Rated Vacuum Range: -100 to 100 kPa, Output Specification: PNP Open Collector 2 Outputs + Copy Function, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: ø6 One-touch Fitting, Elbow Type, Lead Wire: -, Bracket: -, Operation Manual: -
Rated Vacuum Range: -101 to 0 kPa, Output Specification: PNP Open Collector 2 Outputs + Copy Function, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: ø6 One-touch Fitting, Elbow Type, Lead Wire: -, Bracket: -, Operation Manual: -
Rated Vacuum Range: -100 to 100 kPa, Output Specification: PNP Open Collector 2 Outputs + Analog Current Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: ø6 One-touch Fitting, Elbow Type, Lead Wire: -, Bracket: -, Operation Manual: -
Rated Vacuum Range: -101 to 0 kPa, Output Specification: PNP Open Collector 2 Outputs + Analog Current Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: ø6 One-touch Fitting, Elbow Type, Lead Wire: -, Bracket: -, Operation Manual: -
Rated Vacuum Range: -101 to 0 kPa, Output Specification: NPN Open Collector 2 Outputs + Analog Current Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: ø6 One-touch Fitting, Elbow Type, Lead Wire: -, Bracket: -, Operation Manual: -
Rated Vacuum Range: -101 to 0 kPa, Output Specification: NPN Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: ø6 One-touch Fitting, Elbow Type, Lead Wire: -, Bracket: -, Operation Manual: -
Rated Vacuum Range: -100 to 100 kPa, Output Specification: PNP Open Collector 2 Outputs + Copy Function, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: ø6 One-touch Fitting, Elbow Type, Lead Wire: -, Bracket: -, Operation Manual: -
Flow Rate Range: 11 [2 to 100 (50 for CO2) ℓ/min], Flow Adjustment Valve: Yes, Port Size: ø6 One-touch Fitting, Piping Entry Direction: Bottom Side, Output Specification: E [1 PNP Outputs + Analog (1 to 5 V)], Unit Specification: -, Instruction Manual: -, Calibration Certificate: -, Connector: -, Option: -
Flow Rate Range: 11 [2 to 100 (50 for CO2) ℓ/min], Flow Adjustment Valve: Yes, Port Size: ø6 One-touch Fitting, Piping Entry Direction: Bottom Side, Output Specification: 2 PNP Outputs, Unit Specification: -, Instruction Manual: -, Calibration Certificate: -, Connector: -, Option: -
Flow Rate Range: 11 [2 to 100 (50 for CO2) ℓ/min], Flow Adjustment Valve: Yes, Port Size: ø6 One-touch Fitting, Piping Entry Direction: Bottom Side, Output Specification: F [1 PNP Outputs + Analog (4 to 20 mA)], Unit Specification: -, Instruction Manual: -, Calibration Certificate: -, Connector: -, Option: -
Flow Rate Range: 50 [1 to 50 (25 for CO2) ℓ/min], Flow Adjustment Valve: None, Port Size: ø6 One-touch Fitting, Piping Entry Direction: Bottom Side, Output Specification: 2 NPN Outputs, Unit Specification: -, Instruction Manual: -, Calibration Certificate: -, Connector: -, Option: -
Flow Rate Range: 11 [2 to 100 (50 for CO2) ℓ/min], Flow Adjustment Valve: None, Port Size: ø6 One-touch Fitting, Piping Entry Direction: Bottom Side, Output Specification: 2 NPN Outputs, Unit Specification: -, Instruction Manual: -, Calibration Certificate: -, Connector: -, Option: -
Flow Rate Range: 11 [2 to 100 (50 for CO2) ℓ/min], Flow Adjustment Valve: None, Port Size: ø6 One-touch Fitting, Piping Entry Direction: Bottom Side, Output Specification: 2 PNP Outputs, Unit Specification: -, Instruction Manual: -, Calibration Certificate: -, Connector: -, Option: -
Flow Rate Range: 11 [2 to 100 (50 for CO2) ℓ/min], Flow Adjustment Valve: None, Port Size: ø6 One-touch Fitting, Piping Entry Direction: Bottom Side, Output Specification: D [1 NPN Outputs + Analog (4 to 20 mA)], Unit Specification: -, Instruction Manual: -, Calibration Certificate: -, Connector: -, Option: -
Flow Rate Range: 50 [1 to 50 (25 for CO2) ℓ/min], Flow Adjustment Valve: Yes, Port Size: ø6 One-touch Fitting, Piping Entry Direction: Bottom Side, Output Specification: C [1 NPN Outputs + Analog (1 to 5 V)], Unit Specification: -, Instruction Manual: -, Calibration Certificate: -, Connector: -, Option: -
Check using a feeler gauge that the clearance between the position indicator (109) and the electronics cover is 1 mm. 7 ND90 71 en 17 N O I T A C O L S U O D R A Z A H N O I T A C O L S U O D R A Z A H N O N ND9000H Valve Positioner Position Transmitter X300 Ui (Vmax) = 28 V Ii (Imax) = 120 mA Pi (Pmax) = 1 W Li = 53 uH Ci = 22 nF Ex i Barrier + 1 Uo (Voc) 28 V Io (Isc) 120 mA Po 1 W
C2 LECSC2-T 200 to 230 2 2 S2 LECSS2-T 200 to 240 5 5 N2 LECSN2-T 200 to 240 A 10 E2 LECSN2-T-E 200 to 240 92 LECSN2-T-9 200 to 240 I/O cable length P2 LECSN2-T-P 200 to 240 Nil Without cable H Without cable Connector only 1 1.5 [m] Applicable Stroke Table Stroke Size 50 100 150 200 250 300 350 400 450 500 600 700 800 900 1000 1100 1200 25 32 40 -9- AC servo motor LECY* series L E K F S
t t t B1 H1 (mm) (mm) (mm) Dd9 Applicable bore size (mm) L L Dd9 d l l d m t Snap ring Snap ring t m Part No.
Male thread u r y e w e y q y u r y e w u i t q i t q i t q r y e w AS e w q w ASP o Free flow Female thread Male thread ASN Free flow One-touch fitting Male thread AQ ASV AK Component Parts ASS Description Material Note No.
T Connecting thread KBB1-M5 KBB1-M6 KBB3-R1 KBB4-R2 Rc(PT)1 4 Rc(PT)1 8 M6 X 1 M5 X 0.8 T Connecting thread Part No.