SMC Corporation of America
Elite Part Number Search
Search Results "VVEX4-2-2-B"

/2 B O D Y S I Z E 1 M5 2 1/8, 1/4 Standard 3 3/8 Standard 4 1/2 Standard T H R E A D P O R T S I Z E M5 ...M5 U01 ..1/8 U02 ..1/4 U03 ..3/8 U04 ..1/2 U32 ..10-32UNF 01 ... 1/8 02 ... 1/4 03 ... 3/8 04 ... 1/2 W I T H O N E-T O U C H F I T T I N G S T Y P E 2 Elbow 3 Universal C O N T R O L M E T H O D 0 Meter Out 1 Meter In Courtesy of Steven Engineering, Inc. !

size P , A port R port Body size Port 01 02 02 03 04 04 06 10 10 12 14 20 Nil 01 02 8 1 1 4 1 4 1 3 8 3 Body ported Base mounted 2 1 2 1 5 4 3 1 1 1 1 2 4 1 1 7 4 1 2 1 9 2 Without sub-plate 8 1 2 4 1 Option Description Part no. 0 3 0 3 0 3 0 3 0 3 0 3 VEX1A33 VEX1B33 VEX113 VEX123 VEX133 VEX153 VEX173 VEX193 B Bracket (With bolt and washer) VEX1-18-1A VEX1-18-1A VEX3-32A VEX5-32A VEX7-

Temperature Data A or B = Series IDUS: Data A Series IDFS: Data B Air pressure Data C = 2 Calculate corrected air flow by using A or B and C. Corrected air flow = (Air flow) (Data A x Data C) Corrected air flow = (Air flow) (Data B x Data C) 3 Select a model having an air flow capacity that is higher than the corrected air flow.

M Applicable tubing b Applicable tube a B A Reducer: M-32R-2, M-04R-2 Applicable tubing O.D. x I.D.

2 Float switch Part number: IS400-1 to 2 Min. clearance for maintenance With bracket B With float switch B 374 383 383 382 385 C E Model Port size H 25 18 16 35 35 P 47 47 AL30 AL40 AL40-06 AL50 AL60 1/4, 3/8 1/4, 3/8, 1/2 3/4 3/4, 1 1 324 333 333 332 335 38 40 38 41 45 53 70 75 90 95 54

(A) 2 Manual override VZ 1 B: Locking style (Slotted) : Non-locking push style (Flush) Metal seal Rubber seal 1 (P) 3 (R) VT (A) 2 N.O. 2 VT 1 (P) 3 (R) VP (A) 2 N.C. 3 VG Electrical entry 1 (P) 3 (R) G: Grommet (DC specification) L: L plug connector with lead wire LO: L plug terminal without connector M: M plug connector with lead wire MO: M plug terminal without connector (A) 2 N.O.

Refer to the page 58 for details. 4.5 5 5 Circuit Diagram Power supply terminal block PCW-EC16Z00 PCW-EC16Z01 20 18 16 14 12 10 8 6 4 2 Input/output connector (CS0) 0 1 2 3 4 5 6 7 19 17 15 13 11 9 7 5 3 1 Green Red F E D C B A 9 8 9 8 7 6 5 4 3 2 1 0 F E D C B A 4 3 2 1 CN1 4 3 2 1 CN2 4 3 2 1 CN3 4 3 2 1 CN4 4 3 2 1 CN5 4 3 2 1 CN6 4 3 2 1 CN7 4 3 2 1 CN8 4 3 2 1 CN9 4 3 2 1 CNA 4 3 2 1

Trace the arrow mark from the point A at an ambient temperature 86F (30C) to obtain the intersection B on the curved line for the relative humidity 60%. 2. Trace the arrow mark from the intersection B to obtain the intersection D on the pressure characteristic line for 102 psi (0.7 MPa). 3. Trace the arrow mark from the intersection D to obtain the intersection E. 4.

Refer to front matters 58 and 59 for Safety Instructions and pages 3 to 7 for 3/4/5 Port Solenoid Valve Precautions. 3 position pressure center Operating pressure (MPa) SYA SYJA Flow Characteristics/Mass VZA Flow characteristics 14/2(PA/B) 4/25/3(A/BEA/EB) Function Port size Pilot port size Mass (kg) b Cv b Cv Valve model VFA 2 position single 2 position single 2 position double 3 position

1P (Rc 1/8) VP300-2-2P (Rc 1/4) VP500-2-1P (Rc 1/4) VP500-2-2P (Rc 3/8) VP700-2-1P (Rc 3/8) VP700-2-2P (Rc 1/2) Mounting Screw Tightening Torques M3: 0.6 Nm M4: 1.4 Nm M5: 2.9 Nm VP300-17-1 VP344 SF4--50 VP500-17-1 VP544 VP700-17-1 VP744 How to Order Sub-plate VP 00 2 1 Series Port size Thread type VP744 3/8 1/2 VP544 1/4 3/8 VP344 1/8 1/4 3 5 7 P F N T VP344 VP544 VP744 Rc G NPT NPTF Symbol

The port on the piston rod B side for 10-/12-, 21is plugged since unlike the vacuum, it is not necessary to exhaust from 2 ports.

B Body B Needle Seat ring Needle guide Lock nut Lock nut U seal U seal Cassette Seal O-ring O-ring O-ring O-ring O-ring Gasket Spacer NBR PBT 13 POM, Stainless steel 2 PBT 14 NBR 3 PBT 15 NBR 4 SUS303 16 NBR 5 SUS303 17 NBR 6 SUS303 18 NBR 7 SUS303 19 NBR 8 SUS303 20 NBR, Stainless steel 9 M5 type only SUS303 21 10 POM Note1) SUS303 11 NBR Note 1) 3/16", 3/8" and 1/2" are SUS303. 12 Stainless

EX600-DM E EX600-DM F EX600-DY B EX600-DY E EX600-DY F EX600-DX B EX600-DX C EX600-DX D EX600-DX E EX600-DX F 1 1 2 1 1 Description Function 6 6 6 6 2 3 2 3 Displays the status of the unit. 2 2 5 5 5 5 3 3 4 4 1 1 2 1 1 6 6 6 6 2 3 2 3 2 3 5 5 5 5 3 4 4 Valve plate mounting groove 1 1 6 6 Valve plate (EX600-ZMV ) 1 5 2 2 3 5 5 3 Direct mounting (1)When joining six or more units, fix the middle

Auto switch a b d c Proper mounting positions (mm) A B Bore size (mm) 63 80 100 10 13 17.5 14 18.5 23.5 Proper mounting positions (mm) a b 14 18 17 c 20 24 23 d D-A9 type D-F9 type D-F9 W type 2 6 5 8 12 11 In order that adjacent switches do not misoperate, they should be set within 1mm of the proper mounting positions indicated in the table above.

(mm) TLM0201 2 x 1 2 1 TLM0302 3 x 2 3 2 TLM0425 4 x 2.5 4 2.5 TLM0403 4 x 3 4 3 TLM0604 6 x 4 6 4 TLM0806 8 x 6 8 6 TLM1075 10 x 7.5 10 7.5 TLM1008 10 x 8 10 8 TLM1209 12 x 9 12 9 TLM1210 12 x 10 12 10 TLM1916 19 x 16 19 16 TLM2522 25 x 22 25 22 TLM1613 16 x 13 16 13 Length per roll Color Translucent Translucent Symbol N N R BU B N N N 10 m Red (Translucent) 20 m Blue (Translucent) Roll

/4 1-1/4 1-1/2 1-1/2 2 2 2 2-1/2 25 180 1-1/4 1-1/2 1-1/2 1-1/2 2 2 2 2-1/2 2-1/2 30 240 1-1/4 1-1/2 1-1/2 2 2 2 2-1/2 2-1/2 3 40 300 1-1/2 2 2 2 2 2-1/2 2-1/2 3 3 50 360 1-1/2 2 2 2 2-1/2 2-1/2 2-1/2 3 3 60 450 2 2 2 2-1/2 2-1/2 3 3 3 3-1/2 75 600 2 2-1/2 2-1/2 2-1/2 3 3 3 3-1/2 4 100 750 2 2-1/2 2-1/2 3 3 3 3-1/2 3-1/2 4 125 Pneumatic Pressure Loss Figures in the table below are approximate

/4 1-1/4 1-1/2 1-1/2 2 2 2 2-1/2 25 180 1-1/4 1-1/2 1-1/2 1-1/2 2 2 2 2-1/2 2-1/2 30 240 1-1/4 1-1/2 1-1/2 2 2 2 2-1/2 2-1/2 3 40 300 1-1/2 2 2 2 2 2-1/2 2-1/2 3 3 50 360 1-1/2 2 2 2 2-1/2 2-1/2 2-1/2 3 3 60 450 2 2 2 2-1/2 2-1/2 3 3 3 3-1/2 75 600 2 2-1/2 2-1/2 2-1/2 3 3 3 3-1/2 4 100 750 2 2-1/2 2-1/2 3 3 3 3-1/2 3-1/2 4 125 Pneumatic Pressure Loss Figures in the table below are approximate

industrial robots-Safety JIS B 8370: JIS B 8361: JIS B 9960-1: -(1 :) JIS B 8433-1993: *2) : : : 1. 2. 3. 1. 2. 3. 4