3 Product image Socket Socket Plug Plug Socket For DeviceNetTM (Plug, A-coded) Number of functional poles M12: 5 pins Key type A-coded (Normal key) DeviceNetTM / CANopen2 5 3 4 4 3 5 1: DRAIN: NC 2: V+: NC 3: V: NC 4: CAN H 5: CAN L 1: DRAIN 2: V+ (Red) 3: V (Black) 4: CAN H (White) 5: CAN L (Blue) 1: 2: 3: CAN GND 4: CAN H 5: CAN L 1 2 Pin assignment 2 1 Plug, A-coded Socket, A-coded (
(Range) (Lwr_Lmt) (Upr_Lmt) -10..10 V -10.50 to +10.45 V -10.45 to +10.50 V -5..5 V 5.25 to + 5.22 V 5.22 to +5.25 V -20..20 mA -21.00 to +20.90 mA -20.90 to +21.00 mA 0..10 V 0.00 to +10.45 V +0.05 to +10.50 V 0..5 V 0.00 to +5.22 V +0.03 to +5.25 V 1..5 V +0.75 to +5.22 V +0.78 to +5.25 V 0..20 mA 0.00 to +20.90 mA +0.10 to +21.00 mA 4..20 mA +3.00 to +20.90 mA +3.10 to +21.00 mA -52No.EX-OMN0034
Control circuit power supply (24 V) L11 Control circuit power supply (0 V) L21 Motor Connector: CNP3 Accessory U Terminal name Function Function details Servo motor power (U) Servo motor power (V) Servo motor power (W) Connect to motor cable (U, V , W) U V W V W 60 Series LECSA Series LECSB Control Signal Wiring Example: LECSA LECSAm-m 2 m or less Note 5) PLC FX3U-mmMT/ES (Manufactured by
V 5 to 1050 0..5 V 0.00 to +5.22 V 0 to 522 +0.03 to +5.25 V 3 to 525 1..5 V +0.75 to +5.22 V 75 to 522 +0.78 to +5.25 V 78 to 525 0..20 mA 0.00 to +20.90 mA 0 to 2090 +0.10 to +21.00 mA 10 to 2100 4..20 mA +3.00 to +20.90 mA 300 to 2090 +3.10 to +21.00 mA 310 to 2100 41 EX## OMS1015-A 7.
port S99 Heavy-duty cord 3-wire (NPN) Yes Yes Yes Yes No No Change threaded hole to through-hole S99V 5 V, 12 V For 10 and 15 Change the screw position S9P Relay, PLC 3-wire (PNP) IC circuit 24 V Grommet Change rotation range S9PV Change rotation range between 0 and 200 90 5 V, 12 V 5 V, 12 V, 24 V Parallel cord Change rotation range between 0 and 110 5 V, 12 V, 100 V 5 V, 12 V, 24 V, 100
, PLC 100 V, 200 V Yes Yes 12 V PLC Terminal conduit 2-wire 24 V 100 V, 200 V DIN terminal Grommet Relay, PLC Diagnostic indication (2-color indication) 3-wire (NPN) IC circuit 24 V 5 V, 12 V 3-wire (PNP) Grommet 100 V, 200 V 12 V 5 V, 12 V 12 V 2-wire IC circuit 3-wire (NPN) Terminal conduit 2-wire Relay, PLC 3-wire (NPN) 3-wire (PNP) IC circuit Diagnostic indication (2-color
: 80 mA Internal voltage drop: 1.5 V or less PF2MC7###-##-L2#-### NPN type Maximum applied voltage: 30 V Maximum load current: 80 mA Internal voltage drop: 1.5 V or less PF2MC7###-##-L3/L4#-### NPN type Maximum applied voltage: 30 V Maximum load current: 80 mA Internal voltage drop: 1.5 V or less L3: Analogue output: 1 to 5 V or 0 to 10 V Output impedance: 1 k L4: Analogue output: 4 to 20
(Range) (Lwr_Lmt) (Upr_Lmt) -10..10 V -10.50 to +10.45 V -10.45 to +10.50 V -5..5 V 5.25 to + 5.22 V 5.22 to +5.25 V -20..20 mA -21.00 to +20.90 mA -20.90 to +21.00 mA 0..10 V 0.00 to +10.45 V +0.05 to +10.50 V 0..5 V 0.00 to +5.22 V +0.03 to +5.25 V 1..5 V +0.75 to +5.22 V +0.78 to +5.25 V 0..20 mA 0.00 to +20.90 mA +0.10 to +21.00 mA 4..20 mA +3.00 to +20.90 mA +3.10 to +21.00 mA -50No.EX-OMN0028
But this is theory; no adiustment is made tor practice when w simply use gauge pressur in bar +11 lf volume V, = 1 ff at a standard absolute pressure of 14.7 psi. is compressed at constant temprature lo a volume V, = 0.5 ft" then: o1.lA P,.V, = P"'V" P"=-t .
But this is theory; no adiustment is made tor practice when w simply use gauge pressur in bar +11 lf volume V, = 1 ff at a standard absolute pressure of 14.7 psi. is compressed at constant temprature lo a volume V, = 0.5 ft" then: o1.lA P,.V, = P"'V" P"=-t .
or less V = 400mm/s 1 0 Over 30mm stroke V = 400mm/s 10 1 5 0.5 25 25 20 Load weight m (kg) 20 Load weight m (kg) 16 1 0.1 16 12 12 0.01 10 50 100 200 0.1 10 50 100 200 Eccentric distance l (mm) Eccentric distance l (mm) MGPL32 to 100 1 1 50mm stroke or less V = 400mm/s 1 2 Over 50mm stroke V = 400mm/s 100 100 100 50 50 80 100 80 63 10 63 Load weight m (kg) Load weight m (kg) 50 5 10 50 40
[] 2.5 1.2 (3) [] 20 1 [J] 5.6 22 145V TND20V-680KB (135[V]) (78) 370V TND10V-221KB (360[V]) 1.
1/4 V V V V V V V AS3ll1FSl-l03 3/8 V V V V V V V AS-FP AS4ll1FSl-l04 1/2 V V VNote 4) V V 10 AS2ll1FSl-G01 1/8 V V V V VNote 4) AS-FM AS2ll1FSl-G02 1/4 VNote 4) V V V V AS-D AS3ll1FSl-G02 1/4 V V V V G Face seal AS3ll1FSl-G03 3/8 V V V V AS-T AS4ll1FSl-G04 1/2 V V VNote 4) Note 1) Without sealant type can be selected as a standard option.
AS3ll1FSGl-l02 1/4 V V V V V V V AS3ll1FSGl-l03 3/8 V V V V V V V AS-FP AS4ll1FSGl-l04 1/2 V V VNote 4) V V 10 AS2ll1FSGl-G01 1/8 V V V V VNote 4) AS-FM AS2ll1FSGl-G02 1/4 VNote 4) V V V V AS-D AS3ll1FSGl-G02 1/4 V V V V G Face seal AS3ll1FSGl-G03 3/8 V V V V AS-T AS4ll1FSGl-G04 1/2 V V VNote 4) Note 1) Without sealant type can be selected as a standard option.
VQZ3000 VFS VS 0.7 0.9 VS7 Bore size (mm) Cylinder speed (mm/s) Base mounted (With sub-plate) Cv Series CJ2 Series CM2 Series CA1 6 10 16 20 25 32 40 40 50 63 80 100 150 300 VQZ1000 Body width 10 450 0.3 V V V 600 750 150 300 VQZ2000 Body width 15 0.6 450 V 600 V V 750 150 300 VQZ3000 Body width 18 0.9 450 V V V V V 600 750 Cylinder speed marked with can be controlled by speed controller
V V V V 28.8 8.5 21 10 9 8.5 9 81 Vacuum port (V port) Note 4) 107 (M5 x 0.8) Note 1) The above dimensions are for ZZQ1-BSB.
V V V V ZA1 B M 1 J1 ZA1 FB M 1 Q1 N2 ZA1 1 Q2 N2 ZA1 FP M 1 K1 M P Circuit diagram Dimensions of the vacuum (V) and air pressure supply (P) port fittings after installation Dimensions after the fittings are installed on the vacuum (V) port, air pressure supply (P) port of a single unit, and the common air pressure supply (P) port of a manifold are shown below.
VALVE TYPES AVAILABLE To operate a solenoid pilot valve in a vacuum s y s t e m , a s e p a r a t e p r e s s u r e s u p p l y m u s t b e s u p p l i e d t o t h e v a l v e t o m o v e t h e s p o o l o r p o p p e t a s d e s c r i b e d a b o v e .