SMC Corporation of America
Elite Part Number Search
Search Results "ISE20B-T-C6L-WA2"

Rated Vacuum Range: -101 to 0 kPa, Output Specification: NPN Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: ø6 One-touch Fitting, Elbow Type, Lead Wire: -, Bracket: -, Operation Manual: -

Rated Vacuum Range: -100 to 100 kPa, Output Specification: NPN Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: ø6 One-touch Fitting, Elbow Type, Lead Wire: -, Bracket: -, Operation Manual: -

Rated Vacuum Range: -100 to 100 kPa, Output Specification: PNP Open Collector 2 Outputs + Copy Function, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: ø6 One-touch Fitting, Elbow Type, Lead Wire: -, Bracket: -, Operation Manual: -

Rated Vacuum Range: -101 to 0 kPa, Output Specification: PNP Open Collector 2 Outputs + Copy Function, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: ø6 One-touch Fitting, Elbow Type, Lead Wire: -, Bracket: -, Operation Manual: -

Rated Vacuum Range: -100 to 100 kPa, Output Specification: PNP Open Collector 2 Outputs + Analog Current Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: ø6 One-touch Fitting, Elbow Type, Lead Wire: -, Bracket: -, Operation Manual: -

Rated Vacuum Range: -101 to 0 kPa, Output Specification: PNP Open Collector 2 Outputs + Analog Current Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: ø6 One-touch Fitting, Elbow Type, Lead Wire: -, Bracket: -, Operation Manual: -

Rated Vacuum Range: -101 to 0 kPa, Output Specification: NPN Open Collector 2 Outputs + Analog Current Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: ø6 One-touch Fitting, Elbow Type, Lead Wire: -, Bracket: -, Operation Manual: -

Rated Vacuum Range: -101 to 0 kPa, Output Specification: NPN Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: ø6 One-touch Fitting, Elbow Type, Lead Wire: -, Bracket: -, Operation Manual: -

Rated Vacuum Range: -100 to 100 kPa, Output Specification: PNP Open Collector 2 Outputs + Copy Function, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: ø6 One-touch Fitting, Elbow Type, Lead Wire: -, Bracket: -, Operation Manual: -

Flow Rate Range: 11 [2 to 100 (50 for CO2) ℓ/min], Flow Adjustment Valve: Yes, Port Size: ø6 One-touch Fitting, Piping Entry Direction: Bottom Side, Output Specification: E [1 PNP Outputs + Analog (1 to 5 V)], Unit Specification: -, Instruction Manual: -, Calibration Certificate: -, Connector: -, Option: -

Flow Rate Range: 11 [2 to 100 (50 for CO2) ℓ/min], Flow Adjustment Valve: Yes, Port Size: ø6 One-touch Fitting, Piping Entry Direction: Bottom Side, Output Specification: 2 PNP Outputs, Unit Specification: -, Instruction Manual: -, Calibration Certificate: -, Connector: -, Option: -

Flow Rate Range: 11 [2 to 100 (50 for CO2) ℓ/min], Flow Adjustment Valve: Yes, Port Size: ø6 One-touch Fitting, Piping Entry Direction: Bottom Side, Output Specification: F [1 PNP Outputs + Analog (4 to 20 mA)], Unit Specification: -, Instruction Manual: -, Calibration Certificate: -, Connector: -, Option: -

Flow Rate Range: 50 [1 to 50 (25 for CO2) ℓ/min], Flow Adjustment Valve: None, Port Size: ø6 One-touch Fitting, Piping Entry Direction: Bottom Side, Output Specification: 2 NPN Outputs, Unit Specification: -, Instruction Manual: -, Calibration Certificate: -, Connector: -, Option: -

Flow Rate Range: 11 [2 to 100 (50 for CO2) ℓ/min], Flow Adjustment Valve: None, Port Size: ø6 One-touch Fitting, Piping Entry Direction: Bottom Side, Output Specification: 2 NPN Outputs, Unit Specification: -, Instruction Manual: -, Calibration Certificate: -, Connector: -, Option: -

Flow Rate Range: 11 [2 to 100 (50 for CO2) ℓ/min], Flow Adjustment Valve: None, Port Size: ø6 One-touch Fitting, Piping Entry Direction: Bottom Side, Output Specification: 2 PNP Outputs, Unit Specification: -, Instruction Manual: -, Calibration Certificate: -, Connector: -, Option: -

Flow Rate Range: 11 [2 to 100 (50 for CO2) ℓ/min], Flow Adjustment Valve: None, Port Size: ø6 One-touch Fitting, Piping Entry Direction: Bottom Side, Output Specification: D [1 NPN Outputs + Analog (4 to 20 mA)], Unit Specification: -, Instruction Manual: -, Calibration Certificate: -, Connector: -, Option: -

Flow Rate Range: 50 [1 to 50 (25 for CO2) ℓ/min], Flow Adjustment Valve: Yes, Port Size: ø6 One-touch Fitting, Piping Entry Direction: Bottom Side, Output Specification: C [1 NPN Outputs + Analog (1 to 5 V)], Unit Specification: -, Instruction Manual: -, Calibration Certificate: -, Connector: -, Option: -

K 5 T 5 Angle M 10 Z 10 P 0.5 Q 1 R 2 Angle S 3 T 5 Z 10 DIN rail bracket for controller, high voltage power supply module Symbol For controller For high v oltage power supply module Bracket for nozzle Symbol Type Nil Without bracket Nil None None B With L-type bracket U Included Included F With angle adjustment bracket W Included None Y None Included 1-2-1.

MD0 Automatic/manual selection 10 - (3) Output signal Position control mode: P, Speed control mode: S, Torque control mode: T, Point table method: CP, Program method: CL : Initial setting, : Assignment is available with parameter,: Assignment is not available Symbol Device name P S T CP/ CL Function ALM Trouble This signal turns off while alarm is generated.

D o n o t m a k e a n y a l t e r a t i o n s t o t h i s p r o d u c t . Alterations made to this product may lead to a loss of durability and damage to the product, which can lead to human injury and damage to other equipment and machinery.