, 75, 100, 125, 150 16 15, 30, 45, 60, 75, 100, 125, 150, 175, 200 RS H A Intermediate strokes by the 1 mm interval are available without using spacers for stroke adjustment.
, 75, 100, 125, 150 16 15, 30, 45, 60, 75, 100, 125, 150, 175, 200 RS H A Intermediate strokes by the 1 mm interval are available without using spacers for stroke adjustment.
Maximum Allowable Load MY3A, MY3B/m1 MY3A, MY3B/m2 MY3A, MY3B/m3 200 50 40 30 100 100 50 40 20 30 50 40 10 20 30 63 63 5 4 20 10 Load weight kg Load weight kg Load weight kg 63 3 40 10 40 5 4 2 3 25 5 4 1 25 40 2 3 25 0.5 0.4 16 2 1 16 0.3 16 1 0.2 0.5 0.1 0.5 1500 1000 500 400 300 200 100 1500 1000 500 400 300 200 100 1500 1000 500 400 300 200 100 MY3B max. MY3A max. MY3B max.
assembling) 39 L 130 4H10depth5 4-M6 x 1depth14 4-M8 x 1.25depth18 80 31 5 4H10depth5 92 B section detail (S=2/1) B (Stroke+145) 25 18 (52) Stroke+188 (92) 10 10 Stroke+240 60 2 60 31 62.5 Reference plane 130 63.5 3 40 (Refer to *4) 1.2 201 85 (For 100 to 150 strokes) 208 (For 200 to 1000 strokes) 92 (Stroke+131) 10 110 100 (44) Stroke69 E-100 F-M5 x 0.8depth10 4-M5 x 0.8depth10 20 20 3-
Surface finish Ra max 10 in. (0.25 m) Standard 7 in. (0.18 m) 5 in. (0.13 m) Code 0 M V X Specification Standard Sub-atmospheric Code V3 L 1 H 2 4 10 40 -30 in.Hg to 30 psig -30 in.Hg to 60 psig -30 in.Hg to 100 psig -30 in.Hg to 160 psig 0 to 200 psig 0 to 400 psig 0 to 1000 psig 0 to 4000 psig -0.1 to 0.2 MPa -0.1 to 0.4 MPa -0.1 to 0.7 MPa -0.1 to 1.1 MPa 0 to 1.4 MPa 0 to 3 MPa 0 to 7
Power supply connector, communication connector Power supply connector Operating temperature range [C] 0 to 40 (No freezing) Operating humidity range [%RH] 90 or less (No condensation) Storage temperature range [C] -10 to 60 (No freezing) Storage humidity range [%RH] 90 or less (No condensation) Weight [g] 200 (Screw mounting), 220 (DIN rail mounting) Note 1) Please note that the version
Check that the main circuit power supply (200 VAC) and controller circuit power supply (200 VAC) are wired correctly. When using the emergency stop SW etc. provided by customer, wire it to the EMG (Forced stop) of the input/output signal(CN6-1). When wiring, I/O connector(LE-CSNA) or I/O cable(LEC-CSNA-1) is required. (EMG (Forced stop) cannot be controlled with CC-Link.)
Next, the viscosity of 15 mPas and the discharge rate of 200 l/min in the required specification example are converted to the discharge rate for fresh water. Since 48% of the fresh water discharge rate is equivalent to 200 ml/min in the required specifications, 200 ml/min 0.48 = approximately 420 ml/min, indicating that a discharge rate of 420 ml/min is required for fresh water. 3.
Switch (when equipped with switch) Internal pilot manifold L: Dimensions n: Stations External pilot manifold L: Dimensions n: Stations L n 4 173 162.5 145 14 L n 4 185.5 175 155.5 15 2 148 137.5 124 12 3 160.5 150 134.5 13 5 185.5 175 155.5 15 6 198 187.5 166 16 7 210.5 200 176.5 17 8 210.5 200 187 12 9 223 212.5 197.5 13 2 160.5 150 134.5 13 3 173 162.5 145 14 5 198 187.5 166 16 6 210.5
, 250, 320, 400, 500 40 800 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500 Refer to page 6-13-20 for Minimum Stroke for Auto Switch Mounting. 50 1200 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500, 600 63 1200 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500, 600 80 1400 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500, 600, 700, 800 100 1500 25, 50, 80, 100, 125, 160, 200, 250
, 250, 320, 400, 500 40 800 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500 Refer to page 6-13-20 for Minimum Stroke for Auto Switch Mounting. 50 1200 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500, 600 63 1200 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500, 600 80 1400 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500, 600, 700, 800 100 1500 25, 50, 80, 100, 125, 160, 200, 250
Direct operation poppet Air, Inert gas 2.0 Al HNBR 20 to 60 10 to 60 (No freezing) Dustproof and jetproof (Equivalent to IP65) Environment with no corrosive or explosive gas 0.2 or less Free 30/150 or less 24/12 VDC, 100/110/200/220 VAC (50/60 Hz) 10% rated voltage B type VCA2: 6.5 W Valve type Fluid Withstand pressure MPa Body material Seal material Ambient temperature C Fluid temperature
Hz 200 VAC, 50/60 Hz 110 VAC, 50/60 Hz 220 VAC, 50/60 Hz JIS Symbol Internal pilot
Example using a 20[mm] Lead Actuator with target travel speed of 500[mm/sec] Rotations per second Travel distance per second Travel distance per rotation Rotation Speed (rpm) = {Speed (mm/s) Lead (mm) }60 (S) = {500 (mm/s) 20 (mm) }60 (s) =1500 (rpm) The rotation speed must be a value between 0 and the allowable actuator speed. The actuator will not operate if set to 0.
Model Model L D L D TCU0805-1-N-X6 TCU0425-1-N-X6 1 N x 8 31 3 to 90 L x 5.2 + 200 N x 4 18 1 3 to 90 L x 5.9 + 200 8 5 TCU0805-2-N-X6 TCU0425-2-N-X6 2 42 3 to 40 L x 3 + 200 N x 16 L x 4.4 + 200 N x 8 2 3 to 90 4 2.5 28 TCU1065-1-N-X6 TCU0425-3-N-X6 1 52 3 to 45 L x 5 + 200 N x 10 N x 12 3 3 to 63 L x 2.9 + 200 28 10 6.5 TCU1065-2-N-X6 TCU0604-1-N-X6 2 3 to 35 N x 20 52 L x 3 + 200 N x 6
Basic mass 0.90 (Foot style 32) Additional mass 0.09/50 st Cylinder stroke 200 (st) 0.90 + 0.09 x 200/50 = 1.26 kg CX MQ RHC Mounting Bracket Part No.
Basic mass 0.90 (Foot style 32) Additional mass 0.09/50 st Cylinder stroke 200 (st) 0.90 + 0.09 x 200/50 = 1.26 kg CX MQ RHC Mounting Bracket Part No.
It is already built-in to the rectifier circuit. 2 200 VAC 50/60 Hz 110 VAC 50/60 Hz [115 VAC 50/60 Hz] 3 Electrical entry 4 220 VAC 50/60 Hz [230 VAC 50/60 Hz] D With connector DIN terminal DO Without connector DC specifications of type D and DO is only available with 12 and 24 VDC. Power saving circuit is not available in the case of D or DO type.
Manifold Specifications SS5Y5-60 SY560 SS5Y3-60 SY360 Model SS5Y7-60 SY760 Applicable valve Manifold type Stacking DIN rail mounted type P (SUP)/R (EXH) type Common SUP/Common EXH Valve stations 2 to 20 stations Note 1) Ports A, B location Valve C10 (10 One-touch fitting) C8 (8 One-touch fitting) C12 (12 One-touch fitting) Ports P, R Rc(PT) 1/8 C4 (4 One-touch fitting) C6 (6 One-touch fitting
N.O. 1 2 3 100 VAC, 50/60 Hz 200 VAC, 50/60 Hz 110 VAC, 50/60 Hz 220 VAC, 50/60 Hz 24 VDC 12 VDC 240 VAC, 50/60 Hz Note) N.O. valve operates properly only when appropriate pressure is applied to the pilot.