AR425 to 935 ARX AMR Winding direction ARM Sealant tape Expose approx. 2 threads ARP Recommended Proper Torque [Nm] Connection thread 1/8 1/4 3/8 1/2 Note) IR-A IR-A Torque 7 to 9 12 to 14 22 to 24 28 to 30 Note) Tightening force for connecting to the EXH port of IR301 2 -A is 8 to 10 Nm. Operating Environment IR Warning IRV 1.
At a time of shipment from the factory, it is set such that the security code is not required. 14 These safety instructions are intended to prevent hazardous situations and/or equipment damage. These instructions indicate the level of potential hazard with the labels of Caution, Warning or Danger.
Also, regularly check there is no deterioration due to ozone. 444 Technical Data IZN10 Series Blow Velocity Distribution (Supply Pressure: 0.3 MPa) IZS (1) Energy saving static neutralization nozzle/IZN10-01 (2) High flow rate nozzle/IZN10-02 IZN IZN IZF ZVB IZD IZE IZH 0 0 100 100 200 200 Distance [mm] Distance [mm] 3 [m/s] 14 [m/s] 300 300 2 [m/s] 11 [m/s] 400 400 1 [m/s] 9 [m/s] 500 30
Process Data Diagnosis items Bit offset Item Note Internal product malfunction Outside of zero-clear range Outside of rated pressure range Upper temperature limit exceeded inside the product 0 OUT1 output 0: OFF 1: ON 1 OUT2 output 0: OFF 1: ON 2 Diagnosis 0: Normal 1: Abnormal 3 to 15 Measured pressure value Unsigned 13 bit Bit offset 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Item Measured
End Plate Model EX245-EA2-1 EX245-EA2-2 Bracket Yes No Weight 200 g 150 g EX245-EA24 EX245 Series Dimensions SI Unit End Plate EX245-SPN1 EX245-EA2-1 120 6.5 14 22.1 28.6 6.6 5.6 98.8 148.5 133.5 61.5 1.6 6 85 10 EX245-EA2-2 37 18 120 14 61.5 44 50 130 23 35 Digital Input Module Digital Output Module EX245-DY1 EX245-DX1 22 22 27 13.5 61 120 120 81 27 54 54 61 5 Fieldbus System: For Input/
14 14 17 17 17 17 17 90 90 90 126 126 126 197 197 30 30 30 60 60 80 120 120 177 177 177 227 227 227 285 285 110 110 110 130 130 130 150 150 120 120 120 140 140 140 170 170 30 310 380 450 520 590 45 385 485 585 685 560 650 750 850 Fixed Connection part dimensions/ Companion flange Female threaded companion flange L-type block companion flange Differential pressure indication switch d Differential
AT Ambient temperature 0.98 B 75 psi (0.53 MPa) Inlet air pressure 0.95 C IDF IDU 14 SCFM Air consumption Note) Values obtained from the table below. IDFA 2 Calculate the corrected air flow capacity. IDFB IDFB Corrected air flow capacity = 14 SCFM (0.82 x 0.98 x 0.95) = 18 SCFM Obtain the corrected air flow capacity from the following formula.
Symbol (B) 2 (A) 4 1 (P) 3 (R) Flow Rate Characteristics C [dm3/(sbar)] b Cv C [dm3/(sbar)] b Cv 14/2(PA/B) 4/25/3(A/BEA/EB) Flow rate characteristics Valve model Port size Body ported 10-VQD1121(V)-L M-M5 10-VQD1121 -L M-M5 10-VQD1151(V)-L M-M5 10-VQD1151W-L M-M5 0.05 0.07 0.06 0.07 Base mounted (With sub-plate) 0.22 0.27 0.22 0.27 0.16 0.24 0.10 0.25 0.05 0.07 0.05 0.07 0.19 0.28 0.22 0.27
through 6 (mm) ST 10 20 30 40 50 14+ST 24 34 44 54 64 17+ST 27 37 47 57 67 49.5+ST 59.5 69.5 79.5 89.5 99.5 61+ST 71 81 91 101 111 Part no.
distributor Auto feed tank 1047
ALF400 to 900, ALT-5/-9 Series Operating Pressure Range Tank and line pressure How to Order
Port size Exhaust cleaner for vacuum pump 10 14 20 30 40 R1 R1 R2 80 (3B) JIS 10K FF flange 1 2 Captures and separates 99.5% of even low-flow and highly concentrated greasy fumes. Using the AMV series, greasy fumes cannot be visibly recognized in the exhaust from the vacuum pump. (When greasy fumes are 1,000 mg/m3 at the IN side, it will be 5 mg/m3 or less at the OUT side.)
max 15 in. (0.4 m) Option: 10 in.(0.25 m), 7in.(0.18 m), 5 in.(0.13 m) Face seal, Tube weld Bottom mount 0.76 in3 (12.52 cm3) Inboard leakage Outboard leakage Leak rate Across the seat leak Surface finish Connections Installation Internal volume Mass Knob LOTO (Lockout) 3 lbs (1.36 kg) 3) Round knob with open/close indication window N/A 3.20 lbs (1.45 kg) 3) Pull twist knob 4) Standard 1) 14
Electroless nickel plated 3 Body B Brass Electroless nickel plated 4 Needle Brass Electroless nickel plated 5 Needle guide Brass Electroless nickel plated (1) 6 Seat ring Brass Zinc chromate plated (3) Meter-out Steel (2) 7 Lock nut Black zinc chromate plated Meter-in 8 U seal HNBR 9 O-ring NBR 10 O-ring NBR 11 O-ring NBR 12 01 to 04 type Bushing PBT 13 01 to 04 type O-ring NBR M3 type PVC 14
Dimensions for installation n: number of valve stations n L 1 2 3 4 5 6 7 8 L1 120.7 136.7 152.7 168.7 184.7 200.7 216.7 L2 80 96 112 128 144 160 176 n L 9 10 11 12 13 14 15 16 L1 232.7 248.7 264.7 280.7 296.7 312.7 328.7 344.7 L2 192 208 224 240 256 272 288 304 (mm) The above table shows dimensions as an example for the SY5000 series valve manifold.
. : : : : : Green flashes EtherNet/IPTM-level communication not established 14 0 1 1 1 NS Green light ON Element Description Multiple EtherNet/IPTM-level communications established DHCP mode 1 1 1 1 CLEAR/HOLD Communication connector Connect the EtherNet/IPTM line.
Remote (2) Mount the end plate bracket (EX600-ZMA2) to the end plate using 2-M4 x 14 screws. Tightening torque: 0.7 to 0.8 Nm 1 2 3 CAUTION indicates a hazard with a low level of risk which, if not avoided, could result in minor or moderate injury.
Remote (2) Mount the end plate bracket (EX600-ZMA2) to the end plate using 2-M4 x 14 screws. Tightening torque: 0.7 to 0.8 Nm 1 2 3 CAUTION indicates a hazard with a low level of risk which, if not avoided, could result in minor or moderate injury.
LCD 3. 4. 5. 14 6. 5 Terminal Setting -13No.EX-OML0010CN-C 15 (I/O ) 24 () 27 () 33 () 47 () -14No.EX-OML0010CN-C 1. I/O Monitor(I/O ) I/O [1.I/O Monitor] 2.& 1. 3. 4. 1. 2.4. 16 2.
Doc.No.LV50***-OMQ0002-G Product Name Electromagnetic Digital Flow Switch Model/ Series/ Product Number LFE# SMC Corporation No.LV50***-OMQ0002-G Contents Safety Instructions 2 Model Indication and How to Order 11 Summary of Product Parts 13 Definitions and Terminology 14 Mounting and Installation 16 Installation 18 Piping Method 19 Wiring 21 Flow Setting 24 Function Settings 26 Default Setting
Doc.No.LFE*-OMZ0012 Product Name Electromagnetic Digital Flow Switch Remote Type Model/ Series/ Product Number LFE#(Z) SMC Corporation Contents Safety Instructions 2 Model Indication and How to Order 11 Summary of Product Parts 13 Definition and Terminology 14 Mounting and Installation 15 Installation 17 Piping Method 18 Wiring 20 Maintenance and Inspection 22 Troubleshooting 23 Specifications