SMC Corporation of America
Elite Part Number Search
Search Results "ISE20B-T-M5-S"

Body Size: 2 (M5), Socket, Plug Type: S (Socket), Port Size: M5 (M5 X 0.8), Connection: F (Female Thread)

Body Size: 2 (M5), Socket, Plug Type: S (Socket), Port Size: M5 (M5 X 0.8), Connection: M (Male Thread)

Body Size: 1 (M5 x 0.8, 10-32UNF), Type: 2 (Elbow), Control Type: 0 (Meter-out), Indicator Direction: None (0°), Thread: R, Port Size: M5 (M5 x 0.8), Width Across Flats: 9mm, Tubing: 04 (ø4), Seal: S (w/Sealant)

Body Size: 1 (M5 x 0.8, 10-32UNF), Type: 2 (Elbow), Control Type: 0 (Meter-out), Indicator Direction: None (0°), Thread: R, Port Size: M5 (M5 x 0.8), Width Across Flats: 9mm, Tubing: 06 (ø6), Seal: S (w/Sealant)

While the part number “AS1201F-M5-06A” is indeed viable, “AS1201F-M5-06SA” is not. The “S” is for sealant on the tapered male pipe threads. As the port size of the AS1201F is M5, which is a parallel thread (metric coarse thread), there is no sealant because it uses a gasket seal.

Body Size: 1 (M5 X 0.8, 10-32UNF), Type: 2 (Elbow), Control Type: 0 (Meter-out), Thread Type: R, Port Size: M5 (M5 X 0.8), Dimension, Across Flat [H]: Body Size 1: 9mm; Body Size 2, 3, 4 None, Applicable Tubing O.D.: Ø6, Seal Method: S (with Sealant)

Body Size: 1 (M5 X 0.8, 10-32UNF), Type: 2 (Elbow), Control Type: 0 (Meter-out), Thread Type: R, Port Size: M5 (M5 X 0.8), Dimension, Across Flat [H]: Body Size 1: 9mm; Body Size 2, 3, 4 None, Applicable Tubing O.D.: Ø4, Seal Method: S (with Sealant)

Body Size: 1 (M5 X 0.8, 10-32UNF), Type: 2 (Elbow), Control Type: 0 (Meter-out), Thread Type: R, Port Size: M5 (M5 X 0.8), Dimension, Across Flat [H]: E (8mm), Applicable Tubing O.D.: Ø4, Seal Method: S (with Sealant)

Body Size: 1 (M5 X 0.8, 10-32UNF), Type: 2 (Elbow), Control Type: 1 (Meter-in), Thread Type: R, Port Size: M5 (M5 X 0.8), Dimension, Across Flat [H]: Body Size 1: 9mm; Body Size 2, 3, 4 None, Applicable Tubing O.D.: Ø6, Seal Method: S (with Sealant)

Body Size: 1 (M5 x 0.8, 10-32UNF), Type: 3 (Universal), Control Type: 0 (Meter-out), Control Range: FM (1 to 50 mm/s), Indicator Window Direction: 0° , or None for FC, FM, Thread: R, Port Size: M5 (M5 x 0.8), Width Across Flats [H]: 9mm or None for Body Size 2, Tube Size: 06 (ø6), Sealant: without Sealant, Push lock: A (Push-lock)

The ISE2 series is a compact, pressure switch (for positive pressure) and can be integrated with ZX or ZR vacuum systems. The ISE2 series pressure switch has a quick response time of 10mS and the plug connector option makes wiring easy and simple., DIGITAL PRESSURE SWITCH, PRESSURE SWITCH, ISE1-6, N59, 45.00000 lb

Ce priphrique a galement t valu et dmontr conforme aux limites d'exposition aux RF d'IC dans des conditions d'exposition des appareils mobiles (antennes sont suprieures 20 cm partir du corps d'une personne). When product comply with IFETEL inquire below warming statement has to be contained in user manual.

Dynamic viscosity [m2/s] Viscosity [Pas] Density [kg/m3] Formulas below can be used for common units 1cP = 1mPas = 10-3Pas 1cSt = 1mm2/s = 10-6m2/s 13 Working Principle 1. When air is supplied, it passes through the switching valve and enters drive chamber B. 2.

Grease pack part number: GR-S-010 (10g), GR-S-020 (20g) Apply plenty of grease to the internal and external circumference of a new rod seal for replacement (See Table 4, P19). Fill the groove with grease. Refer to Page 21 for made to order product (XC85, X446). c) Mounting Mount taking care that the rod seal is in the right direction.

Grease weight GR-S-010 10g GR-S-020 20g -15- Basic Circuit for Cylinder Operation The basic circuit for operating the product with air filter, regulator, solenoid valve and speed controller (meter-out) is shown in the following figure. It is possible to use a quick exhaust. Regulator Air source Speed controller Air filter Solenoid valve .

Move Speed Position Accel PushingF T riggerL V PushingSp Moving F Area1 Area2 In posn mm/s2 mm/s mm mm/s2 mm/s mm mm mm 0 Absolute 100 20.00 1000 1000 0 0 0 100 18.00 22.50 0.5 1 Absolute 50 10.00 1000 1000 70 60 5 100 6.0 12.0 1.5 63 Absolute 20 5.00 500 500 0 0 0 100 3.0 8.0 1.2 6.

Grease pack part number: GR-S-010 (10g), GR-S-020 (20g) 3-3. Replacement Parts Refer to the catalog the parts that can be replaced. Warning 1) Maintenance should be performed according to the items above.

S SI unit Abbreviation of serial interface unit. A unit connected to a PLC to communicate input and output data. T Topology Connection configuration of the network : Supported by the product version "Device Revision 2.1" manufactured in March 2013 or later.

Symbol Double acting How to Order D 20 MHC2 Y59A S Number of auto switches Single acting Angular style air gripper 2 1 S Bore size 10mm 10 Action Double acting D Single acting S 16mm 16 20mm 20 25mm 25 Caution Be sure to read before handling.

ON-flow 0.01 /2B, 6 11/2B, 21 0 0 0.2 0.4 0.6 0.8 1.0 Pressure (MPa) 1 2 3 4 5 Flow speed (m/s) Precautions Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Be sure to read before handling.