15-10 RS Q G RS H A RZQ Series CVM5/CVM5K 20 25 32 40 Standard MI W S 10-15-16 10-15-26 Double acting Nonrotating rod CEP1 CE1 Series CVM3/CVM3K Single acting (Spring return) (Spring extend) CE2 20 25 32 40 Standard 10-15-31 10-15-44 ML2B Nonrotating rod C J G5-S CV Series CV3/CV3K 40, 50 63, 80 100 Standard 10-15-50 MVGQ Double acting Nonrotating rod 40, 50 63 CC 10-15-63 RB Series CVS1/
C, use a 15% aqueous solution of ethylene glycol. Tap water may be frozen in the thermo-chiller which may damage the product. 3.5 Circulating Fluid Supply HRS Series 3-32 HRX-OM-S004 Chapter 3 Transport and Setting Up 15% aqueous solution of ethylene glycol When a 15% aqueous solution of ethylene glycol is used, prepare the ethylene glycol aqueous solution separately.
Assembly / Disassembly procedure 12 4.1 With vertical auto switch unit 12 Size 10, 15 12 Size 20, 30 13 Size 40 14 4.2 With angle adjustment unit 15 4.3 With vertical auto switch unit and angle adjustment unit 16 Size 10, 15 16 Size 20, 30 17 Size 40 18 5.
Ambient temperature (C) Recommended circulating fluids 10 to 45 Tap water, ethylene glycol aqueous solution 15(wt)% -5 to 10 Ethylene glycol aqueous solution 15(wt)% -20 to -5 Ethylene glycol aqueous solution 40(wt)% Circulating fluid temperature(C) Recommended circulating fluids 10 to 35 Tap water, ethylene glycol aqueous solution 15(wt)% 5 to 10 Ethylene glycol aqueous solution 15(wt)%
400 400 m Motorless 200 100 200 200 0 0 2 4 6 8 10 0 0 2 4 6 8 10 0 0 5 10 15 20 0 0 5 10 15 20 LAT Work load [kg] Work load [kg] Work load [kg] Work load [kg] LZ 1000 1000 1000 1000 800 800 800 800 LC3F2 Wall mounting m L5 [mm] L5 [mm] L5 [mm] L5 [mm] 600 600 600 600 L5 Y 400 400 400 400 200 200 200 200 0 0 2 4 6 8 10 0 0 5 10 15 20 0 0 5 10 15 20 0 0 2 4 6 8 10 Work load [kg] Work load
MM 28 28 H 5 5 GB 5 5 GA 8 8 F 4 5 D 15 15 A 10 16 Bore size With air cushion With air cushion type is not available for 21-/22-CJ2.
2 1 0 0 0 0 0 MSB AD LSB -30No.EX-OMN0037CN-A (3) AD F7FFF -3276732767 ()() 15 V 15 V 5000 1000 10001 V 20002 V 30003 V 40004 V 50005 V (5 V-1 V)(5000-1000)1/1000 15 V 1/1000 AD (ab) [V] [mA] 16 10 010 V 15 V 05 V 020 mA 420 mA FFFE7FFF -3276632767 10 5 5 20 20 F7FFE -3276732766 0 1 0 0 4 Byte0 Byte1 CH0 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 MSB AD LSB Byte2 Byte3 CH1 15
When the temperature of the circulating fluid is set to lower than 10oC, use a 15% aqueous solution of ethylene glycol. Tap water may freeze in the thermo-chiller, leading to malfunction. 15% aqueous solution of ethylene glycol When a 15% aqueous solution of ethylene glycol is used, prepare the ethylene glycol aqueous solution separately.
17 14 31.5 15.5 13 15.5 3.4/2.9 5/32 1/4 KQE03-35 1/2-20 17.46 17.46 31.5 15 14 16 3 4 18 KQE04-01 M12x1 14 14 27.5 11 13 16 5.6 3/16 1/8 KQE05-34 9/16-18 17.46 17.46 28.5 13 15 16.5 3.5 4 14 KQE04-02 M12x1 17 14 31 15 13 16 5.6 1/4 1/4 KEQ07-35 9/16-18 17.46 17.46 30.5 14.5 15 17 4.6 6 18 KEQ06-01 M14x1 17 17 28 11 15 17 13.1 5/16 3/8 KQE09-36 3/4-16 22.23 22.23 35.5 15 20 18.5 6 6 14 KQE06
VQ0250 2.7 (0.15) 10 or less 13 or less Double Rubber seal VQ0251 3.6 (0.2) 15 or less 20 or less VQ0 Metal seal VQ0350 2.0 (0.11) 20 or less 26 or less Closed center 50 Rubber seal VQ0351 2.7 (0.15) 25 or less 33 or less Metal seal VQ0450 2.0 (0.11) 20 or less 26 or less Exhaust center Rubber seal VQ0451 2.7 (0.15) 25 or less 33 or less Metal seal VQ1110 3.6 (0.2) 12 or less 15 or less
Stroke + 155 2-M6 x 1 thread depth 13 Stroke + 127 15 10 0.5 46.5 (5) 3.5 27 52 (39) 58 15 [18] Stroke + 127 The dimension inside [ ] shows the location at which the home position switch operates.
59 132 161.5 50 8 12.5 13.5 65 34 15 59 139 176 63 12 16 16 69 30 17 68 153 198 80 15 15 15 77 42 17 74 168 223.5 100 15 20 20 79 38 22 86 187 257.5 336 CHSD Series ISO Standard Hydraulic Cylinder 10 MPa Rod flange: CHSDFY Z + Stroke J MM 2 x RcP PJ + Stroke Y GB GA CHQ Head side cushion valve 4 x FD CHK CHN RD BB D E FY V CHM MA K F FT Air release Rod side air release G CHS CHS Air release
(n 2) (n = 2, 3, 4, 5) D-M9mV 5 5 10 + 10 (n 2) (n = 4, 6) Note 4) D-A9mV 5 10 10 + 15 (n 2) (n = 4, 6) Note 4) D-M9m D-A9m 10 10 15 + 15 (n 2) (n = 4, 6) Note 4) D-M9mWV D-M9mAV 10 15 15 + 15 (n 2) (n = 4, 6) Note 4) D-M9mW 15 15 20 + 15 (n 2) (n = 4, 6) Note 4) D-M9mA 15 20 20 + 15 (n 2) (n = 4, 6) Note 4) D-A7m/A80 D-A7mH/A80H D-A73C/A80C 5 10 15 + 10
Area Differential MPa Pressure Differential MPa (mm2) MPa Water / Air Oil 0.02 3/8 15 VXD2142-03 4.5 80 0.7 0.6 0.02 1/2 VXD2142-04 15 5.5 100 1.5 0.7 0.6 0.02 3/4 VXD2152-06 20 9.5 170 0.7 0.6 Courtesy of Steven Engineering, Inc. !
C, use 15% aqueous solution of ethylene glycol. Otherwise it may cause icing of the fluid. HRS090 Series 3.5Circulating Fluid Supply 3-31 HRX-OMT002 Chapter 3 Transport and Setting Up 15% aqueous solution of ethylene glycol When a 15% aqueous solution of ethylene glycol is used, prepare the ethylene glycol aqueous solution separately.
Bore size (mm) 10 15 25 10 15 25 Auto switch Nil Without auto switch Refer to the table below for auto switch model numbers.
119 99 0.5 1.1 LEC-MR-RB-12 40 15 169 149 1.1 2.4 11 14 11.
Refer to page 204 regarding brake wiring. 600 a = 2000 a = 1000 400 L3 (mm) a = 3000 a 200 L3 Mey 0 5 10 15 Transfer load m (kg) Refer to page 145 for deflection data. 32 33 Standard Motor/Vertical Mount Specification Series LJ1H20 Dimensions/LJ1H202PF Scale: 10% 12.5 9.5 Work piece mounting reference plane LJ1 LG1 LC1 LX LC6D/LC6C Switches 110 67 20 4-M6 x 1 thread depth 15 4-M8 x 1.25 thread
Fig 9-15 Required facility water flow (HRR050-W-20-) 9.7.2 HRR050-W-4030 Facility water flow rate [L/min] 25 20 15 10 5 0 0 5 10 15 20 25 30 35 40 45 Facility water inlet temperature [] The amount of the facilitywater for the opution with rated circulating fluid, cooling capacity which is described in fig.9-10.
CAT.ES20-174 A Compact Type Dual-Rod Cylinder 15, 20, 25, 32 additionally released. Series CXSJ/6, 10, 15, 20, 25, 32 Series CXSJ/6, 10, 15, 20, 25, 32 Auto switches can be installed from 3 directions.