mA and cord length of 2 m Note 2) Between case and whole charging part 8-2.
digit, 7-segment indicator, 2-color display (Red and green) Sampling cycle: 5 times/s Display PF2 2% F .S. 2 digit (at 25C ambient temperature) 2% F .S. 1 digit (at 25C ambient temperature) Display accuracy IF Light up when output is ON (Green) 2% F .S. or less (based on 25C) IP40 Operating: 0 to 50C, Stored: 10 to 60C (No freezing or condensation) Operating and stored: 35 to 85% RH (No condensation
Note 2) Element , element O-ring , element cover 1pc. PBT for each. H-NBR Stainless steel POM The VHS series cannot be disassembled. Parts cannot be shipped separately. 2 Series VHS20/30/40/50 Dimensions VHS40/50 VHS30 VHS20 10 I EXH. EXH. EXH. G H F SUP. SUP.
MH*-OMG0035 PRODUCT NAME Rotary Actuated Air Gripper MODEL / Series / Product Number M(D)HR3-10 M(D)HR3-15 Contents Safety Instructions 1. Product Specifications 2. Operating method or operation 2-1. Design precautions 2-2. Selection 2-3. Mounting 2-4. Air supply 2-5. Piping 2-6. Operating environment 2-7. Lubrication 3. Maintenance 3-1. Notes 3-2. Structural drawing / Parts List 3-3.
cover Set Station no. and Baud rate by using the switches under the cover. 2 7 Ground terminal (FE) Used for grounding. 1: For wiring method, refer to subsection "Wiring" (page 10) in this operation manual. 2: For display and setting method, refer to subsection "Setting" (page 15) in this Technical Specification. -8No.EX-OME0014-F Mounting and Installation Installation Not having mounting
Correct the wiring. 2. Modify the wiring (bending supply. Wiring failure 2. Check if bending stress is being radius and stress). applied to part of the lead wire. Selection of unsuitable model (Selection of wrong electrical entry) Check the part number for the electrical entry. Review the selected model. 10 The display is inverted.
Mey = 1/3 x 3.36 x 9.8 x (50+19)/1000 = 0.76 We = 3.36 A3 = 19 Obtain Meay = 4.2 from Va = 420 in Graph (2). 2' = 0.76/4.2 = 0.18 pitch, yaw moment: Graph (2) 2 = Me/Mea Meay Nm 4.2 420 V mm/s 3-3 Sum of the Load Factors 1 + 2 + 2' = Applicable because 0.008 + 0.15 + 0.18 = 0.34 < 1 Use is possible if the sum of the load factors does not exceed 1. 1 + 2 < 1 8-9-6 6 Model Selection Series
Check if there is a noise source An over current (2)Check if the power supply error (Er1 and 2) is indicated. voltage is in the range of 12 to 24 VDC. (2)Supply power voltage of 12 to 24 VDC.
to 52.5 l/min 5 to 50 l/min 0.5 l/min 0.5 l/pulse 0.5 to 10.5 l/min 0.5 to 10.5 l/min 1 to 10 l/min 0.1 l/min 0.1 l/pulse Accumulated pulse flow rate exchange value (Pulse width: 50 ms) l/min, CFM x 10-2 l/min, CFM x 10-1 Real-time flow rate Accumulated flow Display units Note 1, 2) l, ft3 x 10-1 Operating fluid temperature Linearity Repeatability Temperature characteristics Current consumption
Low Friction: Double Acting Single Rod Series CJ2Q 10, 16 How to Order Bore size 10 16 10mm 16mm Mounting Basic Axial foot Front flange Double clevis Standard stroke (mm) B L F D 10 16 15, 30, 45, 60, 75, 100, 125, 150 15, 30, 45, 60, 75, 100, 125, 150, 175, 200 CJ2Q L 16 60 Standard L 16 60 C73 CDJ2Q With auto switch Number of switches With auto switch (Built-in magnet) 2 1 n S n Auto switch
10 available. 10 10 station NARM2000-4B2 Note1) In case of A1 and B1, a pressure gauge or a plug is mounted at the body side, while in case of A2 and B2, at the manifold side.
CAT.ES100-42 B 2-Color Display Type High-Precision Digital Pressure Switch Series ZSE30/ISE30 Improved, easy-to-read 2-color display 2-Color Display Type High-Precision Digital Pressure Switch Series ZSE30/ISE30 Series ZSE30/ISE30 2-color digital display allows you to choose the setting according to your application requirements. 4 different display settings are available.
C.O. 1 2 1 4.1 4.2 Normally closed Normally open Double acting VNB0 VNB02 VNB03 VN 1 4 7.7 7.8 40 12 (P1) 12 (P1) 10 (P2) LVC 6.3 6.4 2 Air operated LVA 2 (B) 1 (A) 2 (B) 1 (A) 2 (B) 1 (A) 11.4 11.5 50 10 (P2) Note) The flange should be JIS B 2210 10K (ordinary style) or its equivalent.
Silao-Trejo K.M. 2.5 S/N, Predio San Jose del Duranzo C.P. 36100, Silao, Gto., Mexico TEL: 472-72-2-55-00 FAX: 472-72-2-59-44/2-59-46 FRANCE SMC Pneumatique S.A. 1 Boulevard de Strasbourg, Parc Gustave Eiffel, Bussy Saint Georges, F-77600 Marne La Vallee Cedex 3 France TEL: 01-64-76-10-00 FAX: 01-64-76-10-10 CHILE SMC Pneumatics (Chile) S.A. Av. La Montaa 1,115 km. 16,5 P.
Doc No.MH*-OMY0021 PRODUCT NAME Magnet Gripper for Collaborative Robots MODEL / Series / Product Number MHM-25D-X7400A-(DTP/HC10DT/HC10)-(N/P) Contents Safety Instructions . 2 1. List of included items . 4 2. Parts description of the magnet gripper . 6 3. Product Specifications . 8 3-1. How to order . 8 3-2. Specifications . 9 3-3. Gripping force . 10 3-4.
Valve size 16 25 40 50 63 80 Bellows assembly u XL1A16-2-101 XL1A25-2-101 XL1A40-2-101 XL1A50-2-101 XL1A63-2-101 XL1A80-2-101 Nut assembly o XL1A16-10-1 XL1A25-10-1 XL1A40-10-1 XL1A50-10-1 XL1A80-10-1 Bellows assembly * Bellows assembly includes the valve seal 1 (Standard material: FKM).
Do not use a cable longer than 10 m. Consult with SMC for the use with a cable longer than 10 m.
(Example) SS3YJA7-41-03-01. 1 set SYJA714 . 2 sets SYJ700-10-2A . 1 set (Example) SS3YJA5-40-03-01. 1 set SYJA514 . 2 sets SYJ500-10-3A . 1 set The asterisk denotes the symbol for assembly.