This is a legacy product. Please contact us for the latest version.sales@ocaire.com
Handling Precautions . 10 5. Names and functions of parts . 10 6. How to use . 11 7. Specification and how to order . 12 8. Discharge capability . 14 9. Troubleshooting . 16 10. Outer dimensions. 18 2 Safety Instructions These safety instructions are intended to prevent hazardous situations and/or equipment damage.
Install it above 0.6m from the floor. 9 Maintenance 10 Troubleshooting 6 Operation Continued 6 Operation Continued 9.1 Daily Check 10.1 Alarm list No. Modes Function Selectable Setting Default No.
Note) 4 6 8 10 12 23 04 06 08 10 12 3.2 TMH-23J TMH-04J TMH-06J ASV Body size AS1001F AS2001F AS2051F AS3001F AS4001F AK TMH-06 TMH-08 ASS TMH-10 TMH-12 Applicable tubing Inch Size ASR Note) Mounting bracket is not available. This is an application example. Applicable tubing size ASF 1/8" 5/32" 3/16" 1/4" 5/16" 3/8" 1/2" 01 03 05 07 09 11 13 Can be mounted on the panel.
Burst prssure Min. bending radius (mm) 10 15 20 27 35 10 15 23 27 35 20 to +60C (Water: 0 to 40C) (No freezing) Polyurethane Operating temperature Material Precautions How to Order Be sure to read before handling.
Note) 4 6 8 10 12 23 04 06 08 10 12 3.2 TMH-23J TMH-04J TMH-06J ASV Body size AS1001F AS2001F AS2051F AS3001F AS4001F AK TMH-06 TMH-08 ASS TMH-10 TMH-12 Applicable tubing Inch Size ASR Note) Mounting bracket is not available. This is an application example. Applicable tubing size ASF 1/8" 5/32" 3/16" 1/4" 5/16" 3/8" 1/2" 01 03 05 07 09 11 13 Can be mounted on the panel.
Fittings & Tubing Air Cylinders Rotary Actuators -ARP20/ARP20K 10 21 -ARP30/ARP30K 10 21 -ARP40/ARP40K 10 21 Clean room compliant, copper-free, fluorine-free, silicone-free Air Preparation Equipment Clean room compliant Description Symbol Body size Body size 30 20 40 20 40 30 Nil 1 Note 4) 3 Note 4) Set pressure c 0.005 to 0.4 MPa setting 0.005 to 0.2 MPa setting 0.008 to 0.6 MPa setting
Fittings & Tubing Air Cylinders Rotary Actuators -ARP20/ARP20K 10 21 -ARP30/ARP30K 10 21 -ARP40/ARP40K 10 21 Clean room compliant, copper-free, fluorine-free, silicone-free Air Preparation Equipment Clean room compliant Description Symbol Body size Body size 30 20 40 20 40 30 Nil 1 Note 4) 3 Note 4) Set pressure c 0.005 to 0.4 MPa setting 0.005 to 0.2 MPa setting 0.008 to 0.6 MPa setting
(Between FG and external terminal) Environment Insulation resistance 10 M or more (500 VDC, Between FG and external terminal) Ambient temperature Working temperature: -10 to +50 oC Storage: -20 to +60 oC Ambient humidity 35 to 85%RH (Non condensing) Operating atmosphere No corrosive gas Standard UL/CSA (E209424), CE marked (EMC directive, RoHS directive) Weight 110 g or less (Including accessories
-10F) 25 5 KKA4 Series (KKA4P-02F+KKA4S-02F) 20 4 15 3 10 2 KKA3 Series (KKA3P-01F+KKA3S-01F) 5 1 KKA7 Series (KKA7P-06F+KKA7S-06F) 0 0 0.1 0 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 0.1 0 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 Pressure MPa Pressure MPa Plug: Without check valve Socket: With check valve Plug: Without check valve Socket: Without check valve 10 10 9 9 KKA6 Series (KKA6P-04M-1+KKA6S
MHL2-10D M4X0.7 2.1 8 MHL2-16D M5X0.8 2.8 7 MHL2-16D M5X0.8 4.3 10 MHL2-20D M6X1 4.8 7 MHL2-20D M6X1 7.3 12 MHL2-25D M8X1.25 12 7 MHL2-25D M8X1.25 17.7 16 MHL2-32D M8X1.25 12 11 MHL2-32D M8X1.25 18 16 MHL2-40D M0X1.5 24 12 MHL2-40D M10X1.5 36 20 Nm MHL2-10D M4X0.7 2.1 MHL2-16D M5X0.8 4.3 MHL2-20D M6X1 7.3 MHL2-25D M8X1.25 17.7 6 - 1. 2. 2 <> AS1200-M5AS2200-01 AS1000AS2000 AS1001FAS2051F
1/8" 03 5/32" 07 1/4" 09 5/16" 11 3/8" 13 1/2" -X214 Restrictor (Without check valve) 04 4 06 6 08 8 10 10 12 12 With One-touch ttings Example) AS2002F-04A-X214 10Clean Series Example) 10-AS2002F-04A 1 For selecting applicable tubing O.D., refer to the Model shown above. 2 Use 1/8" tubing. 1 Fluorine grease is used. 2 The cleanliness class (ISO class) is 5.
Flow Rate and Sonic Conductance Model AS1002FS AS2002FSAS2052FS AS3002FS AS4002FS Metric size 3.2 4 6 4 6 6 8 6 8 10 12 10 12 Tubing O.D.
[L/min (ANR)] 80 m 80 m AFJ20-02-80-S/AFJ30-03-80-S/AFJ40-04-80-S AFJ20-02-80-T/AFJ30-03-80-T/AFJ40-04-80-T 12 12 AFJ20-02-80-T AFJ30-03-80-T AFJ20-02-80-S AFJ30-03-80-S AFJ40-04-80-S 10 10 Pressure drop [kPa] Pressure drop [kPa] 8 8 AFJ40-04-80-T 6 6 4 4 2 2 Water drop removal type Nominal filtration rating: 80 m Large flow type Nominal filtration rating: 80 m 0 0 0 100 200 300 400 500
NFC Reader/Writer Operation Manual EXW1-NT1 P/N:CIR315C-01 IC ID: 21344-WEX06 FCC ID: 2AJE7SMC-WEX06 CAN ICES-3 (B)/NMB-3(B) U.S.
1% F.S.30 msAir/Inert gas0 to 50C (With no condensation)0.88 MPa0.05 MPa to supply pressureSet pressure to 0.88 MPa (VY1 01)1 to 5 VDC, 0 to 10 VDC, 4 to 20 mA DC, 0 to 20 mA DC12 VDC ? 10%, 24 VDC ? 10%, 1.8 W or lessDIN terminalCable O.D. ?4 to 6.5When not operating: Zero, When operating: Max. 10 /min (ANR) (Supply pressure 0.88 MPa)UniversalNot required (3)
2% F.S.30 msAir/Inert gas0 to 50C (With no condensation)0.88 MPa0.05 MPa to supply pressureSet pressure to 0.88 MPa (VY1 01)1 to 5 VDC, 0 to 10 VDC, 4 to 20 mA DC, 0 to 20 mA DC12 VDC ? 10%, 24 VDC ? 10%, 1.8 W or lessDIN terminalCable O.D. ?4 to 6.5When not operating: Zero, When operating: Max. 10 /min (ANR) (Supply pressure 0.88 MPa)UniversalNot required (3)
1% F.S.30 msAir/Inert gas0 to 50C (With no condensation)0.88 MPa0.05 MPa to supply pressureSet pressure to 0.88 MPa (VY1 01)1 to 5 VDC, 0 to 10 VDC, 4 to 20 mA DC, 0 to 20 mA DC12 VDC ? 10%, 24 VDC ? 10%, 1.8 W or lessDIN terminalCable O.D. ?4 to 6.5When not operating: Zero, When operating: Max. 10 /min (ANR) (Supply pressure 0.88 MPa)UniversalNot required (3)
1% F.S.30 msAir/Inert gas0 to 50C (With no condensation)0.88 MPa0.05 MPa to supply pressureSet pressure to 0.88 MPa (VY1 01)1 to 5 VDC, 0 to 10 VDC, 4 to 20 mA DC, 0 to 20 mA DC12 VDC ? 10%, 24 VDC ? 10%, 1.8 W or lessDIN terminalCable O.D. ?4 to 6.5When not operating: Zero, When operating: Max. 10 /min (ANR) (Supply pressure 0.88 MPa)UniversalNot required (3)
1% F.S.30 msAir/Inert gas0 to 50C (With no condensation)0.88 MPa0.05 MPa to supply pressureSet pressure to 0.88 MPa (VY1 01)1 to 5 VDC, 0 to 10 VDC, 4 to 20 mA DC, 0 to 20 mA DC12 VDC ? 10%, 24 VDC ? 10%, 1.8 W or lessDIN terminalCable O.D. ?4 to 6.5When not operating: Zero, When operating: Max. 10 /min (ANR) (Supply pressure 0.88 MPa)UniversalNot required (3)