Cooling Capacity: 018 (Cooling Capacity: 1700/1900W, 50/60 Hz), Cooling Method: W (Water-cooled Refrigeration), Thread: Rc, Option: BM (B + M)
Cooling Capacity: 018 (Cooling Capacity: 1700/1900W, 50/60 Hz), Cooling Method: W (Water-cooled Refrigeration), Thread: Rc, Option: BMT (B + M + T)
Cooling Capacity: 018 (Cooling Capacity: 1700/1900W, 50/60 Hz), Cooling Method: W (Water-cooled Refrigeration), Thread: Rc, Option: MT (M + T)
Cooling Capacity: 018 (Cooling Capacity: 1700/1900W, 50/60 Hz), Cooling Method: W (Water-cooled Refrigeration), Thread: F (G w/PT-G Conversion Fitting Set)
Cooling Capacity: 018 (Cooling Capacity: 1700/1900W, 50/60 Hz), Cooling Method: A (Air-cooled Refrigeration), Thread: F (G w/PT-G Conversion Fitting Set), Option: MT (M + T)
Cooling Capacity: 018 (Cooling Capacity: 1700/1900W, 50/60 Hz), Cooling Method: A (Air-cooled Refrigeration), Thread: Rc, Option: J (Automatic Water Supply Function)
Cooling Capacity: 018 (Cooling Capacity: 1700/1900W, 50/60 Hz), Cooling Method: A (Air-cooled Refrigeration), Thread: Rc, Option: BJ (B + J)
Cooling Capacity: 018 (Cooling Capacity: 1700/1900W, 50/60 Hz), Cooling Method: W (Water-cooled Refrigeration), Thread: F (G w/PT-G Conversion Fitting Set), Option: BT (B + T)
Cooling Capacity: 018 (Cooling Capacity: 1700/1900W, 50/60 Hz), Cooling Method: W (Water-cooled Refrigeration), Thread: F (G w/PT-G Conversion Fitting Set), Option: M [Applicable to DI Water (Deionized Water) Piping]
Fluid: air and inert gas, Operating pressure: 0.1MPa to 1.0MPa, Effective area (Cv): 2.2 to 5.7, Coil rated voltage: 100, 200 VAC 50/60Hz; 24VDC, Response time: 60 or less ms, Ambient/fluid temp: -10 to +60°C, 5 port pilot operated valve, 4/5 PORT SOLENOID VALVE, I50, 1700 lb
Fluid: air and inert gas, Operating pressure: 0.1MPa to 1.0MPa, Effective area (Cv): 2.2 to 5.7, Coil rated voltage: 100, 200 VAC 50/60Hz; 24VDC, Response time: 60 or less ms, Ambient/fluid temp: -10 to +60°C, 5 port pilot operated valve, 4/5 PORT SOLENOID VALVE, I50, 1700 lb
Fluid: air and inert gas, Operating pressure: 0.1MPa to 1.0MPa, Effective area (Cv): 2.2 to 5.7, Coil rated voltage: 100, 200 VAC 50/60Hz; 24VDC, Response time: 60 or less ms, Ambient/fluid temp: -10 to +60°C, 5 port pilot operated valve, 4/5 PORT SOLENOID VALVE, I50, 1700 lb
Fluid: air and inert gas, Operating pressure: 0.1MPa to 1.0MPa, Effective area (Cv): 2.2 to 5.7, Coil rated voltage: 100, 200 VAC 50/60Hz; 24VDC, Response time: 60 or less ms, Ambient/fluid temp: -10 to +60°C, 5 port pilot operated valve, 4/5 PORT SOLENOID VALVE, I50, 1700 lb
Fluid: air and inert gas, Operating pressure: 0.1MPa to 1.0MPa, Effective area (Cv): 2.2 to 5.7, Coil rated voltage: 100, 200 VAC 50/60Hz; 24VDC, Response time: 60 or less ms, Ambient/fluid temp: -10 to +60°C, 5 port pilot operated valve, 4/5 PORT SOLENOID VALVE, I50, 1700 lb
Fluid: air and inert gas, Operating pressure: 0.1MPa to 1.0MPa, Effective area (Cv): 2.2 to 5.7, Coil rated voltage: 100, 200 VAC 50/60Hz; 24VDC, Response time: 60 or less ms, Ambient/fluid temp: -10 to +60°C, 5 port pilot operated valve, 4/5 PORT SOLENOID VALVE, I50, 1700 lb
Fluid: air and inert gas, Operating pressure: 0.1MPa to 1.0MPa, Effective area (Cv): 2.2 to 5.7, Coil rated voltage: 100, 200 VAC 50/60Hz; 24VDC, Response time: 60 or less ms, Ambient/fluid temp: -10 to +60°C, 5 port pilot operated valve, 4/5 PORT SOLENOID VALVE, I50, 1700 lb
Fluid: air and inert gas, Operating pressure: 0.1MPa to 1.0MPa, Effective area (Cv): 2.2 to 5.7, Coil rated voltage: 100, 200 VAC 50/60Hz; 24VDC, Response time: 60 or less ms, Ambient/fluid temp: -10 to +60°C, 5 port pilot operated valve, 4/5 PORT SOLENOID VALVE, I50, 1700 lb
Fluid: air and inert gas, Operating pressure: 0.1MPa to 1.0MPa, Effective area (Cv): 2.2 to 5.7, Coil rated voltage: 100, 200 VAC 50/60Hz; 24VDC, Response time: 60 or less ms, Ambient/fluid temp: -10 to +60°C, 5 port pilot operated valve, 4/5 PORT SOLENOID VALVE, I50, 1700 lb
rotating eccentric angle 2 3 Installation Requirement for Swing Impacts (mm) Model Load on mounting frame 2 (Allowable rotating angle) With cap Basic type R (Min. installation radius) Model S (Stroke) RJ0604 RJ0805 RJ0806 RJ1006 RJ1007 RJ1410 RJ1412 RJ2015 RJ2725 450 N 380 N RJ0604 RJ0805 RJ0806 RJ1006 RJ1007 RJ1410 RJ1412 RJ2015 RJ2725 76 4 630 N 258 96 5 900 N 277 115 6 1600 N 306 115 6 1700
and 1/2 HP, 125 or 250 VAC. 1.2 Amp, 125 VDC; 1/4 Amp, 250 VDC 5 Amps, 120 VAC "L" (lamp load) 10A 10 Amps and 1/4 HP, 125 or 250 VAC. 1/2 Amp, 125 VDC; 1/4 Amp, 250 VDC 3 Amps, 125 VAC "L" (lamp load) 4A 4 Amps, 250 VAC 1/10 HP, 125 VAC 3A 3 Amps, 125, 250, 277 VAC 1/10 HP, 250 VAC Gold Option .1 Amp, 125 VAC MATERIAL APPROVALS Components listed as polysulfone are made of Amoco UDEL P-1700