M5 R06 R07 N01 Port size M5 x 0.8 male thread 6 reducer type 1/4 inch reducer type Wetted parts material Pressure sensor: Silicon, O-ring: NBR Body: Stainless steel 304 Body: PBT With sensor cable (3 m) 41 g 38 g Mass Without sensor cable 7 g 3.8 g -12No.PS-OME0004-G Analog output Range Rated pressure range A B C For vacuum 0 to -101 kPa 0 -101 kPa 10.1 kPa For compound -101 to 101 kPa -101
Dimensions 24 SI unit Model indication and How to order 25 Summary of Product parts 26 Mounting and Installation 27 Installation 27 Setting 29 Specification 30 Specifications 30 Dimensions 32 Input Unit Manifold Model indication and How to order 33 Summary of Product parts 34 Mounting and Installation 35 Installation 35 Wiring 35 Setting 39 Specification 40 Specifications 40 Dimensions 41
Refer to each makers manual etc. for details. 2: The power supply for the output equipment must use the one which suits PELV (Protection Extra Low Voltage) demanded of IEC364-4-41. 3: Current consumption inside SI unit. 4: Refer to the input block operation manual for details. 5: Power for input equipment is supplied from communication power. 6: The AS-Interface circuit provides current to
(Refer to page 41) -33No.EX-OML0011-C 1. Selection of parameter Explanation of screen a) Name of each parameter to be set b) The next parameter is displayed with the and buttons. c) Parameters that can be set in each unit only. d) Parameters that can be set in each channel only. 2.
Power supply connector . 38 6.1 Connector specifications . 38 (1) Main control power supply connector: C PWR . 38 (2) Motor drive power connector: M PWR . 38 (3) Motor control power supply connector: CI . 39 6.2 Wiring . 40 (1) Wiring of the power supply connector. 40 (2) Wiring of the stop switch . 41 7. EtherNet/IP communication connector . 43 8.
Note 3) For BUSY and AREA signals, use BUSY1 to BUSY4 and AREA1 to AREA4 for I/O2 (optional). 41 No.SFOD-OMT0010-B (2) I/O2 -Input side Pin No. Signal name Description 1 +COM3 Connects the power supply 24 V to the input/output signals For BUSY1 to BUSY4, AREA1 to AREA4, INP1 to INP4, and ALARM1 to ALARM4. 21 +COM4 2 22 3 23 4 24 5 25 N.C. Unused 6 26 7 27 8 28 9 29 -Output side Pin No.
Troubleshooting 41 10-2. Counter error indication 43 Chapter 1: Read Before Use These safety instructions are intended to prevent a hazardous situation and/ or equipment damage. These instructions indicate the level of potential hazard by label of Caution, Warning or Danger. To ensure safety, follow the below instructions as well as other safety instructions.
Follow the items below to prevent the generation of abnormalities in the product. 41 - Doc. no. ZQ-OM00801-D 1. Use voltage within the rated voltage. 2. Do not lubricate the supply air. 3. Do not directly apply liquid such as water on the body. 4. Do not apply a strong impact. 5. Do not mix drain or dust in the supply air. 6.
(page 27, 38 and 41) -42No.PS-OMW0005-C
[F 4] Auto-preset function This function will automatically calculate and set the optimum pressure based on the actual operating condition, when hysteresis mode has been selected.
material: SUS304) 7 5 Valve (material: SUS304) 2 C C C C D D D D Valve seal (maintenance part) 4 Body (material: A6063) C C C C E E E E E E E E (K flange ) F F F Fn n n n (KF flange) F F F Fd d d d Heater (option) Auto switch (option) G G G G H H H H B B B B A A A A A A A A Unit: mm Model A B C D E Fn Fd G H XLF-16 40 103 38 1 30 17 40 XLF-25 50 113 48 1 12 40 26 39 XLF-40 65 158 66 2 11 55 41
D-P3DW Auto switch Figure-17 Auto switch D-P3DW model Bore size A B Hs Ht 50 14.5 6.5 41 35 63 16.5 10 47 44 80 30.5 17 55 54 * Auto switch mounting bracket is necessary for mounting the D-P3DW type. If you order the switch alone, the auto switch mounting bracket can be ordered using the part number below.
When accumulated pulse output mode is selected: Refer to page 41. -37No.PF-OMS0002-B a. When hysteresis mode is selected Set value [P_2] or [n_2] is displayed on the main display. [The current set value] flashes on the sub display. Press the or button to change the value. Press the button to set. Hysteresis [H_2] is displayed on the main display.
ON US2 is present. 41 No.EX-OMW0011-B 6.4.4.
With shock absorber (mm) With bumper bolt (mm) (mm) (NC) Y: Minimum (NA) X: Minimum necessary space necessary space 6 19 44 11 32 10 28 58 10.5 34 15 28 58 10.5 34 20 28 63 10.5 39 25 49 89 12.5 41 32 52 99 11.5 43 40 51 99 10.5 43 Note) The dimensions above show the minimum necessary space for the replacement of the shock absorber and bumper bolt. (Full length of the stopper + 10mm) 2.
No.SQ1000V-OMQ0002-B 25 No.SQ1000V-OMQ0002-B 26 No.SQ1000V-OMQ0002-B 27 No.SQ1000V-OMQ0002-B 28 No.SQ1000V-OMQ0002-B 29 No.SQ1000V-OMQ0002-B 30 No.SQ1000V-OMQ0002-B 31 No.SQ1000V-OMQ0002-B 32 No.SQ1000V-OMQ0002-B 33 No.SQ1000V-OMQ0002-B 34 No.SQ1000V-OMQ0002-B 35 No.SQ1000V-OMQ0002-B 36 No.SQ1000V-OMQ0002-B 37 No.SQ1000V-OMQ0002-B 38 No.SQ1000V-OMQ0002-B 39 No.SQ1000V-OMQ0002-B 40 No.SQ1000V-OMQ0002-B 41
Auto Switch Rotation range / Actuation / most sensitive position D-M9 auto switch D-F8 auto switch Size Rotating Operation Operation A B angle Hysteresis Hysteresis angle angle (mm) (mm) angle angle m m 90 20.5 16.5 05 46 10 20 10 180 23.2 19.2 90 22.4 18.4 1 41 10 15 10 180 25.6 21.6 Operating angle m: Value of the operating range Lm of a single auto switch converted to an axial rotating
This may cause a malfunction due to an increase in sliding resistance, or use a freely moving connector (such as a floating joint). 41 - 7.3 Handling Caution 1. When the pushing operation is used, be sure to set to [Pushing operation]. Also, do not hit the workpiece in positioning operation or in the range of positioning operation. It may damage and malfunction.
) External seal (maintenance part) Heater (option) Pilot port (Pressurized / Totally closed) Axial seal (material : FKM) Scraper (Material : FKM) Valve (material : SUS304) Valve seal (maintenance part) Body(material: A6063) C D C E E (KF Flange) Fn J H B G A Unit: mm A Model A B C D E Fn G H J XLG-16 40 110 38 1 30 17 40 26 XLG-25 50 120 48 1 12 40 26 39 27.5 XLG-40 65 171 66 2 11 55 41
MHY2-16D 33 Pin hole positioning 12 4 15 2 x M4 x 0.7 thread depth 5 4 x M3 x 0.5 through (Mounting thread) (Thread for mounting attachment) 8 0.005 0.025 3H9 + 0.025 depth 3 0 5 4 7 4 x M4 x 0.7 thread depth 8 (Mounting thread) 2 x M4 x 0.7 thread depth 8 (Limted area for mounting attachment) 14 (Mounting thread) 2 x 4.5 through (Mounting hole) 30 38 28 28.5 30 20 17H9 + 0.043 depth 1.5 0 41
MLGPL (Ball bushing bearing) Dimensions A, DB, E: MLGPM (Slide bearing) A E A E Bore size (mm) 131 141.5 144.5 Bore size (mm) 115 128 131 DB DB st 50 50 < st 200 200 < st 350 200 < st 350 20 25 25 st 50 50 < st 200 74 89 84 st 50 50 < st 100 100 < st 200 200 < st 350 16 20 20 st 50 50 < st 100 100 < st 200 200 < st 350 74 89 84 40 50 63 40 50 63 31 34.5 29.5 174 196 199 36 46 41