Output circuit Surge voltage 24 V 0 V Polarity protection diode Diode sol.1: Energized 60 V R Internal circuit Internal circuit Surge voltage Red (+) Coil 0 V PWM circuit sol.2: Deenergized 60 V R Surge voltage 24 V 0 V LED Large capacity load: Energized Black () 60 V R
Lead wire length (m) Load voltage Auto switch model Indicator light Special function Electrical entry Wiring (Output) Pre-wire connector Type 0.5 (Nil) 3 (L) 5 (Z) Applicable load Perpendicular In-line DC AC 3-wire IC circuit Z76 5 V (NPN equivalent) Reed switch Grommet Yes Relay, PLC 2-wire Z73 24 V 12 V 100 V 3-wire (NPN) Y69A Y59A 5 V 12 V IC circuit 3-wire (PNP) Y7P Y7PV 2-wire Y69B
1.5 V 5 V 4 mA 6 mA 20 mA (PF3W711) A B C 1 V 1.4 V 5 V 4 mA 5.6 mA 20 mA (PF3W721) A B C 1 V 1.5 V 5 V 4 mA 5.9 mA 20 mA [L/min] PF3W704 0.5 4 PF3W720 2 16 PF3W740 5 40 PF3W711 10 100 PF3W721 30 250 -79No.PF-OMM0004-D / A B C D 0.6 V 1 V 5 V 5.4 V 2.4 mA 4 mA 20 mA 21.6 mA -80No.PF-OMM0004-D PF3W704/720/740/711 A AA B D E F G H J K L N P PF3W704 3/8 70 50 30 60 40.6 15.2 24 14 35
Find the maximum load speed V. Step 1 Find the maximum load speed V[mm/s] with formula (1) below. The maximum load speed V[mm/s] is approximately equal to V1 x 1.4 . (1) V: Average load speed [mm/s] V = st/t st: Load transfer distance [mm] t: Load transfer time [s] Find the cylinder bore size. Step 2 1. For vertical mounting 2.
Find the maximum load speed V. Step 1 Find the maximum load speed V[mm/s] with formula (1) below. The maximum load speed V[mm/s] is approximately equal to V1 x 1.4 . (1) V: Average load speed [mm/s] V = st/t st: Load transfer distance [mm] t: Load transfer time [s] Find the cylinder bore size. Step 2 1. For vertical mounting 2.
suppressor is used, there is some 100 V 200 V 110 V 220 V residual voltage to the protection element and rated voltage.
1*2 gal/min 6*1*2 V V gal/min 7*1*2 V gal/min Port size Symbol Port size Applicable model LFE1 LFE2 LFE3 3 3/8 V 4 1/2 V 6 3/4 V 8 1 V *1 Options 4, 5, 6, and 7, which are not in SI units, are not for use in Japan due to the New Measurement Law. *2 Options 4, 5, 6, and 7 cannot be selected when the output specification is J or K.
PLC 100 V, 200 V Yes Yes 12 V PLC Terminal conduit 24 V 2-wire 100 V, 200 V DIN terminal Grommet Relay, PLC Diagnostic indication (2-color indication) 3-wire (NPN) IC circuit 24 V 5 V, 12 V 3-wire (PNP) Grommet 100 V, 200 V 12 V 5 V, 12 V 12 V 2-wire 3-wire (NPN) IC circuit Terminal conduit Relay, PLC 2-wire 3-wire (NPN) 3-wire (PNP) IC circuit 24 V Diagnostic indication (2-color
/ sensors) 24 V (valves / loads) 0 V (valves / loads) FE 24 V (logic / sensors) 0 V (logic / sensors) 24 V (valves / loads) 0 V (valves / loads) FE BUS BUS Fig. 11-3 Block diagram of the EX245-DX1 74 No.EX##-OMY0004 12.
For example, when analogue output is 1 to 5 V, F.S. = 5 [V] 1 [V] = 4 [V]. (Reference: 1%F.S. = 4 [V] 1% = 0.04 [V]) F.S. (full span/ full scale) H Hysteresis The difference between ON and OFF points used to prevent chattering. Hysteresis can be effective in avoiding the effects of pulsation.
Switch Characteristics Contact point configuration Maximum contact point capacity Operating voltage: AC, DC 1a 2 VA(AC), 2 W(DC) 100 V or less 12 V to 24 V AC, DC: 50 mA 48 V AC, DC: 40 mA 100 V AC, DC: 20 mA Maximum operating current 25 Series AC Accessories (Spacers/Brackets) Spacer AC AFARAL AWAL AFAR AFAFMAR AWAFM AF AFM / AFD AR AL AW Attachment Center of F.R.L. body D X-X B C X Y200
Clearance For Maintenance W E G A AC-B AA M J N F (2) P1 (Port Size) C B Q Q V IN OUT K P2 (Gauge Port Size) Bracket and Relief Valve (Optional) U Min.
B5 White Unused 1) NPN type Ionizer (IZS41, IZS42) When an ionizer (IZS41) is used in DC mode, make sure to ground the F.G. cable (green) and 0 V cable (blue) Shield Green: F.G. +24V F.G. Brown (2pcs.): +24 VDC + DC/DC + +24 V Power supply 24 VDC Blue (2pcs.): 0 V 0 V 0 V 0 V F.G. PLC INPUT Internal circuit F.G.
Reed Switch: Direct Mounting Style D-A90(V)/D-A93(V)/D-A96(V) . Solid State Switch: Direct Mounting Style D-M9N(V)/D-M9P(V)/D-M9B(V) . 2-color Indication, Solid State Switch: Direct Mounting Style D-F9NW(V)/D-F9PW(V)/D-F9BW(V) . Safety Instructions . Warning . Actuator Precautions . Caution on Design . Selection . Mounting . Piping. Lubrication . Air Supply. Operating Environment.
F.S. = 5[V] 1[V] = 4[V] 3[%F.S.] = 4 X 0.03 = 0.12[V] Detection Analog output voltage [V] Pressure indication [kPa] Switch The output error induced by the temperature change can be as much as 0.12[V]. 1.12 1 0.88 P3 0 Vacuum Pressure Rated pressure P1 P2 103 100 97 Pressure display = 100[kPa] Temperature characteristic = 3[%F.S.]
V V V V V V Clevis pin V Single knuckle joint V V V V V V V Double knuckle joint (with pin) V V V V V V V Option With rod boot V V V V V V V * Refer to page 690 for dimensions and part numbers of the option.
Lead 5: LES16K 3 Work load [kg] T1 = V/a1 = 220/5000 = 0.04 [s], Lead 10: LES16J 2 T3 = V/a2 = 220/5000 = 0.04 [s] T = T1 + T2 + T3 + T4 [s] T2 = L 0.5 V (T1 + T3) V T1: Acceleration time and T3: Deceleration time can be obtained by the following equation. 1 0 = 50 0.5 220 (0.04 + 0.04) 220 0 100 200 300 400 500 T1 = V/a1 [s] T3 = V/a2 [s] Speed [mm/s] = 0.19 [s]
V Relay, PLC 2-wire IC circuit 5 V, 12 V 12 V 100 V or less 24 V Connector IC circuit 5 V, 12 V Water resistant type auto switches can be mounted on the above models, but in such case SMC cannot guarantee water resistance.
AC20A to 40A AW + AL + [V] Residual pressure relief 3 port valve V AC20B to 50B AF + AR + [V] Accessory AC20C to 40C AF + AFM + AR + [V] AC20D to 40D AW + AFM + [V] Description Symbol Applicable model [V] + AF + ARK AC20B to 50B Nil C D E Residual pressure relief 3 port valve V1 [V] + AF + AFM + ARK AC20C to 40C AC10 to 60 Float type auto-drain (N.C.) (4) [V] + AWK + AFM AC20D to 40D