(Example) 40D-A3C-4, 63D-A3C-6, 100D-A3C-10 50D-A3C-5, 80D-A3C-8 1.08 0.32 0.38 0.38 0.73 Double knuckle Accessory bracket 0.19 0.05 0.05 0.05 0.14 Knuckle pin 10-12-49 7 Series CE2 Dimensions: 40 to 100 RC 1/4 Pressurized locking port RC P Rod side cylinder port RC P Head side cylinder port Basic style RC 1/4 Unlocking port Unlocked when pressurized 7 (6 core twisted pair shielded wire)
A (mm) M Max. operating tension and compression power (kN) Maximum screwed depth P Allowable eccentricity U A B C D E F G H Bore Model Nominal thread dia.
Besides, the overall length is longer than the cylinder with air cushion as follows, because the bumpers are attached to the both sides of the piston: 32, 40: +6 mm, 50, 63: +8 mm, 80, 100: +10 mm. 32 40 50 63 80 100 90 90 102 102 124 124 164 200 200 141 145 164 Stroke range Bore size (mm) Effective thread length Width across A D Ee11 F G H MB J K MM N P S V W ZZ C B flats 19.5 27 32 32
Symbol Bore size (mm) A A' B B' D E F GA GB H J R MM FC NN FT FX FY FZ 6 7 9 14 14 3 10.5 8 6 6 17 6 7 M3 x 0.5 3.4 M10 x 1.0 1.6 24 16 32 10 10 12 15 17 5 13 8 6 7 20 7 8 M4 x 0.7 4.5 M12 x 1.0 1.6 28 18 37 15 12 14 20 19 6 15.5 10 6 7 24 9 10 M5 x 0.8 5.5 M14 x 1.0 2.3 36 22 49 Symbol S Z With auto switch W Bore size (mm) 5 st 10 st 15 st 20 st 30 st 5 st 10 st 15 st 20 st 30 st FI P
-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com (KB) D-A7/A8 Auto switch KA A + Stroke B + Stroke W L S EA EB EC M J 2 x 2-OA 2 x 2-RA Both ends tapped style (CQMA) (mm) Without auto switch With auto switch Stroke range (mm) Bore size (mm) P P EA EB EC B F Q A B F Q A TN TF NN NN TN TF 5 5.5 11.5 M5 x 0.8 M5 x 0.8 40 23 32 10 to 50 50 33
S 55 58 60 74 75 P M5 x 0.8 Rc 1/8 Rc 1/8 Rc 1/4 Rc 1/4 NY 26 28 36 42 46 NX 6 6.5 8 10 11 NC 7.5 depth 4.5 9 depth 5.5 10.5 depth 6.5 13.5 depth 8.5 17 depth 10.5 MM M10 x 1.25 M12 x 1.25 M14 x 1.5 M18 x 1.5 M18 x 1.5 NS 43 45 44 54 53 N 14 15.5 16 21.5 21.5 KA 10 12 14 18 18 ND M5 x 0.8 M6 x 1 M8 x 1.25 M10 x 1.5 M12 x 1.75 NE 4.3 5.1 6.9 8.7 10.5 ZZ 69 72 75 92 96 Model MUB25 MUB32 MUB40
With auto switch Without auto switch B A B D Stroke range Bore size (mm) BP C E F G H I J K L M N Q O OA OB P RA RB S T U V Z A 82 36 10 to 50 Rc 1/8 15.6 14 Rc 1/4 63 16.5 46 92 8 1.6 15 20 38 M10 x 1.5 103 17 60 M8 x 1.25 53 16 4.2 47.5 19 93 7 9 10.5 77 92 46 depth 12 depth 10.5 75, 100 96.5 43.5 10 to 50 19.6 17.5 Rc 3/8 Rc 1/4 80 106.5 53.5 18.5 10 2 21 25 43 M16 x 2.0 132 22 77 M10
Mechanically Jointed Rodless Cylinder/Linear Guide Type Construction Series MY1H 10 Replacement Procedure is P.310 Centralized piping type: 10 Actuators Modular F.R.L. Pressure Control Equipment Air Preparation Equipment Industrial Filters Replacement Procedure Actuators Modular F.R.L. Pressure Control Equipment Industrial Filters !8 !6 !7 !4 !9 !
Supply(P),Vacuum(V), One-touch Fitting: Supply (P) Port: ø6; Vacuum (V) Port: ø12, Exhaust Type: P (Rc 1/2 Port Exhaust), Supply/Release Valve Combination: K1 [Supply Valve (N.C.), Release Valve (N.C.)], Rated Voltage: 5 (24 VDC), Electrical Entry: L (L Plug Vertical Connector w/Lead Wire 300mm), Light/Surge Voltage Suppressor: Z (w/Light/Surge Voltage Suppressor), Manual Override: Non-locking
Suction Flow Rate: 300 L/min (ANR), Supply Pressure: H (0.50 MPa), Vacuum (2/V) Port Size/Supply (1/P) Port Tubing O.D: N06 [Vacuum: NPT3/4; Supply: 5/16" (Inch)], Exhaust Method: P (Port Exhaust, Rc1, G1, NPT1), Supply Valve/Release Valve Combination: w/o Valve, Rated Voltage: None, Electrical Entry: None, Light/Surge Voltage Supprressor: None, Manual Override: E (Push-turn Locking Lever
Compatible motor Actuator part number P Step motor (Servo/24 VDC) (Except cable specifications and actuator options) Example: Enter LEMB25T-300 for the LEMB25T-300W-S12N1.
Reduced maintenance (No need for control or replacement) Positioning repeatability: 0.01 mm*3 *1 Compared with the LEFS *2 Size 40, Mep, Overhang: 300 mm *3 Excludes the lead H Step Motor Controller JXC Series p. 3 Battery-less Absolute Type (Step Motor 24 VDC) MDirect input type
Compact Guide Cylinder/With Air Cushion Series MGP Replacement Procedure is 12, 16, 20, 25, 32 40, 50, 63, 80, 100 P.333 Construction MGPM12 to 25 MGPM32 to 100 @6 @4 @4 @6 @7 @5 @5 @7 The numbers are the same as the "Construction" of the Best Pneumatics No.3 Series MGP. *BLUE links will lead to purchase pages. Replacement Parts: Seal Kit Kit no.
Seal kit for maintenance of the CLKQG P series with lock is not available. Consult SMC for maintenance service. Seal kit for maintenance of the CLKQG P series with lock is not available. Replacement Parts: Grease Pack Replacement Parts: Grease Pack Grease pack part no. Content Grease pack part no.
Seal kit for maintenance of the CLKQG P series with lock is not available. Consult SMC for maintenance service. Seal kit for maintenance of the CLKQG P series with lock is not available. Replacement Parts: Grease Pack Replacement Parts: Grease Pack Grease pack part no. Content Grease pack part no.
Seal kit for maintenance of the CLKQG P series with lock is not available. Consult SMC for maintenance service. Seal kit for maintenance of the CLKQG P series with lock is not available. Replacement Parts: Grease Pack Replacement Parts: Grease Pack Grease pack part no. Content Grease pack part no.
Seal kit for maintenance of the CLKQG P series with lock is not available. Consult SMC for maintenance service. Seal kit for maintenance of the CLKQG P series with lock is not available. Replacement Parts: Grease Pack Replacement Parts: Grease Pack Grease pack part no. Content Grease pack part no.
Hygienic Design Cylinder/ISO Standard Type Series HYC 32, 40, 50, 63 Replacement Procedure is P.297 Hygienic Design Cylinder/ISO Standard Type Construction Hygienic Design Cylinder/ISO Standard Type Series HYC 32, 40, 50, 63 Series HYC 32, 40, 50, 63 Replacement Procedure is Replacement Procedure is !6 !5 !8 !7 !9 @1 P.297 P.297 Construction Construction !6 !5 !8 !7 !9 @1 !6 !5 !8 !7 !
Pressure Control Equipment Industrial Filters Replacement Procedure is P.301 20, 25, 32 40, 50, 63 !7 !5 !6 !8 P.301 Construction Construction Actuators Modular F.R.L. Pressure Control Equipment Air Preparation Equipment Industrial Filters Replacement Procedure Actuators Modular F.R.L. Pressure Control Equipment Industrial Filters !7 !5 !6 !8 Actuators Modular F.R.L.
-X14 424 Ionizer IZS40/41/42 Series Specifications IZS41(NPN) IZS41-P (PNP) IZS42(NPN) IZS42-P (PNP) IZS40 Ionizer model Dual AC 6,000 V AC, DC Corona discharge type Ion generation method Method of applying voltage Applied voltage Offset voltage Note) AC, Sensing AC, DC 7,000 V IZS IZS Within 30 V Air (Clean dry air) 0.5 MPa or less 0.7 MPa 6, 8, 10 Fluid Operating pressure Proof pressure