SMC Corporation of America
Elite Part Number Search
Search Results "NCDQ2KB50-75DZ-A90"

D-A90 cannot be mounted on Series MY1HT. Electrical entry (Fetching direction) Type Model Features D-A90 D-Z80 Grommet (In-line) Grommet (In-line) Reed switch Without indicator light 8-12-24

Lead wire (m) 0.5 () Load voltage Auto switch model Indicator Wiring (Output) Specification details Special function Style Electrical entry Load Electrical entry 3 (L) AC DC Perpendicular In-line No A90V A90 100V or less IC circuit 5V, 12V Relay, PLC Reed switch Solid state switch 24V 2 wire A93V A93 100V 12V P.5.3-19 Grommet Yes A96V A96 IC circuit 5V 3 wire(Equiv.

SMC has redesigned the NCQ2 compact cylinder with a new body, making it possible to mount auto switches on any of the 4 surfaces, depending on the installation conditions.  Auto switch mounting grooves have replaced the NCQ2's mounting rails, preventing projection of auto switches and improving ease and safety of work.Double acting, single rod, non-rotating compact cylinder , Bore sizes

SMC has redesigned the NCQ2 compact cylinder with a new body, making it possible to mount auto switches on any of the 4 surfaces, depending on the installation conditions.  Auto switch mounting grooves have replaced the NCQ2's mounting rails, preventing projection of auto switches and improving ease and safety of work.Double acting, single rod, non-rotating compact cylinder , Bore sizes (

Magnet: D (Built-in), Mounting: B [Through Hole (Standard; 12 through 63 Bore)], Bore Size: 50mm, Stroke: 30mm, Body Option: M (Rod End Male Thread), Auto Switch Groove: Z (Auto Switch Mounting Grooves), Auto Switch: M9P--Solid State , Gen. Purpose, 3 Wire PNP, Horizontal

Magnet: D (Built-in), Mounting: B [Through Hole (Standard; 12 through 63 Bore)], Bore Size: 50mm, Stroke: 40mm, Body Option: M (Rod End Male Thread), Auto Switch Groove: Z (Auto Switch Mounting Grooves), Auto Switch: M9P--Solid State , Gen. Purpose, 3 Wire PNP, Horizontal

This is a legacy product. Please contact us for the latest version.sales@ocaire.com

This is a legacy product, and replaced byNCDQ2KB50-25DZ

This is a legacy product. Please contact us for the latest version.sales@ocaire.com

This is a legacy product. Please contact us for the latest version.sales@ocaire.com

This is a legacy product. Please contact us for the latest version.sales@ocaire.com

Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 15, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.05~1.0, Support bracket: Through hole, Port thread type: Rc, Body Options

Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.05~1.0, Support bracket: Through hole, Port thread type: Rc, Body Options

Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.05~1.0, Support bracket: Through hole, Port thread type: Rc, Body Options

SMC has redesigned the NCQ2 compact cylinder with a new body, making it possible to mount auto switches on any of the 4 surfaces, depending on the installation conditions.  Auto switch mounting grooves have replaced the NCQ2's mounting rails, preventing projection of auto switches and improving ease and safety of work.Double acting, single rod, non-rotating compact cylinder , Bore sizes

SMC has redesigned the NCQ2 compact cylinder with a new body, making it possible to mount auto switches on any of the 4 surfaces, depending on the installation conditions.  Auto switch mounting grooves have replaced the NCQ2's mounting rails, preventing projection of auto switches and improving ease and safety of work.Double acting, single rod, non-rotating compact cylinder , Bore sizes

SMC has redesigned the NCQ2 compact cylinder with a new body, making it possible to mount auto switches on any of the 4 surfaces, depending on the installation conditions.  Auto switch mounting grooves have replaced the NCQ2's mounting rails, preventing projection of auto switches and improving ease and safety of work.Double acting, single rod, non-rotating compact cylinder , Bore sizes

Magnet: D (Built-in), Mounting: B [Through Hole (Standard; 12 through 63 Bore)], Bore Size: 50mm, Stroke: 40mm, Body Option: M (Rod End Male Thread), Auto Switch Groove: None (for 12-25 Bore w/o Magnet), Auto Switch: M9P--Solid State , Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: L (3m)

Magnet: D (Built-in), Mounting: B [Through Hole (Standard; 12 through 63 Bore)], Bore Size: 50mm, Stroke: 75mm, Body Option: M (Rod End Male Thread), Auto Switch Groove: None (for 12-25 Bore w/o Magnet), Auto Switch: M9P--Solid State , Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: L (3m)

Magnet: D (Built-in), Mounting: B [Through Hole (Standard; 12 through 63 Bore)], Bore Size: 50mm, Stroke: 50mm, Body Option: M (Rod End Male Thread), Auto Switch Groove: None (for 12-25 Bore w/o Magnet), Auto Switch: A96--Reed, DC Volt, LED, Horizontal, Lead Wire or Prewired Connector: L (3m)