Function: Normally Closed, Piping: Body Ported, Body Option: Standard, Voltage: 110VAC 50/60HZ, Lead Wire: M Plug Connector w/Lead Wire 0.3m, Surge Suppressor: Light & Surge Suppressor, Manual Override: Non-locking Push Style, Port Size: Base Mounted w/Sub-plate/Body Ported Mfld M3X0.5, Option: -
Function: 2 (Normally Open), Piping: 2 (Body Ported), Body Option: M (Common EXH), Specifications: Standard, Rated Voltage: 3 (110VAC 50/60HZ), Lead Wire: M (M Plug Connector w/Lead Wire 0.3m), Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: None, Port Size: M3 (Body Ported M3X0.5)
Function: 1 (Normally Closed), Piping: 2 (Body Ported), Body Option: Individual EXH, Specifications: Standard, Rated Voltage: 3 (110VAC 50/60HZ), Lead Wire: M (M Plug Connector w/Lead Wire 0.3m), Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: None, Port Size: M3 (Body Ported M3X0.5)
Function: 1 (Normally Closed), Piping: 2 (Body Ported), Body Option: M (Common EXH), Specifications: Standard, Rated Voltage: 3 (110VAC 50/60HZ), Lead Wire: M (M Plug Connector w/Lead Wire 0.3m), Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: None, Port Size: M3 (Body Ported M3X0.5)
Solenoid Valves, Application: Single Unit, Mounting Orientation: Direct, Voltage: AC110V, Specification: Standard / Low Vacuum Compatible / Lubrication Free / Copper-Free Fluoropolymer Material / Low Current, Valve Type: 3-Port Valve, Actuation: [Single] Single, Status at Power Off: Self-Recovery (Spring Return), Valve Positions: 2-Position Normally Closed, Pipe Port Type: M, Port Size: M3
Function: 1 (2 Position Single), Piping: 2 (Body Ported), Exhaust: 0 (Individual), Specifications: Standard, Voltage: 3 (110VAC 50/60HZ), Lead Wire: M (M Plug Connector w/Lead Wire 0.3m), Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: Non-locking Push Type, Port Size: M3 (Body Ported M3X0.5)
Function: 2 (2 Position Double), Piping: 2 (Body Ported), Exhaust: 0 (Individual), Specifications: Standard, Voltage: 3 (110VAC 50/60HZ), Lead Wire: M (M Plug Connector w/Lead Wire 0.3m), Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: Non-locking Push Type, Port Size: M3 (Body Ported M3X0.5)
Function: 2 Position Single, Piping: Body Ported, Exhaust: Individual, Specifications: Standard, Voltage: 110VAC 50/60HZ, Lead Wire: M Plug Connector w/Lead Wire 0.3m, Surge Suppressor: Light & Surge Suppressor, Manual Override: Non-locking Push Type, Port Size: Body Ported M3X0.5, Option: -, CE Marked: -
Function: 2 Position Double, Piping: Body Ported, Exhaust: Individual, Specifications: Standard, Voltage: 110VAC 50/60HZ, Lead Wire: M Plug Connector w/Lead Wire 0.3m, Surge Suppressor: Light & Surge Suppressor, Manual Override: Non-locking Push Type, Port Size: Body Ported M3X0.5, Option: -, CE Marked: -
Function: Normally Open, Piping: Body Ported, Body Option: Common EXH, Specifications: Standard, Rated Voltage: 110VAC 50/60HZ, Lead Wire: M Plug Connector w/Lead Wire 0.3m, Surge Suppressor: Light & Surge Suppressor, Manual Override: None, Port Size: Body Ported M3X0.5, Bracket: -, CE-Compliant: -
Function: Normally Closed, Piping: Body Ported, Body Option: Individual EXH, Specifications: Standard, Rated Voltage: 110VAC 50/60HZ, Lead Wire: M Plug Connector w/Lead Wire 0.3m, Surge Suppressor: Light & Surge Suppressor, Manual Override: None, Port Size: Body Ported M3X0.5, Bracket: -, CE-Compliant: -
Function: Normally Closed, Piping: Body Ported, Body Option: Common EXH, Specifications: Standard, Rated Voltage: 110VAC 50/60HZ, Lead Wire: M Plug Connector w/Lead Wire 0.3m, Surge Suppressor: Light & Surge Suppressor, Manual Override: None, Port Size: Body Ported M3X0.5, Bracket: -, CE-Compliant: -
VZ VS VFN 4-4-11 12 Series SYJ300 Manifold for Internal Pilot Type Type 20 Applicable solenoid valve SYJ312--M3 SYJ312M--M3 SYJ322--M3 SYJ322M--M3 How to Order A port M3 x 0.5 SS3YJ3 20 05 Stations Bracket Applicable blanking plate assembly SYJ300-10-1A 02 2 stations Nil Without bracket P R R port : : F With bracket M5 x 0.8 20 20 stations P port Note) For more than 10 stations, supply air
N] F=-q x PA+w x PC F=q x PA+(e-q) x PC F=-q x PA+r x PB+(w-e) x PC F=q x PA q, w and e are piston areas.
G 28 3 x M3 x 8 E F G E F G Y Y Y 3 8 8 34 40 18 C C C A A A B B B D D D Dimensions A 100 125 Dimensions A 40 50 Dimensions A 63 80 B 103 129 C 69 89 D 107 135 B 41 52 C 28 36 D 43 54 B 65 83 C 46 58 D 68 85 Model ZPT100HB-A16 ZPT125HB-A16 Model ZPT40HB-A14 ZPT50HB-A14 Model ZPT63HB-A16 ZPT80HB-A16 E 20.5 24 F 32 35.5 G 62 65.5 Y 13 16.5 E 47.5 56 F 60.5 69 G 90.5 99 Y 35.5 44 E 31.5 37 F
J I Pilot port 2 x M5 x 0.8 5.5 +0.025 0 3H9 ( ) depth 1.5 +0.025 0 3H9 ( ) depth 1.5 4.1 (Maximum screw-in depth) 3.5 23 18.9 2.1 (Minimum screw-in depth) B 14 34 3 21 32 17 B N x M3 x 0.512 F 15 2 x M3 x 0.5 thread depth 5 Cross-sectional view B-B N 2 1 x F 11 20 16 18 M 0.5 Pilot port 2 x M5 x 0.8 (Plug: Width across flats 7) I J 5.5 Bottom view of MXQ6A-30Z Z ZZ (NN 1) x H G H 8.3 5.8
x 0.93 x 1 x 0.88) = 0.51 m3/min 3 Selecting a model According to the corrected air flow capacity of 0.43 m3/min, IDF4E will be selected which air flow capacity is 0.52 m3/min at 50 Hz.