Body Size: 60, Thread: NPT, Port: 1, Option: C [Float Type Auto Drain (N.C.)], Attachment: S + T, Semi-Standard 1: 1 + 2, Semi-Standard 2: N + R + Z
Body Size: 50, Thread: N (NPT), Port: 10 (1), Option: C [Float Type Auto Drain (N.C.)], Attachment: SV (S + V), Semi-Standard 1: 8 (Metal Bowl w/Level Gauge), Semi-Standard 2: Z (Name Plate, Caution Plate for Bowl, and Pressure Gauge: psi, °F)
Body Size: 60, Thread: N (NPT), Port: 10 (1), Option: C [Float Type Auto Drain (N.C.)], Attachment: ST (S + T), Semi-Standard 1: 12 (1 + 2), Semi-Standard 2: NRZ (N + R + Z)
Body Size: 50, Thread: N (NPT), Port: 10 (1), Option: C [Float Type Auto Drain (N.C.)], Attachment: V (Residual Pressure Relief 3 Port Valve), Semi-Standard 1: 8 (Metal Bowl w/Level Gauge), Semi-Standard 2: Z (Name Plate, Caution Plate for Bowl, and Pressure Gauge: psi, °F)
Regulator Unit Combination: Air Filter + Regulator + Lubricator, Port Size: NPT1, Filter Rating: 5μm, Operating Environment: Air powered tools, Compressed Air Quality: General Dry Air, Maximum Operating Pressure(MPa): 1, Case Material: [Metal] Metal Case with Level Gauge, Case Guard: No, Exhaust Structure: Relief type, Flow Direction: [Standard Flow (Left to Right)] Left to right, Drain Cock
Regulator Unit Combination: Filter Regulator + Lubricator, Port Size: NPT1, Filter Rating: 5μm, Operating Environment: Air powered tools, Compressed Air Quality: General Dry Air, Maximum Operating Pressure(MPa): 1, Case Material: [Metal] Metal Case with Level Gauge, Case Guard: No, Exhaust Structure: Relief type, Flow Direction: [Standard Flow (Left to Right)] Left to right, Drain Cock: [
. -9No.PF-OMJ0016-J Model Indication and How to Order -10No.PF-OMJ0016-J Option 1 Nil W Z with lead wire and connector (2 m) with lead wire and connector (2 m)+ without lead wire Connecter cover (silicone rubber) Option 2 Nil R S without bracket with bracket with bracket (without flow adjustment valve) (with flow adjustment valve) Not applicable to bottom entry type T V with panel mount adapter
Sufx for actuator1 Inch size Metric size S Hard steel roller R Red Color of push button, selector B Black G Green Y Yellow 23 3.2 04 4 06 6 01 1/8" 03 5/32" 07 1/4" For selecting applicable tubing O.D., refer to the Model on page 2. Metric size and inch size types can be visually identied by color of the release button.
Operation type Air operated External pilot solenoid 0 1 Light/Surge voltage suppressor (Only with solenoid) None With surge voltage suppressor (For grommet only) With light/surge voltage suppressor (Except grommet) Nil S Z Thread type Rc G NPT NPTF Nil F N T Sub-plate and gasket part no.
Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: Z (5m), Number: 2 pcs. (Or None in the Case of No Switch), Stroke Options: XB9 (Low Speed, 10 to 50mm/s)
Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: Z (5m), Number: 2 pcs. (Or None in the Case of No Switch), Stroke Options: XB9 (Low Speed, 10 to 50mm/s)
Purpose, 3 Wire NPN, Horizontal, Lead Wire or Prewired Connector: Z (5m), Number: 2 pcs. (Or None in the Case of No Switch), Stroke Options: XB9 (Low Speed, 10 to 50mm/s)
Purpose, 3 Wire NPN, Horizontal, Lead Wire or Prewired Connector: Z (5m), Number: 2 pcs. (Or None in the Case of No Switch), Stroke Options: XB9 (Low Speed, 10 to 50mm/s)
Magnet: D (Built-in), Mounting: B (Through Hole, Standard), Bore Size: 40mm, Water Resistant: None, Port Thread: Bore 12, 16: M Thread; Bore 20 to 50: Rc, Stroke: 20mm, Action: B (Double Acting/Spring Loaded), Rod End: B (Lever Type, Adjustable Absorber Type), Direct Mount Switch Groove: Z (Direct Mount Switch Groove), Mounting Bolt: None, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal
Magnet: D (Built-in), Mounting: B (Through Hole, Standard), Bore Size: 40mm, Water Resistant: None, Port Thread: Bore 12, 16: M Thread; Bore 20 to 50: Rc, Stroke: 20mm, Action: B (Double Acting/Spring Loaded), Rod End: B (Lever Type, Adjustable Absorber Type), Direct Mount Switch Groove: Z (Direct Mount Switch Groove), Mounting Bolt: None, Auto Switch: M9B--Solid State , Gen.
Magnet: D (Built-in), Mounting: B (Through Hole, Standard), Bore Size: 50mm, Water Resistant: None, Port Thread: TN (NPT), Stroke: 20mm, Action: B (Double Acting/Spring Loaded), Rod End: Round Bar Style, Direct Mount Switch Groove: Z (Direct Mount Switch Groove), Mounting Bolt: L (Shipped Together Only for Mounting B), Auto Switch: M9BW--Solid State, 2-color Indication, 2 Wire, Horizontal
Magnet: D (Built-in), Mounting: B (Through Hole, Standard), Bore Size: 32mm, Water Resistant: None, Port Thread: Bore 12, 16: M Thread; Bore 20 to 50: Rc, Stroke: 20mm, Action: T (Single Acting/Spring Extend), Rod End: B (Lever Type, Adjustable Absorber Type), Direct Mount Switch Groove: Z (Direct Mount Switch Groove), Mounting Bolt: L (Shipped Together Only for Mounting B), Auto Switch:
Model: 33, Orifice: 4 (4mm), Style: 2 (N.O., Single Unit), Option: B (C37, Seals: EPDM, Class B), Suffix: Z (Oil-free), Port Size: 03 (3/8), Thread: N (NPT), Voltage: 5 (24VDC), Electrical Entry: G (Grommet), Surge Suppressor: S (w/Surge Voltage Suppressor), Rectifier: None (for DC or AC Class H Coil), Bracket: B (Bracket)
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, F/R/L COMBO MODULAR, AIRLINE EQUIPMENT, AC MASS PRO, HC, AC MASS PRO 1" MODULAR (NPT), 10.80265 lb
Gap too small Green 2 a Place the gap gauge on the detection nozzle for precise adjustment. s Confirm applied air pressure.