40 3 position 28-1co (2-7kgl / cm,) Ambient and fluid temperature Max.120"F(50"C) Lubrication Not required 1 0 2 0 3 0 4 0 5 0 6 0 7 0 Mounting position Free Supply 0ressure [PSl] 15G/3C. (8s^,roooll, 1rp""YMl""tb" *"i"t.
40 3 position 28-1co (2-7kgl / cm,) Ambient and fluid temperature Max.120"F(50"C) Lubrication Not required 1 0 2 0 3 0 4 0 5 0 6 0 7 0 Mounting position Free Supply 0ressure [PSl] 15G/3C. (8s^,roooll, 1rp""YMl""tb" *"i"t.
NA NA F K A A K C H + Stroke S + Stroke H B ZZ + 2 strokes (mm) Bore size (mm) A a B C d E F G GA J K M MA MM NA P R S T V W H ZZ D 0 -0.018 0 -0.021 0 -0.021 0 -0.021 0 -0.025 0 -0.025 0 -0.025 0 -0.062 0 -0.062 0 -0.074 0 -0.074 0 -0.074 0 -0.074 0 -0.087 40 23 10 60 44 18 45 25 14 17.5 M8 x 1.25 18 13 20 M14 x 1.5 30 1/4 37 114 11 7.5 8 66 246 17 50 25 9 73 53 20 50 28 17 17 M10 x 1.5
CB CD DD E F FL LR M MR R NCA1-P150 3/4 1/2 13/32 2 1/2 3/8 1 1/8 3/4 1/2 9/16 1.63 NCA1-P325 1 1/4 3/4 17/32 3 1/2 5/8 1 7/8 1 1/4 3/4 7/8 2.56 CD dia. DD dia. Clevis Bracket AA 2.3 3.6 1 5/8 2 9/16 0.785 1.265 1/2 3/4 1/2 5/8 3/8 -24 1/2 -20 2 1/2 3 1/2 3/8 5/8 1 1/8 1 7/8 1/2 1 1/16 1/2 3/4 9/16 1 1/16 Part no. BA CB CD CW DD E F FL LR M MR NCA1-CB150 NCA1-CB325 DD dia.
to 500 mm/s) 2 to 20 in/s (50 to 500 mm/s) Piston speed (50 to 500 mm/s) CJP Cushion Air cushion standard Basic style, Foot style, Rod side flange style, Head side flange style, Clevis style, Side tapped style, Center trunnion style, Head side trunnion style, Side lug style, Rod side trunnion style Basic style, Foot style, Clevis style, Rod side flange style, Head side flange style, Center
Max. load current or load current range (mA) D-A53 None PLC 5 to 50 24VDC 5 to 50 24VDC 5 to 25 100VAC Relay, PLC D-A54 5 to 12.5 200VAC None D-A56 20 IC circuit 4 to 8VDC 50 24VAC/DC or less None D-A64 25 100VAC Relay, PLC 12.5 200VAC None 30 Max. 24VDC None IC circuit, PLC D-A67 (2 color indication) 5 to 40 Relay, PLC 24VDC D-A59W None PLC 5 to 50 D-A33 24VDC 5 to 50 24VDC D-A34
M M H W Y L E 1/8 LQ1H11-F LQ1H12-F LQ1H21-F LQ1H22-F LQ1H23-F LQ1H24-F LQ1H31-F LQ1H32-F LQ1H33-F LQ1H34-F LQ1H35-F LQ1H36-F LQ1H41-F LQ1H42-F LQ1H43-F LQ1H44-F LQ1H51-F LQ1H52-F LQ1H53-F LQ1H54-F LQ1H61-F LQ1H62-F LQ1H63-F LQ1H64-F 4 3 6 4 6 4 10 8 6 10 8 6 12 10 12 10 19 12 19 12 25 19 25 19 11.5 18.5 10 10 26.5 1/8" Class 1 Rc (NPT) Port size 18.5 35 1/8" 16.5 14 14 15 (L) 21.5 36.5
8.5 9 M18 x 1.5 3/8 55 58 23 12 61.5 321 80 157 26 M10 x 1.5 5 10 38 245 10.5 11.5 M22 x 1.5 3/8 61 72 33 14 69.5 341 100 177 26 M10 x 1.5 5 10 38 265 10.5 17 M26 x 1.5 1/2 68 72 37.5 15 With rod boot (mm) 151 to 200 l 151 to 200 h Bore size (mm) e f 1 to 50 25 25 25 25 25 25 51 to 100 37.5 37.5 37.5 37.5 37.5 37.5 101 to 150 50 50 50 50 50 50 201 to 300 100 100 100 100 100 100 301 to 400
Refer to the cylinder catalog for details. 10 Optimum Actuation Size Chart of Air Cylinder For JSY3000, A, B port: 8 Horizontal Vertical (Upward) Average speed [mm/s] 0 100 200 300 400 500 600 700 800 32 CM2 series Pressure: 0.5 MPa Load ratio: 50% Stroke: 300 mm 40 50 63 CA2 series Pressure: 0.5 MPa Load ratio: 50% Stroke: 500 mm 80 100 125 CS1 series Pressure: 0.5 MPa Load ratio: 50% Stroke
[F 2] OUT2 OUT1 -40No.PF-OMP0001CN-F [F 3] <> [F 3] [F 3][rES] [rES][] [F 3] -41No.PF-OMP0001CN-F [F10] <> [F10] [F10][FLo] [FLo][] [F10] 3) 90 L(9 ft 3 3 3 50 L 60,010 L 203,481,020 L (54 ) (44 ) ((46 )) -42No.PF-OMP0001CN-F [F13] ON <> [F13] [F13][rEv] [rEv][] ON OFF() ON() [F13] -43No.PF-OMP0001CN-F [F20] [---] =00 = ONEEPROM 100+100 OFF <> [F20] [F20][inP] [inP
(60)[F 2]OUT2(36) -24No.PF-OMM0004-D 3 1 [P_1][n_1] 1 1 OUT1OUT2[P_2][n_2] [ tn][ tp] [F 1]OUT1(60)[F 2]OUT2(36) 30 (26) -25No.PF-OMM0004-D 2 [F 1] [F] 2 [F 1] OUT1 60 ON OFF 50% 5% ON OFF [F 2] OUT2 36 ON OFF 50% 5% OUT1 ON OFF 50 5 -26No.PF-OMM0004-D / [F3] 42 1 [F10] 43 [F20] 47 [F22] 48 OFF [F30] 50 OFF[] [F80] 51 [] [F81] 52 OFF [F82] 53 [*]
F F F F F Bore size 20 Bore size 25 800 8 3 7 6 5 4 8 3 7 1 6 4 1 5 500 Stroke (mm) 100 50 0.05 0.1 0.5 1 2 0.05 0.1 0.5 1 2 Load (kN) Load (kN) Bore size 32 Bore size 40 800 6 8 6 4 8 3 7 5 3 7 4 5 1 500 1 Stroke (mm) 100 50 0.05 0.1 0.5 1 2 3 0.1 0.05 0.5 1 2 5 Load (kN) Load (kN) 20 Series CHN Technical Data 3-1 Cylinder Cushion Selection Procedure Caution Use a cylinder cushion within
Calculation of applied lateral load The lateral load F equals the total load of the workpiece. Thus, F= 5 x 0.05 x 9.8 = 2.5 (N) 1. Calculation of applied lateral load F F = N m g (N) = 0.2 x 10 x 0.1 x 9.8 = 2.1 (N) CC 70 Lateral load F (N) RB 60 0.4 MPa 50 J 40 2.
Calculation of applied lateral load The lateral load F equals the total load of the workpiece. Thus, F= 5 x 0.05 x 9.8 = 2.5 (N) 1. Calculation of applied lateral load F F = N m g (N) = 0.2 x 10 x 0.1 x 9.8 = 2.1 (N) CC 70 Lateral load F (N) RB 60 0.4 MPa 50 J 40 2.
auto shift input (Brown) DC (+) 1.2K (Brown) DC (+) (Gray) Analog output (Gray) Auto shift input Main circuit Main circuit Main circuit Main circuit Load Load 1k 12VDC to 24VDC Load Load 6.8K 12VDC to 24VDC (Black) OUT 1 (Black) OUT 1 (White) OUT 2 (White) OUT 2 (Blue) DC () (Blue) DC () ZSE F/ISE --62(L)-(M) 50 60 50 60 ZSE F/ISE --70(L)-(M) 50 60 50 60 With analog output With auto shift
Bore size/Stroke (mm) Data 10 25, 50, 75, 100 16 25, 50, 75, 100, 125, 150, 175, 200 End lock 20 25, 50, 75, 100, 125, 150, 175, 200 25 25, 50, 75, 100, 125, 150, 175, 200 R End lock 32 (25), 50, 75, 100, 125, 150, 175, 200 Nil None Note 1) For (25) stroke, the shock absorber is mounted on a single side of the plate.
External Grip Internal Grip MHK2-12D MHK2-12D 25 20 Pressure 0.6 MPa Pressure 0.6 MPa 20 Gripping force (N) Gripping force (N) 15 0.5 MPa 0.5 MPa 15 0.4 MPa 10 0.4 MPa 10 0.3 MPa 0.3 MPa 5 5 0.2 MPa 0.2 MPa F F 0 0 10 20 30 40 10 20 30 40 50 50 Gripping point L (mm) Gripping point L (mm) MHK2-16D MHK2-16D External grip Series MHK2 Internal grip Series MHK2 50 50 Pressure 0.6 MPa Pressure
Internal Grip External Grip MHKL2-12S MHKL2-12C 20 15 Gripping force (N) Gripping force (N) Pressure 0.6 MPa Pressure 0.6 MPa Pressure 0.6 MPa 15 Pressure 0.6 MPa MHZ 10 0.5 MPa 0.5 MPa 10 MHF 0.4 MPa 0.4 MPa 5 5 MHL 0.3 MPa 0.3 MPa F F 0 0 MHR 10 20 30 40 50 10 20 30 40 50 10 20 30 40 50 Note) In case of single acting type, the value is for stroke center.
50 60 50 7 15 7 (2) (a) No.
~500mm/s) (50~500mm/s) (50~500mm/s) Mounting Basic, foot Basic, foot Basic, foot, rear flange,clevis center trunnion front flange, side tapped side tapped center trunnion, center trunnion side tapped, head trunnion, side lug side lug rod trunnion Non-Rotating Accuracy n/a n/a 0.50c *Rod and head trunnion maximum operating pressure for 325 and 400 bore is up to 150 psi Standard Strokes (in