(mm) 4 6 8 10 12 M I.D. (mm) 2.5 4 5 6.5 8 H White (W) D Black (B) Red (R) MS Blue (BU) T Yellow (Y) Green (G) VMG Air/Nitrogen gas/Water (Pure water) (1) Fluid Max. operating pressure (at 20C) 0.7 MPa (2) Min. bending radius (mm) 10 20 25 30 40 Burst pressure Refer to the burst pressure characteristics curve.
) Note 12) Note 12) i ZA Note 11) Pressure unit Name plate, caution plate for bowl, and pressure gauge in imperial units (PSI, F) Digital pressure switch: With unit switching function Note 13) Note 13) Note 13) Note 10) For thread type: NPT.
Plug-inmManifold for VQ1*0* valve, D-sub connector (25 pin standard, 15 pin option), Top or side receptacle position, Maximum 24 stations available as standard, 16 port sizes available, Optional DIN rail mount, MFLD, PLUG-IN, VQ1000, VALVE, VV5Q* MANIFOLD VQ 4/5 PORT, U5, VV5Q* BUILT IN FITTING 2.50775 lb
We guarantee that the product complies with the outline dimensions provided. d.
Construction ASB Series 12 - ASB-D Series 13 - ASB-BD Series 14 - ASB-*H Series 15 - S Revision history A : Added the construction of ASB-BD series Corrected the component contents of ASB-D series B : Added the ASB-*H series 4-14-1, Sotokanda, Chiyoda-ku, Tokyo 101-0021 JAPAN Tel: + 81 3 5207 8249 Fax: +81 3 5298 5362 URL https://www.smcworld.com Note: Specifications are subject to change
Push-turn locking slotted type [Type D] Push down on the manual override with a small flat head screwdriver until it stops. Turn it clockwise by 90 to lock it. Turn it counterclockwise to release it.
ALARM (24) Alarm output 2 NO.1 12 General-purpose input NO.2 COM (12, 25) Common The output terminal common. 3 < 1 > NO.3 13 NO.4 4 NO.5 14 5 NO.0 15 6 NO.1 16 < 2 > 7 NO.2 17 General-purpose output 8 NO.3 18 9 NO.4 19 10 NO.5 20 57 Series LC1 Series LC1 Timing for temporary stop during operation Timing for READY signal generation immediately after turning on power HOLD ON OFF ON OFF Power
Recommended Tightening Torque [Nm] Connection thread Pressure Control Equipment 1/2 3/8 1/4 1/8 Torque 28 to 30 22 to 24 12 to 14 7 to 9 2. Avoid excessive torsional moment or bending moment other than those caused by the equipments own weight as this can cause damage. Support external piping separately. 3.
Recommended Tightening Torque [Nm] Connection thread Pressure Control Equipment 1/2 3/8 1/4 1/8 Torque 28 to 30 22 to 24 12 to 14 7 to 9 2. Avoid excessive torsional moment or bending moment other than those caused by the equipments own weight as this can cause damage. Support external piping separately. 3.
Fieldbus interface connector layout BUS OUT/Port2: M12 4-pin socket, D-coded (SPEEDCON) No. Designation Description 1 TD+ Transmit Data + 2 RD+ Receive Data + 3 TDTransmit Data 4 RDReceive Data BUS IN/Port1: M12 4-pin socket, D-coded (SPEEDCON) No.
D: Contents revised in several places. [September 2016] E: Contents revised in several places.
Auto switch Auto Switch Specifications D-M9N-5(With indicator light) Auto switch model D-M9N-5 Electrical entry direction In-line Wiring 3-wire Output NPN type Applicable load IC circuit,Relay,PLC Power supply voltage 5 , 12 , 24 VDC (4.5 to 28 V) Current consumption 10 mA or less Load voltage 28 VDC or less Load current 40 mA or less Internal voltage drop 0.8 V or less at 10 mA (2 V or less
Correspondence between output data and valve manifold : Output numbers are assigned to stations from side D to U of manifold in order. (See manual of each valve manifold for the directions of side D and U) : Standard manifold is wired in double. Output numbers are assigned to side A and B alternatively. In case of single solenoid valve, output on side B is free.
(Normally open) B 4 VP 5 6 24 VDC 12 VDC Thread type VG Rc Nil G F 7 240 VAC, 50/60 Hz 9 Other VP NPT N Option NPTF T Electrical entry S070 G Grommet D DIN terminal Port size VQ 04 06 10 1 2 Rc T Conduit terminal E Grommet terminal 3 4 Rc Rc 1 VKF Light/Surge voltage suppressor VQZ Nil None S With surge voltage suppressor (Only grommet type is only available.)
VE 3 4 1 3 4, 1 1 1 1 4 1 2 , 2 VY1 G Dimensions: Auto Feed Tank PPA AL Float switch Contact point capacity: AC: 15 VA, DC: 15 W Contact point construction: 1a, 1b Width across flats 12 Float switch Lubrication plug Model A 174 174 234 234 B 70 70 108 108 C 16 16 30 30 D 7 7 7 7 E 91 91 121 121 F 182 182 242 242 G 15 15 16 16 H 24 24 40 40 I 382 382 422 422 J 414 414 472 472 K 428 428 L
Dimensions n L 2 39 31 3 50 42 4 61 53 5 72 64 6 83 75 7 94 86 8 105 97 9 116 108 10 127 119 11 138 130 12 149 141 13 160 152 14 171 163 15 182 174 16 193 185 17 204 196 18 215 207 19 226 218 20 237 229 L1 L2 1.13-11
How to Order VFN212 02 N 5 F D Z CE marking NAMUR Interface Nil Q CE marked product Voltage Thread type 1 100 VAC, 50/60 Hz 2 200 VAC, 50/60 Hz 3 110 to 120 VAC, 50/60 Hz 4 220 VAC, 50/60 Hz 5 24 VDC 6 12 VDC 7 240 VAC, 50/60 Hz Nil Rc (PT) F G (PF) N NPT Electrical entry Solenoid G Grommet E Grommet terminal T Conduit terminal D DIN terminal Nil Single solenoid D Double solenoid Manual
Right Left Right Left IN IN Options (For details, refer to page 12.)
Auto switch Auto Switch Specifications D-M9P (With indicator light) Auto switch model D-M9P Electrical entry direction In-line Wiring 3-wire Output PNP type Applicable load IC circuit,Relay,PLC Power supply voltage DC51224V(4.5 to 28V) Current consumption 10 mA or less Load voltage DC28V or less Load current 40 mA or less Internal voltage drop 0.8 V or less at 10 mA (2 V or less at 40 mA)
L (L) M (M) DC +DIN +-1 2 (G) A C S DIN DIN DIN DIN DIN D 68mm Y 4.57mm T 68mm E 2.32.8mm E, T 1.25-3, 1.25-3S, 1.25Y-3N, 1.25Y-3S D,Y R Y Z EZTZDZLZMZ AC24V (+) D C S VF1000 VF1000 VF1000 VF1000 VF3000 VF3000 VF3000 VF3000 VF5000 VF5000 VF5000 VF5000 () P P(SUP) P A B A(CYL2) B(CYL1) A B EA EB R1(EXH2) R2(EXH1) R1 R2 (B)2 4(A) (B)2 4(A) (R2)3 1 5(R1) (P) (R2)3 1 5(R1) (P) 3(