The condition of the generation of micromist can be checked from the oil filler port. 2 2 Fluid Air 1.5 MPa Proof pressure Operating pressure range 0.15 to 1.0 MPa 0.1 to 1.0 MPa 0.03 to 0.1 MPa 0.05 MPa 102 L/min (ANR) Operating pressure differential range Recommended press. differential Note 3) Press. differential setting min. flow 2000 5000 2000 5000 Bowl capacity between levels (cm 3)
: 5000, 9000, Float switch available, AUTO-FEED TANK, AIRLINE EQUIPMENT, ALF AUTO FEED LUBRICATOR, 22, ALF NO SIZE RAKIT/ACCESSORY, 29.10101 lb, ModelPipe sizeOil capacity oz (cm3)Weight lbs (kgf)Float switch specification*VoltageNALT-5-IS-*1~2Air IN: 1/4, OUT: 3/8169 (5000)29.1 (13.2)--100V 0.25A
, SV1000/2000/3000, SY3000/5000/7000, S0700 Solenoid valve Max. number of solenoid valves 32 solenoid coils Output type of solenoid PNP (Negative common) Connected load Solenoid valve with surge voltage suppressor 24 VDC, 1.0 W or less (SMC) Short circuit protection YES Protocol Ethernet POWERLINK Media 100 BASE-TX Fieldbus Communication speed 100 Mbps Communication type Half duplex Node
VQC2000/4000, SY3000/5000, JSY3000/5000 Application series 2 Output type of solenoid PNP Safety Instructions FO1 Orange Fibre-Optic communication diagnostics for Port 1 (XF1).
5000 or or Cooling capacity[W] facility water temperature Cooling capacity[W] facility water temperature 4000 4000 3000 25 25 3000 32 32 40 40 2000 2000 1000 1000 0 0 0 10 20 30 40 50 0 10 20 30 40 50 Circulating fluid temperature[] Circulating fluid temperature[] 50Hz 60Hz *The cooling capacity will be reduced by 300W when option: T and MT are selected.
5000 temperature temperature 4000 4000 25 25 3000 3000 32 32 2000 2000 40 40 1000 1000 0 0 0 10 20 30 40 50 0 10 20 30 40 50 Circulating fluid temperature [] Circulating fluid temperature [] 50Hz 60Hz Fig. 9-4 Cooling capacity(HRS050--20-(BJM)) 9.5 Heating capacity 9.5.1 HRS050-A-20-(BJM) 2000 2000 Ambient Ambient temperature temperature 1500 1500 5 Heating capacity [W] Heating capacity
5000 25 25 4000 4000 32 3000 3000 32 2000 2000 40 40 1000 1000 0 0 0 10 20 30 40 50 0 10 20 30 40 50 Circulating fluid temperature Circulating fluid temperature 60Hz 50Hz Fig. 9-4 Cooling capacity(HRS060--20-(BJM)) 1. 5 1. 5 1. 5 1. 5 1. 5 1. 5 kW kW kW kW kW kW 1 1 1 1 1 1 0. 5 0. 5 0. 5 0. 5 0. 5 0. 5 0 0 0 0 0 0 9.5 Heating capacity 0 2 0 2 0 2 0 1 2 0 1 2 0 1 2 HRS060-A-2050Hz
Time 216000.0 h [>=0h] 7 Travel Gain -1.2 2 Alarm Limits 2 Valve Total Travel 250 [>=0] Dynamic Loop Test Key Figures: 3 Counters 3 Valve Travel Trend 2500.0 [>=0] 4 Events 4 Valve Reversals 10 [>=0] 1 Start Position 10.0 % 5 Device Status 5 Valve Reversals Trend 10 [>=0] 2 End Position 100.0 % 6 Alarms Disabled 6 Valve Rev.SSP Trend 5000 [>=0] 3 Total Testing Time 100.0 sec. 7 Device Status
Description 57026-5000 (for UL1007) 57027-5000 (for UL1015) Crimping tool Puller 57031-6000 307 4 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Series LC6D Connection Examples Electrical wires Wiring numbers 0.5mm or larger (AWG18 to 20) 0.2mm or larger (shielding
Series LC1 controller (vertical specification) Description Part no. 57026-5000 (for UL1007) 57027-5000 (for UL1015) Crimping tool 57031-6000 Puller 87 16 Series LC7R Brake Wiring Example A wiring example for controller (Series LC1) connectors and a brake is shown below. The brake is in a de-energized condition and locked. 24VDC is required to unlock it.
Series LC1 controller (vertical specification) Description Part no. 57026-5000 (for UL1007) 57027-5000 (for UL1015) Crimping tool 57031-6000 Puller 87 91 Series LC7R Brake Wiring Example A wiring example for controller (Series LC1) connectors and a brake is shown below. The brake is in a de-energized condition and locked. 24VDC is required to unlock it.
AC 8 3 standard standard standard Pressure switch 1 2 None E2 E3 E4 E6 E10 S None With pressure switch AV Adapter assembly 4 3 1/4 3/8 1/2 3/4 1 AMR3000/4000 AMR3000/4000 AMR4000/5000 AMR5000/6000 AMR6000 1 standard Port size AU Thread Thread Symbol Port size Applicable model N F Rc (PT) NPT G (PF) Rc(PT) NPT G(PF) N F 02 03 04 06 10 1/4 3/8 1/2 3/4 1 AF The port size of adapter ass'y
denotes the bottom ported type. 3-6-12 13 Explosion Proof Solenoid Valve Series 50-VFE/50-VPE Specifications: 50-VFE3000/5000 Explosion proof solenoid valve 5 port/50-VFE3000, 5000 3 port/50-VPE500, 700 VK 50-VFE3000 50-VFE5000 Series VZ Fluid Air Quality of explosion proof spec.
10 15000 Flow rate L/min (ANR) Flow rate L/min (ANR) AF30 Rc 3/8 AF60 Rc 1 0.10 0.10 P1 = 0.7MPa P1 = 0.5MPa P1 = 0.1MPa 0.08 0.08 P1 = 0.7MPa P1 = 0.3MPa Pressure drop MPa Pressure drop MPa P1 = 0.5MPa P1 = 0.3MPa 0.06 0.06 P1 = 0.1MPa 0.04 0.04 0.02 0.02 00 2000 1000 3000 4000 00 5000 10 15000 Flow rate L/min (ANR) Flow rate L/min (ANR) AF40 Rc 1/2 0.10 P1 = 0.7MPa P1 = 0.5MPa P1 = 0.3MPa
How to Order M8 Connector Cable V100-49-15 D V115 Cable length 1 300 mm Light/surge voltage suppressor 2 500 mm Rated voltage 3 1000 mm Nil Without light/surge voltage suppressor S Z 5 24 VDC 6 12 VDC 4 2000 mm With surge voltage suppressor (Non-polar type) With light/surge voltage suppressor (Non-polar type) 7 5000 mm 1 100 VAC 50/60 Hz DOZ is not available.
It is already built-in to the rectifier circuit. 1 2 3 4 7 300 mm 500 mm 1000 mm 2000 mm 5000 mm 110 VAC 50/60 Hz [115 VAC 50/60 Hz] 3 4 220 VAC 50/60 Hz [230 VAC 50/60 Hz] Electrical entry D With connector DIN terminal DC specifications of type D and DO is only available with 12 and 24 VDC. Power saving circuit is not available in the case of D or DO type.
M8 connector 50 Series SYJ7000 How to Order Connector Assembly for L and M Plug Connector How to Order M8 Connector Cable : SY100-30-4AFor DC V100-49-1: SY100-30-1AFor 100 VAC : SY100-30-2ACable length For 200 VAC 300 mm 1 : SY100-30-3AFor other voltages of AC 500 mm 2 1000 mm 3 2000 mm : SY100-30-A 4 Without lead wire 5000 mm 7 (with connector and 2 of sockets only) Lead wire length Nil
V100-49-15 D V115 Light/surge voltage suppressor Rated voltage Nil Without light/surge voltage suppressor With surge voltage suppressor (Non-polar type) With light/surge voltage suppressor (Non-polar type) S Z 5 24 VDC 6 12 VDC Cable length 1 100 VAC 50/60 Hz 1 2 3 4 7 300 mm 500 mm 1000 mm 2000 mm 5000 mm 2 200 VAC 50/60 Hz DOZ is not available.
P1 = 0.1MPa 0.04 0.04 0.02 0.02 Selection 0 0 15000 10 5000 Warning 1. Do not introduce air from the outlet side as this can damage the damper. Caution 1.
Series LC1 controller (vertical specification) Description Part no. 57026-5000 (for UL1007) 57027-5000 (for UL1015) Crimping tool 57031-6000 Puller 201 Series LC7R Regenerative Absorption Unit Selection Guide The graphs show the relationship between speed and distance where the use of a regenerative absorption unit becomes necessary for each vertical specification actuator based on the desired