servo motor (100/200 VAC) Encoder Incremental 17-bit encoder (Resolution: 131072 p/rev) Horizontal 45 65 Power consumption [W] *5 Vertical 145 175 Horizontal 2 Standby power consumption when operating [W] *6 Vertical 8 Max. instantaneous power consumption [W] *7 445 724 Type *8 Non-magnetizing lock specifications Lock unit Holding force[N] 131 255 157 308 197 385 Power consumption [W] at 20C
O.D. 1/8" 5/32" 5/32" 3/16" 1/4" 5/16" 3/8" 3/8" 1/2" 1/4" 5/16" 3/16" 1/4" 1/8" 5/32" Inch size 3/8" 5/16" 3/16" 1/4" Flow Direction Symbols on Body Meter-out type Meter-in type Flow rate (l/min (ANR)) Controlled flow (Free flow) 100 180 230 260 390 460 660 790 920 1580 1710 Symbol Effective area (mm2) 1.5 2.7 3.5 4 6 7 10 12 14 12 26 Note) Flow rate values are measured at 0.5 MPa and 20C
Symbol Proportional Solenoid Specifications Max. current 1A VEA250,VEA251 Applicable power amplifier 13W(20C, With maximum current) 13(20C) Coil resistance Rated power consumption Class H or equivalent (180C) Coil insulation 140C(With maximum current) Max. temperature rise DIN terminal Electrical entry Manifold Accessory Mounting screw (With washer) M5 X 45 VER2000 VER4000 Model AXT500-13
Burst pressure 25 20C to 60C Nylon 12 Min. bending radius (mm)(1) Operating temperature Material Note 1) The value at temp. of 20C and with O.D. variable rate 10% max.
Note 2) The data for l/min (ANR) refers to the conditions of 20C, 1 atm. pressure and relative humidity of 65%. Note 3) Install a circuit breaker with sensitivity of 30mA.
(mm) 4 6 8 10 12 3.18 4.76 6.35 9.53 12.7 2.5 4 5 6.5 8 2 3.18 4.23 6.35 8.46 Black (B) White (W) Red (R) Blue (BU) Burst Pressure Characteristics Curve Yellow (Y) Green (G) Clear (C) Orange (YR) Nominal size (inch) 5 32 " 5 16 " 1 4 3 8 " 3 16 " 1 8 " 1 2 " " Specifications Fluid Air, Water Max. operating pressure 0.8MPa at 20C Refer to pressure characteristics curve.
N) 17 Double acting Single acting 6 115 30 16 40 MHZ2-16D (N) 10 235 42 20 66 MHZ2-20D (N) Single acting type, normally open 14 430 65 25 104 MHZ2-25D (N) 4 55 6.3 10 MHZ2-10S (N) Normally closed Normally open 6 115 24 16 MHZ2-16S (N) 10 240 28 20 MHZ2-20S (N) 14 435 45 25 MHZ2-25S (N) 12 4 55 10 MHZ2-10C (N) 31 Single acting type, normally closed 6 115 16 MHZ2-16C (N) 56 10 240 20 MHZ2-20C
Item Conductor resistance /km, 20C Characteristics Cable length (L) Assmbly part no. Note Connector manufacturers example Hirose Electric Co., Ltd. Sumitomo 3M Limited Fujitsu Limited Japan Aviation Electronics Industry, Ltd. J.S.T. Mfg.
(Coil temperature: 20C, at rated voltage, without surge voltage suppressor.) Made to Order Specifications (For details, refer to page 3-6-11.)
Membrane Dyer Series IDG Standard specifications/Single style (standard dew point 20C (4F)) Model Standard dew point 20C IDG5 IDG10 IDG20 IDG30 IDG50 Fluid Compressed air Macromolecular membrane dryers that act like filters Range of operating conditions Standard performance conditions Inlet air pressure MPa (psi) 0.3 to 0.85 (43 to 123) 0.3 to 1.0 (43 to 145) Inlet air temperature C (F) Note
Membrane Dyer Series IDG Standard specifications/Single style (standard dew point 20C) Model Standard dew point 20C IDG5 IDG10 IDG20 IDG30 IDG50 Fluid Compressed air Macromolecular membrane dryers that act like filters Range of operating conditions Standard performance conditions Inlet air pressure MPa 0.3 to 0.85 0.3 to 1.0 Inlet air temperature C Note 1) 5 to 55 Ambient temperature C 5
Response Time Note) Based on JISB8375-1981 dynamic performance test (with coil temperature of 20C and at rated voltage).
Residence time of water at 20C is 5.5 x 10-6sec, whereas at 150C is 2.8 x 10-8 sec, or 200 times shorter.
Flow rate conversion Normal condition: 0C, 101.3 kPa, dry air Standard condition: 20C, 101.3 kPa, 65%RH (ANR) Switchable between these conditions.
Operating Pressure Specifications KA 3.0 Bend the tube into a U shape at a temperature of 20C. Fix one end and bend the loop gradually. Measure 2R when the tube breaks or is crushed.
The value of the minimum bending radius is measured at the temperature of 20C as shown in the figure on the right. Bend the tube into U-form at a temperature of 20C. Fix one end and close loop gradually. Measure 2R when the tube breaks or is crushed. MS Fixed end KKA KP LQ MQR T T IDK 487
The value of the minimum bending radius is measured at the temperature of 20C as shown in the figure on the right. 4. Use inner sleeve, taking the removing force into consideration when used with One-touch fittings.
Silver (S1) MS Solid yellow (Y1) Clear yellow (Y2) KKA Neon yellow (Y3) KP Clear orange (YR1) Neon orange (YR2) LQ Nominal size (inch) 1 4 " 3 16" 1 8 " 3 8 " 1 2 " 5 32" 5 16" MQR Nominal size (mm) T T 3.2 IDK Fluid Air/Water 20C 0.8 Max. operating pressure (MPa) Bend the tube into U-form at a temperature of 20C. Fix one end and close loop gradually.
Membrane Dyer Series IDG Standard specifications/Single style (standard dew point 20C) Model Standard dew point 20C IDG5 IDG10 IDG20 IDG30 IDG50 Fluid Compressed air Macromolecular membrane dryers that act like filters Range of operating conditions Standard performance conditions Inlet air pressure MPa 0.3 to 0.85 0.3 to 1.0 Inlet air temperature C Note 1) 5 to 55 Ambient temperature C 5
Burst pressure Burst pressure (MPa) Note) Min. bending radius (mm) 24 20C to 60C Operating temperature Material Nylon 12 Note) The value at temp. of 20C and with O.D. variable rate 10% max.