Description AQ2000 AQ3000 AQ5000 AQ1500 AQ1510 Valve 30093 NBR 30073 30053 30063 30083 r O-ring 9 x 7 x 1 JIS B 2401P-7 NBR CA40-1601 CA50-1602 30066 t Dimensions AQ1500/1510 AQ2000/3000/5000 3-port size (Mounting hole) 3-port size L1 L2 L3 L4 L5 L6 L7 L8 L9 D L1 L2 L3 L4 Model Port size AQ2000 Model Port size 1 8 1 4 M5 x 0.8 AQ1500 23 20 14 3 12.5 12 15 5.5 6.5 3.1 45 40 10 45 , 3 8 1 4
24 27 30 8 2 +0.2 +0.1 17 26H9 +0.052 depth 3 0 30 40 21 4-M5 x 0.8 thread depth 6 M5 x 0.8 (Finger closing port) (Thread for mounting attachment) Auto Switch Mounting Groove Dimensions 30.3 45 20 O S 16 4.5 4.5 23 10 M5 x 0.8 (Finger operating port) 5 MHW2-25D1 Right angle finger type 6.45 5.5 37 18 12 6 15 16 4-M5 x 0.8 (Thread for mounting attachment) 30 45 21 12-10-20 20 180 Angular
24 27 8 2 20 +0.2 +0.1 17 26H9 +0.052 Depth 3 0 30 21 40 4-M5 X 0.8 Depth 6 (Thread for mounting attachment) M5 X 0.8 (Finger closing port) Auto switch mounting groove position 30.3 45 16 O S 4.5 4.5 23 10 M5 X 0.8 (Finger opening port) 5 6.45 MHW2-25D1 5.5 Right angle finger 37 18 12 6 15 16 4-M5 X 0.8 (Thread for mounting attachment) 30 21 45 MHW2-25D.SMHW2, #2 MHW2-25D1.SMHW2, #6 2.8-
DATA OUT 1 2 3 SET 1 2 SET MONOSASHI-KUN AC100V OUT1 COM OUT2 COM COM OUT3 Series Guide Series CE1 Bore size (mm) Available stroke range Standard stroke (mm) Series CEP1 Standard stroke (mm) Bore size (mm) 12 equiv. 250 400 500 300 175 200 150 125 100 75 50 100 25 75 50 25 12 25 to 150 20 equiv. 20 25 to 300 32 25 to 400 40 25 to 600 50 25 to 600 63 25 to 600 CEU1 CEU5 Output transistor system
PF2A703H--28 PF2A703H--68 PF2A706H--28 PF2A706H--68 PF2A703H--29 PF2A703H--69 PF2A706H--29 PF2A706H--69 3000 150 3000 150 6000 300 6000 300 PF2A712H--28 PF2A712H--68 PF2A712H--29 PF2A712H--69 12000 600 12000 600 11 For Water Digital Flow Switch Series PF2W Refer to www.poweraire.com for details of products compatible with overseas standards.
PF2A703H--28 PF2A703H--68 PF2A706H--28 PF2A706H--68 PF2A703H--29 PF2A703H--69 PF2A706H--29 PF2A706H--69 3000 150 3000 150 6000 300 6000 300 PF2A712H--28 PF2A712H--68 PF2A712H--29 PF2A712H--69 12000 600 12000 600 11 For Water Digital Flow Switch Series PF2W Refer to www.smcworld.com for details of products compatible with overseas standards.
Wn Y Y-axis Yn Z-axis Zn X-axis Xn X Wa 65 mm 0 mm 5 mm 0.88 kg 210 65 150 111 Z Wb 150 mm 0 mm 42.5 mm 4.35 kg Wc 150 mm 111 mm 42.5 mm 0.795 kg Wd 150 mm 210 mm 42.5 mm 0.5 kg Y 42.5 5 n = a, b, c, d 3.
Wn Y Y-axis Yn X-axis Xn Z-axis Zn X Wa 65 mm 0 mm 5 mm 0.88 kg 210 65 150 111 Z Wb 150 mm 0 mm 42.5 mm 4.35 kg Wc 150 mm 111 mm 42.5 mm 0.795 kg Wd 150 mm 210 mm 42.5 mm 0.5 kg Y 42.5 5 n = a, b, c, d 3.
Wn Y X-axis Xn Y-axis Yn Z-axis Zn X Wa 5 mm 0 mm 65 mm 0.88 kg 210 65 150 111 Z Wb 42.5 mm 0 mm 150 mm 4.35 kg Wc 42.5 mm 111 mm 150 mm 0.795 kg Wd 42.5 mm 210 mm 150 mm 0. 5kg Y 42.5 5 n = a, b, c, d 3 Composite Center of Gravity Calculation m1 = mn = 0.88 + 4.35 + 0.795 + 0.5 = 6.525 kg 1 m1 X = x (mn x xn) 1 6.525 = (0.88 x 65 + 4.35 x 150 + 0.795 x 150 + 0.5 x 150) = 138.5 mm 1 m1 Y
RS Q G Theoretical Output Rotary Angle (N) RS H A Operating pressure (MPa) Piston area (cm2) Bore size (mm) Rod size (mm) Operating direction 1.0 0.7 0.5 0.3 RZQ Release (Extended stroke end) 80 to 100 (90 10) Counterclockwise (L) Release (Extended stroke end) 80 to 100 (90 10) Clockwise (R) 80 56 40 24 0.8 R 12 6 110 77 55 33 1.1 H MI W S 150 105 75 45 1.5 R 16 8 200 140 100 60 2 H CEP1
Cyl.Dia Mass (kg) T 60" 45' 30' e u 0.01 po.2 p 0.01 It 0.2 p 0.01 p 0.2 tr 0,01 It 0.2 25 100 50 25 12.5 51.8 (87.2) 80 40 20 1 0 32 180 90 45 22.5 54.9 (s5.6) 47.8 53 78.4 39.2 4 2.2 '| .
27 Series VQZ Base Mounted Type Dimensions: VQZ200 Dimenisons: VQZ200 (mm) Valve Scale: 45% Grpmmet (G): VQZ2 5(R)G 01T 02T 2 4.5 Mounting holes 4 32 19.2 Manual override Cover diameter 1.4 R4 Cross sectional area 0.2mm2 A 2 13 34 15 SMC 3 R 1 P 300 (Lead wire length) 40 51 45 22 A port 13.5 16 9 9 17 10.5 M5 x 0.8 External pilot port PE port 1/8 NPTF 1/8 NPTF (Only external pilot type(
Cyl.Dia Mass (kg) T 60" 45' 30' e u 0.01 po.2 p 0.01 It 0.2 p 0.01 p 0.2 tr 0,01 It 0.2 25 100 50 25 12.5 51.8 (87.2) 80 40 20 1 0 32 180 90 45 22.5 54.9 (s5.6) 47.8 53 78.4 39.2 4 2.2 '| .
Temp. rise C (Rated voltage) 5 50 3.5 45 6 55 7.5 55 6 45 8.5 60 11 60 9.5 50 11.5 60 Power consumption W (Holding) Apparent power VA Frequency Hz Model Power Inrush Holding 50 20 11 60 17 7 50 42 18 60 37 12 50 55 22 60 47 18 Application Example AC VX31 Style N.C. (VX31) N.O. (VX31) C.O.
(Values at the initial period) Vibration resistance No malfunction occurred in a one-sweep test between 45 and 2000 Hz. Test was performed at both energized and de-energized states in the axial direction and at the right angles to the main valve and armature.
Bore size [mm] Stroke C D Mounting bolt part no. 5 35 CQ-M3 x 35 L 10 40 CQ-M3 x 40 L 15 45 CQ-M3 x 45 L 20 50 CQ-M3 x 50 L 25 55 CQ-M3 x 55 L 30 60 CQ-M3 x 60 L Material: Chromium molybdenum steel Surface treatment: Zinc chromated 12 5.6 5 35 CQ-M3 x 35 L 10 40 CQ-M3 x 40 L 15 45 CQ-M3 x 45 L 20 50 CQ-M3 x 50 L 25 55 CQ-M3 x 55 L 30 60 CQ-M3 x 60 L 16 4.6 5 40 CQ-M3 x 40 L 10 45 CQ-M3 x
1 14 40 " 56.5 15 25 SO 226 a 11 6 13.5 18 150 92 180 72 315 80 15
Series eLA Dimensions Rear Flange Type/CLAG Name plate \0 indICate locl
80 86 101 35 18 35 36 25 72 17.5 1 88.2 148.5 103.9 45 CCVS02-lG-S 1/2 45 80 86 101 35 18 35 36 25 72 17.5 2 98 148.5 121.8 57 CCVSl1-lG-S M5 X 0.8 5.4 to 7.5 1/2 45 80 86 101 35 18 35 36 25 72 17.5 1 98 148.5 57 88.2 103.9 CCVSl2-lG-S 1/2 45 80 86 101 35 18 35 36 25 72 17.5 1 98 148.5 57 88.2 103.9 CCVSl3-lG-S 1/2 45 80 86 35 36 25 72 17.5 98 57 88.2 CCVSl0-S 3/4 66 107
-01-06 AS2200-01 100 50 0 ANA1 -C08 T0604 200 CM2 32 150 Stroke mm AS2201F -01-06 AS2200-01 100 50 0 200 CM2 40 150 Stroke mm AS2201F -02-06 AS2200-02 100 50 0 Solenoid valve Silencer Tubing Speed controller 200 300 400 500 600 700 800 900 1000 1100 1200 Speed at the end mm/s Applicable related components For details regarding different conditions, make determinations after using the SMC
(Default settings) No malfunction occurred in a one-sweep test between 45 and 2000 Hz. Test was performed in both energized and de-energized states in the axial direction and at right angles to the main valve and armature.