38 lY4-12 Ult .50 I.50 1.7 5 3.63 0.91 0.8? ?.
Vmax (mm/s) 2000 10 32 1/4 1/4 2500 3000 12.5 15 30 6 10 1/4, 3/8 = 0.7 500 4 20 0.5 0.1 0.3 10 10 1/4, 3/8 32 1000 8 1/4, 3/8 3/8 3/8 3/8 1500 2000 2500 3000 12 16 20 24 0 1,000 2,000 3,000 Maximum speed Vmax (mm/s) 40 8 10 1/4, 3/8 500 6 40 = 0.7 30 40 3/8, 12 3/8, 12 3/8, 12 3/8, 12 3/8, 12 1000 1500 2000 2500 3000 12 18 24 30 36 0.5 0.1 0.3 20 10 Note) Refer to page 10-6-7 for maximum
ZR IN side, OUT side (/min (ANR)) Weight (g) Model ZM ZFC100-04 4 10 11.5 ZFC100-06 6 20 ZH Metric size ZFC200-06 6 30 21.5 ZU ZFC200-08 8 50 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com ZFC101-03 5/32" 10 11.5 ZL ZFC101-07 1/4" 20 Inch size ZFC201-07 1/4" 30 ZY
Rated voltage 5 6 24 VDC 12 VDC Note 1) Light/surge voltage suppressor is built-in.
Also note that a 12 VDC relay is not applicable. 6. Use caution to the leakage current.
ISA-2-7 ISAl-1 ISAl-2/ISAl-1 ISAl-3/ISAl-2 ISAl-4/ISAl-3 ISAl-5/ISAl-4 ISAl-6/ISAl-5 ISAl-6 No.
3M Limited SOL.A SOL.B SOL.A SOL.B SOL.A SOL.B SOL.A SOL.B (+) () () (+) 11 11 6 stations 6 stations Fujitsu Limited (+) () () (+) 12 12 Japan Aviation Electronics Industry, Ltd. (+) () () (+) 13 13 7 stations 7 stations (+) () () (+) 14 14 J.S.T.
800 19.5 M10 x 1.25 22 17 32 12 16 12 8 46 6 8 32 5.5 7 28 121 5.5 40 55 13 28 19 15 32 Up to 800 21 M14 x 1.5 24 22 38 16 19 12 8 53 8 9 40 7.5 7 30 133 6 45 60 13 36 19 15 40 Up to 800 21 M16 x 1.5 24 24 41 18 21 14 11 54 10 11 48 7.5 9 35 158 6 55 75 19 44 24 21 (mm) Foot bracket plate thickness is dimension LT + 1 mm.
7.5 0.5 1 30 30 35 35 40 40 52 62 (14.5) (11.5) 126 (134) 133 (141) 135 (143) 150 (159) 170 (182) 170 (182) 191 (205) 191 (205) Bore (mm) 8 10 12 14 16 18 Bore (mm) ZZ GB S HH GA PD HD (17.5) (11.5) 20 25 32 40 50 63 20 25 32 40 50 63 70 70 72 80 95 95 (19.5) (11.5) 1 12 12 12 12 13 13 10 (12) 24.2 6 6 6 8 10 10 107 13 13 13 16 20 20 0.25 stroke (22.5) 1.25 2 3 10 (12) 26.7 112 (13) 10
67.1 8 12 5 M14 x 1.5 19 6 12 92.6 13.5 21.9 15 88.2 73.2 10 17 6 M20 x 1.5 27 6 18 105.2 17 31.2 25 124 99 12 24 8 M27 x 1.5 36 6 25 147 23 41.6 The dimensions of H/L type are the same.
One-touch fitting for 4 C4 SY3000 2 position double One-touch fitting for 6 C6 One-touch fitting for 4 C4 2 One-touch fitting for 6 C6 For DC SY5000 One-touch fitting for 8 C8 5 24 VDC 6 12 VDC SY9000 has no bracket.
Flow Direction Symbols on Body Flow Rate and Effective Area Meter-out type Meter-in type AS221F-01 AS231F-01 AS221F-02 AS231F-02 AS321F AS331F AS421F AS431F AS121F AS131F Model Symbol JIS Symbol Metric size 3.2, 4, 6 3.2, 4 6, 8, 10 8, 10 4 6 6 8 10 12 10, 12 Tubing O.D. 1/8", 5/32" 1/8" 3/16", 1/4" 1/4", 5/16" 3/8" 1/4" Inch size 5/32" 3/16" 5/16" 3/8" 1/2" 5/32" 5/16" 3/8" 3/16", 1/4" Controlled
For DIN rail model number, refer to page 4-12-12.