Releasing the residual condensate before ending operations for the day is recommended. 2 If the compressor is smaller than 3.7 kW, or discharge flow is less than 14 scfm [400 L/min (ANR)], air leakage from the drain cock may occur during start of operations. N.C. type is recommended. Proper use of float type auto drain See P.6 3
Body size 2 AMC220 AMC310, 320 AMC510, 520 AMC610 AMC810 AMC910 Refer to page 5-10-14 for Specific Product Precautions. 3 5 6 8 9 Model/Male Thread Type Model Specifications Effective area (mm2) AMC310 AMC510 AMC610 AMC810 AMC910 16 55 165 330 550 Max. air flow (l/min(ANR)) Port size Weight (kg) Element model no.
Port size Exhaust cleaner for vacuum pump 10 14 20 30 40 R1 R1 R2 80 (3B) JIS 10K FF flange 1 2 Captures and separates 99.5% of even low-flow and highly concentrated greasy fumes. Using the AMV series, greasy fumes cannot be visibly recognized in the exhaust from the vacuum pump. (When greasy fumes are 1,000 mg/m3 at the IN side, it will be 5 mg/m3 or less at the OUT side.)
FlowRateandEffectiveArea FlowDirection SymbolonBody AS1002F 3.2,4,6 1/8",5/32" 1/4" 100 1.5 AS2002F 4 AS3002F AS2052F AS4002F 12 Series Metricsize 6 2 8 1/4" 5/16" 460 7 8 6 6 10 10,12 JISsymbol Inchsize TubeO.D. 5/16" 1/4" 5/32" 3/8" 1/4" 3/8" 1/2" Flowrate(l/min(ANR)) 230 3.5 20 0.3 290 4.5 130 2 920 14 660 10 390 6 920 14 1390 21 Controlledflow (Freeflow) Effectivearea(mm2) Note)Flowratevaluesaremeasuredat0.5MPaand20C
Information Akihabara UDX 15F, 4-14-1, Sotokanda, Chiyoda-ku, Tokyo 101-0021, JAPAN URL http://www.smcworld.com 2006 SMC Corporation All Rights Reserved 06-E533 Issued: June, 2006 D-DNP P-120 (DN) Stainless Steel Speed Controller (Elbow Type) Series ASG Flow Rate and Effective Area Material: Stainless steel 316 Model ASG22F-M5 Tubing O.D.
T2 L6 L4 A1 H1 L5 A3 T1 A2 Applicable tubing diameter d A1 A2 A3 D1 D2 H H1 L1 L2 L3 L4 L5 L6 M T T1 T2 Model number 6mm 1/4 1/4 8mm (5/16) 10mm 3/8 12mm 1/2 ASP330F-U01-06-X352 ASP330F-U01-07-X352 ASP430F-U02-07-X352 ASP430F-U02-08-X352 ASP530F-U03-10-X352 ASP530F-U03-11-X352 ASP630F-U04-12-X352 ASP630F-U04-13-X352 45.7 9.4 45.5 G 1/8 51.1 16.1 14 29.3 14 13.7 38.4 22.9 26.9 11.6 14.2 1/
[mm] For 8 For 9 For 10 For 11 Guide pin shape Round type Round type/Diamond type Symbol 115 116 117 118 119 120 125 126 127 128 129 130 135 136 137 138 139 140 145 146 147 148 149 150 Guide pin diameter [mm] 11.5 11.6 11.7 11.8 11.9 12.0 12.5 12.6 12.7 12.8 12.9 13.0 13.5 13.6 13.7 13.8 13.9 14.0 14.5 14.6 14.7 14.8 14.9 15.0 Applicable hole diameter of workpiece [mm] For 12 For 13 For 14
CKQ CLKQ Relay, PLC Note 1) D-P4DWZ 5 m 2-wire (14) 2-color display CK1 D-P79WSE 24 VDC 0.3 m Pre-wired connector DC/AC magnetic field Reed auto switch CLK2 Series C(L)KQP D-P74L 3 m 24 VDC 100 VAC 1-color display 2-wire Grommet D-P74Z 5 m Note 1) PLC: Programmable Logic Controller Note 2) There are other applicable auto switches other than the listed above.
type q Size w Motor size e Lead Finger options 10 16 20 25 32 40 K Basic Nil L Note) Basic Compact Nil: Basic (Tapped in opening/ closing direction) Note) Size: 10, 16, 20, 25 only t Stroke [mm] y Finger options Basic (Tapped in opening/closing direction) Side tapped mounting Through-hole in opening/closing direction Flat fingers Nil A B C Size 10 16 20 25 32 40 Stroke/both sides 4 6 10 14
Note 11) If the product is used at altitude of 1000 m or higher, refer to Operating Environment/Storage Environment (page 210) Item 14 * For altitude of 1000 m or higher. 198 A
For Actuator and Auto Switch Precautions, refer to Handling Precautions for SMC Products and the Operation Manual on SMC website, http://www.smcworld.com OUT IN [Unit: N] Bore size [mm] Rod size [mm] Operating direction Piston area [mm2] Operating pressure [MPa] 0.2 0.3 0.4 0.5 0.6 0.7 32 10 OUT 804 161 241 322 402 483 563 IN 726 145 218 290 363 435 508 40 14 OUT 1257 251 377 503 628 754
0.4 0.5 0.6 0.7 0.8 0.9 1.0 Side porting type -X867 MGF 283 188 314 251 220 157 126 94 63 OUT 314 20 Made to Order (For details, refer to pages 1247 to 1440.) 10 188 118 236 212 165 141 94 71 47 IN 236 MGZ 98 491 442 393 344 295 245 196 147 491 OUT 25 10 Symbol Description 289 82 412 371 330 247 206 165 124 412 IN MGT Withknockpinholes -XC56 804 483 804 724 643 563 402 322 241 161 OUT 32 14
Port thread type 80 80 mm Rc Nil 100 100 mm Table position detector hardware TN NPT Position detector arms Switch bracket Positioning angle Symbol TF G Table unit/ Auto switch a b c d 10 11 12 13 14 15 20 23 25 180 c Nil Without auto switch (Built-in magnet) Stroke (mm) 90 Refer to Standard Stroke on page 452.
Symbol Stroke O.D. thread size 0604 0806 1007 1412 2015 2725 6 mm 4 mm 2 pcs. 1 pc. 8 mm 6 mm 3 pcs. 1 pc. 10 mm 7 mm 1 pc. 14 mm 12 mm Note) RJ0604: "Nil" or "N" only 20 mm 15 mm 27 mm 25 mm With cap Nil U Basic type Collision speed range With urethane cap H L 0.05 to 2 m/s 0.05 to 1 m/s Specifications RJ1007 RJ0604 RJ0806 RJ1412 RJ2015 RJ2725 Basic type RJ0806U RJ1007U RJ1412U RJ2015U
5 Port Air Operated Valve Series VPA450/470 How to Order VPA4 1 5 0 10 VP 5 port Air operated valve Thread type Nil Rc G NPT NPTF Function F N T VPA4270-14 2 position single pilot 2 position double pilot 3 position closed center 3 position exhaust center 1 2 3 4 VPA4150-04 Symbol Port size Applicable valve model Port size Note) 3 position is not available on Series VPA470.
Fluid Nil No L Yes Thread type*1 5 Steam Nil Rc A G B NPT Body material/Port size/Orifice diameter Symbol Body material Port size Orice diameter A Bronze (CAC) *1 The thread type for the main piping and pilot piping is the same. 3/8 11 B 1/2 14 C 3/4 18 D Stainless steel 316L equivalent Pressure type 3/8 11 E 1/2 14 F 3/4 18 Nil Standard H High pressure Other Special Options Special Entry
Through the combination of parallel I/O inputs, 14 points of positioning are available. The speed and acceleration of the positioning can be set by the switch for each operating direction. A single signal sent to a dedicated terminal returns an actuator to the home position.
Through the combination of parallel I/O inputs, 14 points of positioning are available. The speed and acceleration of the positioning can be set by the switch for each operating direction. A single signal sent to a dedicated terminal returns an actuator to the home position.
Through the combination of parallel I/O inputs, 14 points of positioning are available. The speed and acceleration of the positioning can be set by the switch for each operating direction. A single signal sent to a dedicated terminal returns an actuator to the home position.
Through the combination of parallel I/O inputs, 14 points of positioning are available. The speed and acceleration of the positioning can be set by the switch for each operating direction. A single signal sent to a dedicated terminal returns an actuator to the home position.