SMC Corporation of America
Elite Part Number Search
Search Results "CDQ2B80-45+0DM-XC11"

Series CJ2 is auto switch capable Double acting, single rod, end lock cylinder, 16mm bore, Mounting types: basic, axial foot, front flange, double clevis, Standard strokes *: 15, 30, 45, 60, 75, 100, 125, 150, 175, 200, Auto switch capable, Air Cylinder with End Lock, ROUND BODY CYLINDER, 353, 0.021 lb

XLA-16-2 XLA-25-2 XLA-40-2 XLA-50-2 XLA-63-2 XLA-80-2 16 25 40 50 63 80 5605150 -6 Pa(abs) 110 l/s 1 5 14 45 80 160 200 10 FKM1.310 3/s Pam -11 FKM1.310 KFNW KFNW KDN SUS316L,SUS304,FKM MPa(G) 0.40.7 3 2 0.5MPa 31 61 220 390 680 1420 cm M5 Rc1/8 kg 0.28 0.47 1.1 1.7 3.1 5.1 1 21 9 XL-OMY0001 4-2 XLA-25-2 XLA-40-2 XLA-50-2 AC90240V XL1A25-60S-1 XL1A25-60S-1 1 1 H4 AC100V 200

XLC-16 XLC-25 XLC-40 XLC-50-1 XLC-63-1 XLC-80-1 XLC-100-1 XLC-160-1 16 25 40 50 63 80 100 160 560(5150) -5 Pa (abs) 110 l/s 1 5 14 45 80 160 200 300 800 10 (FKM) 1.310 Pam 3/S -11 (FKM) 1.310 KF(NW) KF(NW)K(DN) SUS316LSUS304FKM() 2 MPa (G) 0.30.6 0.40.6 cm 3 3 0.5MPa 38 91 430 280 500 1000 2300 3700 M5 Rc 1/8 Rc1/4 kg 0.28 0.46 1.1 1.4 2.3 4.0 8.7 14.5 1) 2) Y-VAC2 3) 1 7 XL-OMV0002

Chemraz VALQUA.CO.JP R ULTIC ARMOR 25 40 50 63 80 100 160 H4100 XLA25-60S-1 XLA25-60S-1 XLA25-60S-2 XLA25-60S-3 XLA25-60S-2 XLA25-60S-2 (2 ) (3 H5120 XLA25-60S-1 XLA25-60S-2 XLA25-60S-2 XLA25-60S-3 XLA25-60S-2 XLA25-60S-2 XLA25-60S-2 2 3 4 XLD-80H5 2 XLA25-60S-2 8 XL-OMY0002 4. 4-1 XLD-25 XLD-40 XLD-50 XLD-63 XLD-80 XLD-100 XLD-160 25 40 50 63 80 100 160 [] 5605150 -6 Pa abs 110 14 45

XLH-16 XLH-25 XLH-40 XLH-50 16 25 40 50 5150 -6 Pa (abs) 110 l/s 1 5 14 45 80 10 FKM1.310 3/s Pam -11 FKM1.310 KFNW SUS316L,FKM Nm 0.1 0.15 0.35 0.5 5 7 10 13 0.23 0.41 1.05 1.62 1) 3-2.

Usable stroke by buckling strength Usablestroke by Mounting style buckling strength (cm) Pressure Symbol and sketch (MPa) Symbol of bracket Rod side Frang e F Head side flange 103 92 113 Foot: 79 70 86 L G 66 58 72 45 38 47 33 27 34 26 22 27 96 83 106 Center Clevis trunnion 71 61 76 CD T 59 50 62 135 119 147 101 89 111 84 74 91 Rod side Frang e F Head side flange 301

MXQA-A1687 MXQ16B MXQB-A1687 MXQ20(A) MXQA-A2087 MXQ20B MXQB-A2087 MXQ25(A) MXQA-A2587 )MXQ6B MXQ6(C) Nm MXQ6(A) RJ0603 0.85 MXQ8(A,C) MXQ6B RJ0603 0.85 MXQ12(A,C) MXQ8B RJ0805 1.67 MXQ16(A) MXQ12B RJ1006 3.14 MXQ20(A) MXQ16B RJ1007H 3.14 MXQ25(A) MXQ20B RH1410 10.8 12 2-8 kg RJ MXQ6(A) 0.6 0.6 0.6 MXQ8(A,C) 1 1 1 1 MXQ12(A,C) 2 2 2 1 MXQ16(A) 4 4 4 2.5 MXQ20(A) 6 6 6 5 MXQ25(A) 9 9 9 5.5 2 45

60204-1: Safety of machinery -Electrical equipment of machines (Part1:General requirements) ISO 10218-1992: Manipulating industrial robots -Safety JIS B 8370: JIS B 8361: JIS B 9960-1: -(1:) JIS B 8433-1993: *2) 1. 2. 3. 1. 2. 3. 4.2 MGP series 113) 3) 1 1 () 4 2 T (d=) 2 T 2 2 RSQ 400mm (mm) 3 1mm MGPM MGPL (mm) MGPS (mm) (mm) 10% 25% 140% (/MGPM50) MGPS MPGM 50 30 25 80 45

Fig. 11 Proper auto switch mounting position at rotation end Table 13 Auto Switch Rotation range / Actuation / most sensitive position A Operation range at optimum set position (Lm/2) Most sensitive position Auto switch operating range Lm Fig. 12 Reed switch Solid state switch Size Rotation Operation Operation Hysteresis Hysteresis A B range A B range range range m m 10 190 27 45 53 10 or

MHL2-20D2 100 162 262 1,690 MHL2-25D 60 50 100 150 1,690 MHL2-25D1 100 182 282 2,560 25 40 MHL2-25D2 120 200 320 2,775 MHL2-32D 30 70 150 220 2,905 MHL2-32D1 120 198 318 3,820 32 20 MHL2-32D2 160 242 402 4,655 MHL2-40D 30 100 188 288 5,270 MHL2-40D1 160 246 406 6,830 40 20 MHL2-40D2 200 286 486 7,905 ) (mm) 10 16 20 25 32 40 (MPa) 0.15~0.6 0.1~0.6 () -10~60 (mm) 0.1 () (N) 0.5MPa 14 45

SETTING 1 No. 1 0.00mm 1 SET <1> -7- 50mm30mm 50mm TEST MONITOR DATA 1 No. 0 50.00mm 250mm/s 1 No. 0 50 .00mm 250mm/s ALARM JOG SETTING 30 SET __ DATA SET <> MENU (5) 1 No. 0 30 .00mm 250mm/s 3.3[]P21P24 -8- 2. 2.1 LEF/ (1)(DC24V) LEFS16 LEFS25 LEFS32 (mm) 1) 100,200,300,(400) 100,200,300,(400),500,(600) 100,200,300,400 500 (600,700,800) 9 10 20 20 40 45

/LEHS .20 4.1 . 20 4.2 . 21 4.3 . 22 5.23 5.1 . 23 5.2 . 24 5.3 . 27 . 27 . 29 (1). 31 (2). 32 (3). 33 . 34 5.4 . 36 . 36 . 38 1 - 6.39 7.40 7.1 . 40 7.2 . 41 7.3 . 41 7.4 . 42 7.5 . 44 7.6 . 44 8.45 8.1 . 45 8.2 . 46 8.3 . 50 8.4 . 53 .54 2 - LEH Series / (ISO/IEC)(JIS)1) 2) *1) ISO 4414: Pneumatic fluid power -General rules relating to systems ISO 4413: Hydraulic fluid power -General

44- Para protect Para protect 12 1+(++) 2(+) Enable SW Enable SW 12 SW 1 2 Unit name Unit name () W-AREA1 W-AREA1 (-) (+) WAREA ON (mm) W 1W 2 WAREA ON *W 1W 2 PARA W 1=W 2=0 WAREA OFF) W-AREA2 W-AREA2 (-) (+) ORG Correct Link Offset () Sensor type Sensor type () Option 1 Option 1 () Undefine No. 11 Undefine No. 11 () Undefine No. 12 Undefine No. 12 () *1 -45

-COM4 40 1) +COM1+COM2 +COM3+COM4 I/O2 +COM1+COM2 +COM3 +COM4 DC24V 24V -COM1-COM2-COM3-COM4 OUT -COM DC24V 0V 45 No.SFOD-OMT0009CN-B (2) PNP I/O 1 DC24V OUT0 10 +COM1 1 OUT1 30 +COM2 21 OUT2 11 IN0 2 OUT3 31 IN1 22 OUT4 12 IN2 3 OUT5 32 OUT6 13 IN3 23 OUT7 33 IN4 4 OUT8 14 IN5 24 BUSY 34 IN6 5 (OUT9) IN7 25 AREA 15 (OUT10) IN8 6 SETON 35 IN9 26 INP 16 IN10 7 SVRE 36

) 00h*3 10.1.2 (1)[ ](P.40) 70 1 7 DATA(L) F8 2 70 3 10.1.2 (1)[ ](P.40) F8 4 8 9.5.1 (P.30)RWw1 Sub Function 80h OR() 9 F0 Sub Function *3 10 F0 Address 9.5.1 (P.30)00h*3 11 F0 Address (0) 0 12 F0 DATA(H) *3 13 F0 DATA(L) 00h *3 14 F0 15 F0 H= L= *3 RWr3: Sub Function (RWr9) RWw1Sub Function80hOR() RWr6:DATA(H)(RWr12)RWr4:AddressRWr7:DATA(L)( RWr10RWr13)00h 2 1) 2) () 3 45

Large size series tolerant of high temperature environment , Air-cooled type can be used at 45°C ambient temperature; exhausting direction can be selected from 4 layouts, Water-cooled type reduces amount of facility water; piping port can be selected from 2 directions, Refrigerant: R407C (HFC), REFRIGERATED AIR DRYER, REFRIGERATED AIR DRYER, IDF, IDFB, 761, 270 lb

Accepts nylon and urethane tubes, Applicable for both vacuum and positive pressure applications, Release collar allows easy removal of tubing without damaging the tube, Maximum vacuum pressure of 1.0MPa, FITTING, 45 DEG MALE ELBOW, ONE-TOUCH FITTING, 949, 4.6 lb

Accepts nylon and urethane tubes, Applicable for both vacuum and positive pressure applications, Release collar allows easy removal of tubing without damaging the tube, Maximum vacuum pressure of 1.0MPa, FITTING, 45 DEG MALE ELBOW, ONE-TOUCH FITTING, 949, 3 lb

10%, Ripple (p-p) 10% or less (with power supply polarity protection)45 mA or lessNPN or PNP open collector 2 outputs (Selectable)80 mA28 V (at NPN output)1 V or less2.5 ms (with anti-chattering function: 20, 100, 500, 1000, 2000 ms)Yes?0.2% F.S. ?1 digitVariable (0 or above) Note 1)Variable (0 or above) Note 1)1 to 5 V ?2.5% F.S.?1% F.S. or lessApprox. 1 k 4 to 20 mA ?2.5% F.S.?